Search results for "near-infrared"
showing 10 items of 180 documents
Understanding and exploiting long-lived near-infrared emission of a molecular ruby
2018
Coordination chemistry reviews 359, 102 - 111 (2018). doi:10.1016/j.ccr.2018.01.004
Hyperspectral venous image quality assessment for optimum illumination range selection based on skin tone characteristics
2014
Background Subcutaneous veins localization is usually performed manually by medical staff to find suitable vein to insert catheter for medication delivery or blood sample function. The rule of thumb is to find large and straight enough vein for the medication to flow inside of the selected blood vessel without any obstruction. The problem of peripheral difficult venous access arises when patient’s veins are not visible due to any reason like dark skin tone, presence of hair, high body fat or dehydrated condition, etc. Methods To enhance the visibility of veins, near infrared imaging systems is used to assist medical staff in veins localization process. Optimum illumination is crucial to obt…
Microcirculatory Assessment of Arterial Below-Knee Stumps: Near-Infrared Spectroscopy Versus Transcutaneous Oxygen Tension—A Preliminary Study in Pro…
2017
International audience; Objective: To examine metrologic properties of near-infrared spectroscopy (NIRS) versus transcutaneous oxygen tension (TcPO2) for micro-circulatory assessment of vascular transtibial stumps at the stabilized period of prosthesis fitting, as a preliminary step before exploring its ability to predict stump healing, considering the previously identified limits of TcPO2 (borderline area between 15 and 35mmHg).Design: Prospective single-center observational study.Setting: University-based rehabilitation center.Participants: Individuals with unilateral transtibial amputation for peripheral artery disease, at the definitive stage of prosthesis fitting, able to perform a 2-m…
Central alterations of neuromuscular function and feedback from group III-IV muscle afferents following exhaustive high-intensity one-leg dynamic exe…
2015
The aims of this investigation were to describe the central alterations of neuromuscular function induced by exhaustive high-intensity one-leg dynamic exercise (OLDE, study 1) and to indirectly quantify feedback from group III-IV muscle afferents via muscle occlusion (MO, study 2) in healthy adult male humans. We hypothesized that these central alterations and their recovery are associated with changes in afferent feedback. Both studies consisted of two time-to-exhaustion tests at 85% peak power output. In study 1, voluntary activation level (VAL), M-wave, cervicomedullary motor evoked potential (CMEP), motor evoked potential (MEP), and MEP cortical silent period (CSP) of the knee extensor…
Reward motivation and neurostimulation interact to improve working memory performance in healthy older adults: A simultaneous tDCS-fNIRS study.
2019
Abstract Several studies have evaluated the effect of anodal transcranial direct current stimulation (tDCS) over the prefrontal cortex (PFC) for the enhancement of working memory (WM) performance in healthy older adults. However, the mixed results obtained so far suggest the need for concurrent brain imaging, in order to more directly examine tDCS effects. The present study adopted a continuous multimodal approach utilizing functional near-infrared spectroscopy (fNIRS) to examine the interactive effects of tDCS combined with manipulations of reward motivation. Twenty-one older adults (mean age = 69.7 years; SD = 5.05) performed an experimental visuo-spatial WM task before, during and after …
Robotic assisted prostatic surgery in the Trendelenburg position does not impair cerebral oxygenation measured using two different monitors: A clinic…
2014
Robotic assisted prostatic surgery is frequently used because of its reduced side-effects compared with conventional surgery. During surgery, an extreme Trendelenburg position and CO2 pneumoperitoneum are necessary, which may lead to cerebral oedema, can potentially reduce brain perfusion and therefore could impair cerebral oxygenation. Cerebral oxygen saturation can be measured non-invasively using near-infrared spectroscopy (NIRS).The hypothesis of the present study was that steep Trendelenburg positioning during robotic assisted prostatic surgery impairs cerebral oxygen saturation measured using two different NIRS monitors.Clinical observational study.Primary care university hospital, st…
Hemodynamic responses to speech and music in newborn infants
2009
We used near‐infrared spectroscopy (NIRS) to study responses to speech and music on the auditory cortices of 13 healthy full‐term newborn infants during natural sleep. The purpose of the study was to investigate the lateralization of speech and music responses at this stage of development. NIRS data was recorded from eight positions on both hemispheres simultaneously with electroencephalography, electrooculography, electrocardiography, pulse oximetry, and inclinometry. In 11 subjects, statistically significant (P < 0.02) oxygenated (HbO(2)) and total hemoglobin (HbT) responses were recorded. Both stimulus types elicited significant HbO(2) and HbT responses on both hemispheres in five subjec…
The effects of skin and core tissue cooling on oxygenation of the vastus lateralis muscle during walking and running
2016
Skin and core tissue cooling modulates skeletal muscle oxygenation at rest. Whether tissue cooling also influences the skeletal muscle deoxygenation response during exercise is unclear. We evaluated the effects of skin and core tissue cooling on skeletal muscle blood volume and deoxygenation during sustained walking and running. Eleven male participants walked or ran six times on a treadmill for 60 min in ambient temperatures of 22°C (Neutral), 0°C for skin cooling (Cold 1), and at 0°C following a core and skin cooling protocol (Cold 2). Difference between oxy/deoxygenated haemoglobin ([diffHb]: deoxygenation index) and total haemoglobin content ([tHb]: total blood volume) in the vastus lat…
Fabrication and characterization of tuned Gaussian mirrors for the visible and the near infrared
1988
A thin-film technique has been developed for vacuum fabrication of mirrors with Gaussian reflectivity profiles. Samples with diameters from 2 to 8 mm and assigned maximum reflectivities for visible or near-IR wavelengths have been made and their optical properties evaluated. By properly choosing both the geometry of the evaporation source and the masking system, one can obtain quasi-Gaussian or super-Gaussian reflectivity profiles.
Near-infrared radiative transfer modelling with different CH4 spectroscopic databases to retrieve atmospheric methane total amount
2011
International audience; Atmospheric methane content can be retrieved from measurements of solar radiation attenuated by the atmosphere in the near infrared spectral region where the space-borne and ground-based spectrometers carry out regular measurements. It is shown, in the present work, that the different spectroscopic databases can give significantly different results for both forward simulations of the atmospheric transmittance and the inverse problem solution to retrieve the CH4 total content in the atmosphere using spectra measured by ground-based FTIR spectrometer in the near infrared spectral region. These discrepancies and the problem of the reduction of their influence on the atm…