Shell-Structure and Pairing Interaction in Superheavy Nuclei: Rotational Properties of the Z=104 Nucleus (256)Rf
2012
The rotational band structure of the Z ¼ 104 nucleus 256Rf has been observed up to a tentative spin of 20@ using state-of-the-art -ray spectroscopic techniques. This represents the first such measurement in a superheavy nucleus whose stability is entirely derived from the shell-correction energy. The observed rotational properties are compared to those of neighboring nuclei and it is shown that the kinematic and dynamic moments of inertia are sensitive to the underlying single-particle shell structure and the specific location of high-j orbitals. The moments of inertia therefore provide a sensitive test of shell structure and pairing in superheavy nuclei which is essential to ensure the val…
High-precision Penning-trap mass measurements of heavy xenon isotopes for nuclear structure studies
2009
With the double Penning-trap mass spectrometer ISOLTRAP at ISOLDE/CERN the masses of the neutron-rich isotopes $^{136\ensuremath{-}146}\mathrm{Xe}$ were measured with a relative uncertainty of the order of ${10}^{\ensuremath{-}8}$ to ${10}^{\ensuremath{-}7}$. In particular, the masses of $^{144\ensuremath{-}146}\mathrm{Xe}$ were measured for the first time. These new mass values allow one to extend calculations of the mass surface in this region. Proton-Neutron interaction strength, obtained from double differences of binding energies, relate to subtle structural effects, such as the onset of octupole correlations, the growth of collectivity, and its relation to the underlying shell model l…
Heavy-Ion Radiation Impact on a 4 Mb FRAM Under Different Test Modes and Conditions
2016
International audience; The impact of heavy-ions on commercial Ferroelectric Memories (FRAMs) is analyzed. The influence of dynamic and static test modes as well as several stimuli on the error rate of this memory is investigated. Static test results show that the memory is prone to temporary effects occurring in the peripheral circuitry, with a possible effect due to fluence. Dynamic tests results show a high sensitivity of this memory to switching activity of this peripheral circuitry.
Towards high-resolution laser ionization spectroscopy of the heaviest elements in supersonic gas jet expansion
2017
Resonant laser ionization and spectroscopy are widely used techniques at radioactive ion beam facilities to produce pure beams of exotic nuclei and measure the shape, size, spin and electromagnetic multipole moments of these nuclei. However, in such measurements it is difficult to combine a high efficiency with a high spectral resolution. Here we demonstrate the on-line application of atomic laser ionization spectroscopy in a supersonic gas jet, a technique suited for high-precision studies of the ground- and isomeric-state properties of nuclei located at the extremes of stability. The technique is characterized in a measurement on actinium isotopes around the N=126 neutron shell closure. A…
Radium ionization scheme development: The first observed autoionizing states and optical pumping effects in the hot cavity environment
2018
© 2018 The Authors This paper reports on resonance ionization scheme development for the production of exotic radium ion beams with the Resonance Ionization Laser Ion Source (RILIS) of the CERN-ISOLDE radioactive ion beam facility. During the study, autoionizing states of atomic radium were observed for the first time. Three ionization schemes were identified, originating from the 7s2 1S0 atomic ground state. The optimal of the identified ionization schemes involves five atomic transitions, four of which are induced by three resonantly tuned lasers. This is the first hot cavity RILIS ionization scheme to employ optical pumping effects. The details of the spectroscopic studies are described …
Production of ionic and atomic beams of alkaline elements
1980
Abstract An on-line mass spectrometer has been developed and used to perform atomic and nuclear spectroscopy on long series of alkali isotopes including nuclei far from stability. The apparatus was on-line either to the ISOLDE mass separator or directly to the PS, proton beam. In the case of atomic spectroscopy, a thermal atomic beam is needed. As ISOLDE delivers 60 keV ions, a high efficiency “ion-to-atom coverter” has been developed. In all cases, an “ionizer” is required to produce 10 keV ions for the ion source of the mass spectrometer. These two special devices are described, their efficiency and the consequent delay times discussed. The different targets which have been developed for …
Prospects for quarkonium studies at the high-luminosity LHC
2020
Prospects for quarkonium-production studies accessible during the upcoming high-luminosity phases of the CERN Large Hadron Collider operation after 2021 are reviewed. Current experimental and theoretical open issues in the field are assessed together with the potential for future studies in quarkonium-related physics. This will be possible through the exploitation of the huge data samples to be collected in proton-proton, proton-nucleus and nucleus-nucleus collisions, both in the collider and fixed-target modes. Such investigations include, among others, those of: (i) J/psi and Upsilon produced in association with other hard particles; (ii) chi(c,b) and eta(c,b) down to small transverse mom…
Status of HIGISOL a new version equipped with SPIG and electric field guidance
2001
A new HIGISOL chamber devoted to the study of short-lived products from heavy-ion-induced fusion-evaporation reactions is proposed. It enables, via the extraction of ions by means of a SPIG (SextuPole rf Ion Guide), to improve the mass resolving power by a factor 2.5 compared to the previous system using a skimmer-ring assembly. The gas cell was also equiped with an electric field for faster transportation of recoiling ions to the nozzle where they are ejected with the gas jet. The first results obtained both with a radioactive α-source and cyclotron beam will be reported.
Experimental investigations of the hypernucleus $_Λ^4$H
2015
International audience; Negatively charged pions from two-body decays of stopped _Lambda^4H hypernuclei were studied in 2012 at the Mainz Microtron MAMI, Germany. The momenta of the decay-pions were measured with unprecedented precision by using high-resolution magnetic spectrometers. A challenge of the experiment was the tagging of kaons from associated K^+∧ production off a Be target at very forward angles. In the year 2014, this experiment was continued with a better control of the systematic uncertainties, with better suppression of coincident and random background, improved particle identification, and with higher luminosities. Another key point of the progress was the improvemen…
RAPTOR : A new collinear laser ionization spectroscopy and laser-radiofrequency double-resonance experiment at the IGISOL facility
2023
RAPTOR, Resonance ionization spectroscopy And Purification Traps for Optimized spectRoscopy, is a new collinear resonance ionization spectroscopy device constructed at the Ion Guide Isotope Separator On-Line (IGISOL) facility at the University of Jyv\"askyl\"a, Finland. By operating at beam energies of under 10 keV, the footprint of the experiment is reduced compared to more traditional collinear laser spectroscopy beamlines. In addition, RAPTOR is coupled to the JYFLTRAP Penning trap mass spectrometer, opening a window to laser-assisted nuclear-state selective purification, serving not only the mass measurement program, but also supporting post-trap decay spectroscopy experiments. Finally,…