Search results for "myopia"

showing 10 items of 165 documents

Femtosecond laser versus mechanical microkeratome laser in situ keratomileusis for myopia: Metaanalysis of randomized controlled trials.

2011

Purpose To examine differences in efficacy, accuracy, safety, and changes in aberrations between femtosecond and mechanical microkeratome laser in situ keratomileusis (LASIK) for myopia. Setting Department of Ophthalmology, Shanghai First People's Hospital Affiliated to Shanghai Jiaotong University, Shanghai, China. Design Evidence-based manuscript. Methods Data sources, including PubMed, Medline, EMBASE, and Cochrane Controlled Trials Register, were searched to identify potentially relevant prospective randomized controlled trials. Primary outcome measures were efficacy (uncorrected distance visual acuity ≥20/20), accuracy (±0.50 diopter mean spherical equivalent), and safety (loss of ≥2 l…

Adultmedicine.medical_specialtyCorneal Wavefront Aberrationgenetic structuresDatabases Factualmedicine.medical_treatmentCorneal StromaKeratomileusis Laser In SituVisual AcuityKeratomileusisRefraction OcularSensitivity and Specificitylaw.inventionYoung AdultPostoperative ComplicationsRandomized controlled triallawMicrokeratomemedicineMyopiaHumansRegistriesDioptreRandomized Controlled Trials as TopicEquipment Safetybusiness.industryLASIKReproducibility of ResultsOdds ratioMiddle Agedeye diseasesSensory SystemsConfidence intervalSurgeryOphthalmologyTreatment OutcomeMeta-analysisSurgeryLasers ExcimerbusinessJournal of cataract and refractive surgery
researchProduct

Effects of LASIK on Corneal Endothelium Using the 15-kHz IntraLase Femtosecond Laser

2011

PURPOSE: To assess the effects of LASIK with the 15-kHz IntraLase femtosecond laser on corneal endothelium. METHODS: In a prospective, single-center clinical trial, 138 patients (mean age: 32.0±7.1 years [range: 21 to 42 years]) underwent femtosecond LASIK for the correction of myopia −0.75 to −9.00 diopters (D) and cylinder up to 3.25 D. Patients were divided into two groups: contact lens group (n=76) and non-contact lens group (n=62). Pre- and 12-month postoperative specular microscopy of the central corneal endothelium was performed. The integrity of the central endothelium was assessed in terms of endothelial cell density and percentage of hexagonality. RESULTS: In the contact lens gro…

Adultmedicine.medical_specialtyCorneal endotheliumgenetic structuresEndotheliummedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityCell CountKeratomileusisRefraction OcularYoung AdultOphthalmologyMyopiamedicineHumansProspective StudiesDioptrebusiness.industryEndothelium CornealLASIKCorneal Endothelial Cell LossContact Lenses Hydrophiliceye diseasesSurgeryContact lensOphthalmologymedicine.anatomical_structureLens (anatomy)FemtosecondLasers ExcimerSurgerysense organsbusinessJournal of Refractive Surgery
researchProduct

Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.

2007

Purpose To evaluate variations in the position of the phakic iris claw lens (Artisan®, Verisyse®) and the natural crystalline lens during the accommodation process. Methods We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master®/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. Results There was a forward shift of the phakic iris claw lens with a mean of 70 μm (8–178 μm) of the optical path length (OPL). At the same time…

Adultmedicine.medical_specialtyPhakic Intraocular LensesMaterials scienceBiometrymedicine.medical_treatmentIrisIntraocular lensRefraction OcularMyopic astigmatism03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinemedicineMyopiaHumansIris clawOptical path lengthbusiness.industryHigh myopiaAccommodation OcularAstigmatismGeneral MedicineMiddle AgedOphthalmologymedicine.anatomical_structureLens (anatomy)030221 ophthalmology & optometrybusinessAccommodation030217 neurology & neurosurgeryTomography Optical CoherenceCoherence (physics)Follow-Up StudiesEuropean journal of ophthalmology
researchProduct

Femtosecond laser versus mechanical keratome LASIK for myopia.

2005

To assess efficacy, safety, predictability, stability, and changes in corneal higher-order aberrations (CHOAs) and contrast sensitivity (CS) after a femtosecond laser for LASIK and standard LASIK for myopia.Prospective, randomized, comparative clinical study.Two hundred eyes of 100 consecutive patients who underwent LASIK treatment using the VISX S2 laser system. A femtosecond laser for flap creation was used in 100 eyes (50 patients; spherical equivalent [SE], -2.85+/-1.79 diopters [D]), and a mechanical microkeratome was used in 100 eyes (50 patients; SE, -2.90+/-1.63 D).Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity (BSCVA), manifest refraction, CS by means of t…

Adultmedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisSurgical FlapsContrast SensitivityCorneaTonometry OcularMicrokeratomemedicineMyopiaHumansProspective StudiesDioptremedicine.diagnostic_testbusiness.industryLasersLASIKCorneal Topographymedicine.diseaseCorneal topographyeye diseasesPhotorefractive keratectomySurgeryOphthalmologyTreatment Outcomesense organsmedicine.symptombusinessOphthalmology
researchProduct

Chromatic and achromatic visual fields in relation to choroidal thickness in patients with high myopia: A pilot study

2018

Purpose. - To analyse the relationship between the choroidal thickness and the visual perception of patients with high myopia but without retinal damage. Methods. - All patients underwent ophthalmic evaluation including a slit lamp examination and dilated ophthalmoscopy, subjective refraction, best corrected visual acuity, axial length, optical coherence tomography, contrast sensitivity function and sensitivity of the visual pathways. Results. - We included eleven eyes of subjects with high myopia. There are statistical correlations between choroidal thickness and almost all the contrast sensitivity values. The sensitivity of magnocellular and koniocellular pathways is the most affected, an…

Adultmedicine.medical_specialtyVisual perceptiongenetic structuresColorPilot ProjectsVisual systemSeverity of Illness IndexContrast SensitivityOphthalmoscopyYoung Adult03 medical and health sciences0302 clinical medicineOptical coherence tomographyOphthalmologyHigh myopiaMyopiamedicineHumansMotion perceptionContrast sensitivityColor Perception TestsColor Visionmedicine.diagnostic_testVisual pathwayChoroidbusiness.industryOrgan SizeMiddle AgedSubjective refractioneye diseasesVisual fieldOphthalmoscopyOphthalmologyKoniocellular cellChoroidal thickness030221 ophthalmology & optometrysense organsVisual FieldsbusinessVision fieldColor PerceptionTomography Optical Coherence030217 neurology & neurosurgery
researchProduct

Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes.

2004

Abstract Purpose: To evaluate the change in contrast sensitivity after implantation of the Verisyse toric phakic intraocular lens (IOL) (AMO) for the correction of myopia with astigmatism. Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods: Eighteen eyes had implantation of an iris-supported toric phakic IOL to correct myopia with astigmatism. The mean preoperative spherical equivalent was −12.65 diopters ± 3.6 (SD). The contrast sensitivity with best spectacle correction was determined before surgery and 3 months after surgery using the CSV-1000 HGT instrument (Vector Vision Inc.). Results: Three months after IOL implantation, the mean contrast sen…

Adultmedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectAstigmatismPhakic intraocular lensProsthesis DesignCycles per degreelaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineMyopiaContrast (vision)HumansPhakic iolIris clawDioptremedia_commonLenses Intraocularbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologySurgerysense organsbusinessJournal of cataract and refractive surgery
researchProduct

Prevalence and Time Trends in Myopia Among Children and Adolescents.

2020

Background Myopia (near-sightedness) is increasing worldwide, especially in Asia. The aim of this study was to describe trends in the prevalence of myopia in Germany. Methods We analyzed data from the German Health Interview and Examination Survey for Children and Adolescents (KiGGS; baseline survey 2003-2006, N = 17 640; wave 2, 2014-2017, N = 15 023). The presence of myopia was determined from a parent questionnaire and validated by the use of a visual aid. The population prevalence of myopia was calculated. Based on the KiGGS wave 2 data, potential risk factors for myopia were identified by means of logistic regression. Results The prevalence of myopia at the age of 0-17 years in Germany…

Asiagenetic structuresAdolescentCross-sectional studyPopulationLogistic regression03 medical and health sciences0302 clinical medicineRisk FactorsGermany0502 economics and businessMyopiaPrevalenceMedicineHumansFamily historyeducationChildLetters to the EditorSocioeconomic statuseducation.field_of_studyInternetbusiness.industryTime trends05 social sciencesInfant NewbornInfantGeneral MedicineOdds ratioHealth SurveysConfidence intervaleye diseasesCross-Sectional StudiesChild Preschool030221 ophthalmology & optometry050211 marketingOriginal Articlesense organsbusinessDemographyDeutsches Arzteblatt international
researchProduct

Miopijas attīstību ietekmējošie faktori

2021

Darbs ir uzrakstīts latviešu valodā uz 36 lappusēm. Tajā kopā ir 24 attēli un 11 tabulas. Darbā kopā ir 35 atsauces uz literatūras avotiem. Darba mērķis : Novērtēt faktorus, kuri ietekmē miopijas progresēšanu. Pētījuma ietvaros tika izveidotas divas aptaujas. Aptaujā iegūtie dati tika apkopoti no 71 respondenta. Lai salīdzinātu un analizētu aptaujā iegūto dalībnieku datus un noskaidrotu, kā miopija progresē, papildus tika izmantots arī miopijas kalkulators. Tā kā miopijas kalkulatora piedāvātajām miopijas progresiju līknēm ir informatīvs raksturs, tad bērnu vecākiem kopā ar acu ārstu vai optometristu miopijas kalkulators varētu palīdzēt pieņemt labāko lēmumu miopijas korekcijas izvēlē. Atsl…

Brien Holden Vision InstituteNational Myopia Institutemiopijas kalkulatorsFizikamiopija
researchProduct

Genome-wide meta-analyses of multiancestry cohorts identify multiple new susceptibility loci for refractive error and myopia

2013

Author version made available in accordance with the publisher's policy.

Candidate geneRefractive errorBone Morphogenetic Protein 2Genome-wide association studyVARIANTSGenomeGenome-wide association studies0302 clinical medicineRisk FactorsMyopiaGRIA4Genetics0303 health sciencesKCNQ Potassium ChannelsDisease geneticsEYE GROWTHASSOCIATIONRETINAL-PIGMENT EPITHELIUMRefractive ErrorsGenetic load3. Good healthADAPTED MOUSE RETINAMeta-analysisACIDPOTASSIUM CHANNELEXPRESSIONSingle-nucleotide polymorphismBiologyWhite PeopleArticle03 medical and health sciencesAsian PeoplemedicineGeneticsHumansGenetic Predisposition to DiseaseReceptors AMPAgene; myopia; refractive030304 developmental biologyHomeodomain Proteinsta1184ta3121medicine.diseaseGENEAlcohol OxidoreductasesSERINE-PROTEASEbiology.protein030221 ophthalmology & optometrySusceptibility locusTrans-ActivatorsEye disorderLamininSerine ProteasesGWAS; meta-analyses; refractive error; myopiaGenome-Wide Association StudyNature Genetics
researchProduct

Proposal of a new diffractive corneal inlay to improve near vision in a presbyopic eye

2020

[EN] A new class of diffraction-based corneal inlays for treatment of presbyopia is described. The inlay is intended to achieve an improvement of the near focus quality over previous designs. Our proposal is a two-zone hybrid device with separated amplitude and phase areas having a central aperture and no refractive power. An array of micro-holes is distributed on the surface of the inlay conforming a binary photon sieve. In this way, the central hole of the disk contributes to the zero order of diffraction, and the light diffracted by the micro-holes in the peripheral photon sieve produces a real focus for near vision. We employed ray-tracing software to study the performance of the new in…

DiffractionApertureComputer scienceVisual AcuityOptical powerRefraction OcularDiffraction efficiencyModels Biological01 natural sciencesCorneaCorneal Transplantation010309 opticsOpticsOptical transfer function0103 physical sciencesMyopiamedicine03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edadesHumansComputer SimulationElectrical and Electronic EngineeringEngineering (miscellaneous)Vision BinocularInlaymedicine.diagnostic_testbusiness.industryCorneal TopographyPresbyopiaPresbyopiaModels Theoreticalmedicine.diseaseCorneal topographyCorneal inlayAtomic and Molecular Physics and OpticsPhoton sieveIntraocular lensesFISICA APLICADAbusinessOrbital ImplantsApplied Optics
researchProduct