Search results for "nitric acid"
showing 10 items of 49 documents
Microwave-assisted vapour-generation Fourier transform infrared spectrometric determination of carbonate in waters
1998
Abstract A microwave-assisted vapour-generation Fourier transform infrared spectrometric procedure is proposed for the determination of total carbonate in waters. The method is based on the simultaneous injection of 100 μl of sample and 300 μl of 0.1 M nitric acid in a two-channel manifold with a merging zone; a coil located inside a microwave oven encourages the removal of CO 2 . The carbon dioxide is separated from the distilled water employed as carrier by means of gas–liquid separator and is introduced by a nitrogen carrier flow inside a long-path infrared absorption gas cell, from which the corresponding flow analysis recording is registered as a function of time in the wavenumber rang…
Determination of mercury in rice by cold vapor atomic fluorescence spectrometry after microwave-assisted digestion.
2010
Abstract A cold vapor atomic fluorescence spectrometry method (CV-AFS) has been developed for the determination of Hg in rice samples at a few ng g−1 concentration level. The method is based on the previous digestion of samples in a microwave oven with HNO3 and H2O2 followed by dilution with water containing KBr/KBrO3 and hydroxylamine and reduction with SnCl2 in HCl using external calibration. The matrix interferences and the effect of nitrogen oxide vapors have been evaluated and the method validated using a certified reference material. The limit of detection of the method was 0.9 ng g−1 with a recovery percentage of 95 ± 4% at an added concentration of 5 ng g−1. The concentration level …
GFAAS determination of selenium in infant formulas using a microwave digestion method.
1994
A method for determining the selenium content of infant formulas is proposed. It includes wet digestion with nitric acid and hydrogen peroxide in medium pressure teflon bombs in a microwave oven and determination by graphite furnace atomic absorption spectrometry (GFAAS). The absence of interferences is checked. Values obtained for the limit of detection (19.4 ng/g), precision (RSD = 2.2%) and accuracy by analysis of a reference material show that the method is reliable.
Determination of inorganic species of Sb and Te in cereals by hydride generation atomic fluorescence spectrometry
2011
A non-chromatographic fast, sensitive and easy method has been developed for the determination of Sb(III), Sb(V), Te(IV) and Te(VI) in cereal samples. The procedure is based on ultrasound assisted extraction and determination by hydride generation atomic fluorescence spectrometry (HG AFS). Preliminary studies were made in order to get the best extraction efficiency using 1 mol L-1 phosphoric acid, 1 mol L-1 nitric acid, aqua regia, 1 mol L-1 sulfuric acid and 6 mol L-1 hydrochloric acid. The extraction with aquaregia showed a clear interconversion of the species during the process, being H2SO4 the best extractant with efficiencies greater than 90% from the total content of Sb and Te quantif…
Non-chromatographic speciation of toxic arsenic in fish
2004
Abstract A rapid, sensitive and economic method has been developed for the direct determination of toxic species of arsenic present in fish and mussel samples. As(III), As(V), dimethylarsinic acid (DMA), and monomethylarsonic acid (MMA) were determined by hydride generation–atomic fluorescence spectrometry using a series of proportional equations without the need of a chromatographic previous separation. The method is based on the extraction of arsenic species from fish through sonication with HNO3 3 mol l−1 and 0.1% (m/v) Triton and washing of the solid phase with 0.1% (m/v) EDTA, followed by direct measurement of the corresponding hydrides in four different experimental conditions. The li…
Direct FIA—AS determination of potassium and magnesium in cement samples by use of the slurries approach
1992
A direct procedure has been developed for the flame atomic determination of potassium and magnesium in cement samples. A 50-mg sample is dispersed in 25 ml of 0.13M nitric acid; 100 mul of this slurry is injected in a double channel FIA manifold simultaneously with 100 mul of a 10% (w/v) lanthanum solution. This procedure allows the rapid extraction of potassium and magnesium by leaching of the sample; nitric acid is not necessary if only potassium must be determined and the sample can be diluted with only distilled water. Aqueous standards are used. The manifold employed includes a well-stirred mixing chamber, which provides an adequate on-line dilution of the sample, in order to obtain em…
Atomic fluorescence determination of inorganic arsenic in soils after microwave-assisted distillation
2000
Abstract An inexpensive microwave-assisted distillation procedure has been developed for quantitative determination of inorganic arsenic in soils by atomic fluorescence spectrometry (AFS). After reduction of As(V) to its trivalent state with potassium iodide, inorganic arsenic was distilled as AsCl 3 that was finally determined by atomic fluorescence after hydride generation with NaBH 4 in HCl medium. The different parameters that control the distillation: concentration and volume of HCl, time of distillation, sample weight, and oven load, were studied. The methodology developed has a detection limit of 0.015 μg l −1 , which corresponds to a concentration of 0.006 μg of As per gram of soil,…
Development and Optimization of Pre-Concentration Procedure of Rare-Earth Elements (REEs) in Their Minerals, Using Microwave - Assisted Sample Dissol…
2015
Abstract The aim of this research was to develop and optimize a procedure for determination of REEs in xenotime and monazite samples collected from Bangka Island, which were compared to Standard Monazite (71 AG) of Bureau of Analyzed Samples, London. ICP-OES method was used for the determination. The samples were dried and sterilized by heating for a week at 110 °C, before digesting with nitric acid and hydrofluoric acid, using a microwave-assisted digestion system. After a careful line selection, at the detection limits for all REEs in the ng/mL the REEs were reliably obtained at the 0.09 – 38% level.
Homogeneous freezing of single sulfuric and nitric acid solution drops levitated in an acoustic trap
2009
Abstract The freezing temperatures of single supercooled drops of binary and ternary sulfuric and nitric acid solutions were measured while varying the acid concentration. An acoustic levitator was used which allows to freely suspend single solution drops in air without electrical charges thereby avoiding any electrical influences which may affect the freezing process. The drops of typically 500 µm in radius were monitored by a video camera during cooling cycles down to − 85 °C to simulate the upper tropospheric and stratospheric temperature range. The present data confirm that liquid solution droplets can be supercooled far below the equilibrium melting point by approximately 35 °C. They f…
Determination of cobalt, copper, iron, nickel and zinc in cemented tungsten carbides with cobalt as a binder by FAAS: Matrix effect control by multiv…
1997
A new approach for the determination of cobalt, copper, iron, nickel and zinc in cemented tungsten carbides with cobalt as a binder by flame atomic absorption spectrophotometry (FAAS) is reported. Real samples were dissolved in phosphoric, hydrochloric and nitric acid. PTFE bomb or alternatively small amounts of HF were used for the enhancement of the recovery of the elements investigated. Synthetic samples were used for interference studies. Multiple linear regression was applied for the control of matrix effects and it proved to be very effective in the search for interfering elements. Using simple acid based standards, all investigated elements could be determined sequentially in a compl…