Search results for "none"

showing 10 items of 1921 documents

Development of a fully automated sequential injection solid-phase extraction procedure coupled to liquid chromatography to determine free 2-hydroxy-4…

2010

Abstract 2-Hydroxy-4-methoxybenzophenone and 2-hydroxy-4-methoxybenzophenone-5-sulphonic acid, commonly known as benzophenone-3 (BZ3) and benzophenone-4 (BZ4), respectively, are substances widely used as UV filters in cosmetic products in order to absorb UV radiation and protect human skin from direct exposure to the deleterious wavelengths of sunlight. As with other UV filters, there is evidence of their percutaneous absorption. This work describes an analytical method developed to determine trace levels of free BZ3 and BZ4 in human urine. The methodology is based on a solid-phase extraction (SPE) procedure for clean-up and pre-concentration, followed by the monitoring of the UV filters by…

Detection limitAnalyteChromatographymedicine.diagnostic_testChemistryElutionSolid Phase ExtractionExtraction (chemistry)TemperatureHydrogen-Ion ConcentrationBiochemistryAnalytical ChemistryBenzophenonesSpectrophotometryStandard additionmedicineHumansEnvironmental ChemistrySpectrophotometry UltravioletSolid phase extractionSelectivitySunscreening AgentsChromatography High Pressure LiquidSpectroscopyAnalytica Chimica Acta
researchProduct

Sequential injection analysis for benzophenone-4 and phenylbenzimidazole sulphonic acid in sunscreen sprays by solid-phase extraction coupled with ul…

2002

Abstract A sequential injection UV method was developed to determine benzophenone-4 (BZ4) and phenylbenzimidazole sulphonic acid (PBS) simultaneously, these being the most commonly used UV-filters in aqueous formulations used as sunscreen sprays. The selective elution of both was performed by on-line solid-phase extraction, by retention on a SAX microcolumn and separation by varying the pH of elution. The sensitivity obtained was 0.042±0.001 ml μg −1 for PBS and 0.0159±0.0003 ml μg −1 for BZ4. The limit of detection was 1.6 μg ml −1 for PBS and 0.6 μg ml −1 for BZ4. The R.S.D. of the results was 1–6% for PBS and 1–12% for BZ4. The method was validated using commercial sunscreen formulations…

Detection limitAqueous solutionChromatographyElutionExtraction (chemistry)Mass spectrometryBiochemistryAnalytical Chemistrychemistry.chemical_compoundchemistryReagentBenzophenoneEnvironmental ChemistrySolid phase extractionSpectroscopyAnalytica Chimica Acta
researchProduct

A tandem-flow assembly for the chemiluminometric determination of hydroquinone

2003

A direct chemiluminescent procedure for determination of hydroquinone based on the emergent flow methodology known as multicommutation or tandem-flow is presented for first time. The manifold was based on a set of three channels and three solenoid valves; and, the determination was performed at 60degreesC and at flow-rate of 7.5 ml min(-1). The complete cycle lasted 35 s, which resulted in a sample flow trough of 103 h(-1). The chemical process was the hydroquinone oxidation with the system sulphuric acid-potassium permanganate; and the light emission was clearly enhanced by the presence of quinine sulphate and benzalkonium chloride reaching a detection limit of 30 Rg l(-1). The dynamic int…

Detection limitChemiluminescenceChromatographyHydroquinoneHydroquinonePermanganateAnalytical chemistrySulfuric acidAnalytical Chemistrylaw.inventionchemistry.chemical_compoundBenzalkonium chloridePotassium permanganatechemistryEnvironmental sampleslawTandem-flowQUIMICA ANALITICAmedicinePharmaceuticalsLight emissionChemiluminescencemedicine.drugTalanta
researchProduct

Sensitive determination of free benzophenone-3 in human urine samples based on an ionic liquid as extractant phase in single-drop microextraction pri…

2007

Abstract Benzophenone-3 (BZ3), one of the compounds most commonly used as UV filter in cosmetic products, can be absorbed through the skin into the human body, since it can be found at trace levels in urine from users of cosmetic products that contain BZ3. Moreover, different undesirable effects have been attributed to this compound. Thus, sensitive analytical methods to monitor urinary excretion of this compound should be developed. This paper presents a selective and sensitive methodology for BZ3 determination at ultratrace levels in human urine samples. The methodology is based on a novel microextraction technique, known as single-drop microextraction (SDME). An ionic liquid (IL) has bee…

Detection limitChromatographyCentral composite designOrganic ChemistryAnalytical chemistryTemperatureIonic LiquidsGeneral MedicineBiochemistryHigh-performance liquid chromatographyChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundBenzophenoneschemistryIonic strengthLiquid–liquid extractionStandard additionIonic liquidHumansSample preparationChromatography LiquidJournal of chromatography. A
researchProduct

Sequential injection spectrophotometric determination of oxybenzone in lipsticks

2001

A sequential injection (SI) procedure for the spectrophotometric determination of oxybenzone in lipsticks is reported. The colorimetric reaction between nickel and oxybenzone was used. SI parameters such as sample solution volume, reagent solution volume, propulsion flow rate and reaction coil length were studied. The limit of detection was 3 microg ml(-1). The sensitivity was 0.0108+/-0.0002 ml microg(-1). The relative standard deviations of the results were between 6 and 12%. The real concentrations of samples and the values obtained by HPLC were comparable. Microwave sample pre-treatment allowed the extraction of oxybenzone with ethanol, thus avoiding the use of toxic organic solvents. E…

Detection limitChromatographyChemistryExtraction (chemistry)CosmeticsBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryVolumetric flow rateBenzophenoneschemistry.chemical_compoundVolume (thermodynamics)SpectrophotometryReagentElectrochemistryEnvironmental ChemistryOxybenzoneQuantitative analysis (chemistry)SpectroscopyThe Analyst
researchProduct

Flow-injection spectrophometric determination of propoxur with p-aminophenol

1992

Abstract The spectrophotomeric determination of propoxur [2-(1-methyxlthoxy)phenyl methyl carbamate] was carried out with p -aminophenol (PAP) in a flow system. The method involves the on-line hydrolysis with NaOH of propoxur to 2-isopropoxyphenol and the oxidation of PAP to its relative quinone imine with KIO 4 and the reaction between the phenolate and the quinone imine. A four-channel flow manifold was employed to carry out all the different steps of the reaction considered, monitoring the indo dye formed at 600 nm. The developed procedure provides a typical calibration line of A = 0.000 7 + 1.8 × 10 3 C ( A = absorbance; C = concentration in M) with a regression coefficient of 0.9998 an…

Detection limitChromatographyP-AminophenolIminePropoxurBiochemistryAnalytical ChemistryMethyl carbamateQuinoneAbsorbanceHydrolysischemistry.chemical_compoundchemistryEnvironmental ChemistrySpectroscopyAnalytica Chimica Acta
researchProduct

Determination of hydroxylated benzophenone UV filters in sea water samples by dispersive liquid-liquid microextraction followed by gas chromatography…

2010

A new analytical method for the determination of four hydroxylated benzophenone UV filters (i.e. 2-hydroxy-4-methoxybenzophenone (HMB), 2,4-dihydroxybenzophenone (DHB), 2,2'-dihydroxy-4-methoxybenzophenone (DHMB) and 2,3,4-trihydroxybenzophenone (THB)) in sea water samples is presented. The method is based on dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC-MS) determination. The variables involved in the DLLME process were studied. Under optimized conditions, 1000 microL of acetone (disperser solvent) containing 60 microL of chloroform (extraction solvent) were injected into 5 mL of aqueous sample adjusted to pH 4 and containing 10% NaCl…

Detection limitChromatographySilylationOrganic ChemistryGeneral MedicineBSTFAChemical FractionationBiochemistryGas Chromatography-Mass SpectrometryAnalytical Chemistrychemistry.chemical_compoundBenzophenoneschemistryStandard additionSample preparationSeawaterGas chromatographyGas chromatography–mass spectrometryDerivatizationWater Pollutants ChemicalJournal of chromatography. A
researchProduct

Amphetamine and methamphetamine determination in urine by reversed-phase high-performance liquid chromatography with sodium 1,2-napthoquinone 4-sulfo…

1995

A rapid method is described for the identification and determination of amphetamine and methamphetamine in human urine samples by liquid chromatography with UV-Vis detection. The samples were transferred onto a C18 solid-phase extraction column and chromatographed on a Hypersil ODS RP C18, 5 microns (250 x 4 mm I.D.) with an acetonitrile-water elution gradient containing propylamine. Under these conditions, the amines are eluted with a short retention time. The procedure has been applied to the determination of amphetamine and methamphetamine in the range 0.3-4.0 micrograms/ml in spiked urine samples. The detection limits at 280 nm were 4 and 2 ng/ml for amphetamine and methamphetamine, res…

Detection limitChromatographySpectrophotometry InfraredElutionChemistryExtraction (chemistry)Reproducibility of ResultsPropylamineGeneral ChemistryMethamphetamineHigh-performance liquid chromatographyMethamphetamineAmphetaminechemistry.chemical_compoundmedicineHumansIndicators and ReagentsSolid phase extractionQuantitative analysis (chemistry)Chromatography High Pressure LiquidNaphthoquinonesmedicine.drugJournal of Chromatography B: Biomedical Sciences and Applications
researchProduct

A rapid HPLC assay for zearalenone in laboratory cultures ofFusarium graminearum

1993

A high pressure liquid chromatographic (HPLC) method to determine zearalenone in corn contaminated withFusarium graminearum is described. After extraction with methanol-water and solvent partition, samples were cleaned up by applying the extract to a disposable silica cartridge and by eluting the toxin with a mixture of hexane/dry ethyl ether (5/5). Separation was achieved by a reverse phase μBondapak C18 column followed by fluorescence detection using an excitation wavelength at 274 nm and an emission wavelength at 440 nm. Detection limit was about 5 ng. Recoveries ranging from 85.37 to 100.97%, in standard solutions range 30–0.5 µg/ml, were found.

Detection limitChromatographyVeterinary (miscellaneous)Extraction (chemistry)EtherStandard solutionApplied Microbiology and BiotechnologyMicrobiologyHigh-performance liquid chromatographySolventHexanechemistry.chemical_compoundchemistryAgronomy and Crop ScienceZearalenoneMycopathologia
researchProduct

Flow analysis-spectrophotometric determination of ?-dopa in pharmaceutical formulations by reaction with p-Aminophenol

1994

Abstract A new method has been developed for the spectrophotometric determination of l -dopa in pharmaceutical formulations. The method is based on the reaction between the open-chain quinone of l -dopa, obtained in NaOH, and the benzoqinoneimine form of p-aminophenol, in the presence of KIO4. The reaction product is determined at 574 nm by using both alternately procedures, one based on the stopped-flow and another on a flow injection approach. Under the best experimental conditions L-dopa can be determined with a limit of detection of 52 ng/ml and a relative standard deviation of 0.2% for three replicate measurements of a solution containing 4 μg/ml.

Detection limitChromatographymedicine.diagnostic_testChemistryP-AminophenolRelative standard deviationDosage formAnalytical ChemistryQuinonechemistry.chemical_compoundSpectrophotometrymedicineDerivatizationQuantitative analysis (chemistry)Talanta
researchProduct