Search results for "nuclear medicine"
showing 10 items of 3573 documents
Microscale X-ray mapping of CZT arrays: Spatial dependence of amplitude, shape and multiplicity of detector pulses
2018
In this work, we present the results of a microscale X-ray mapping of a 2 mm thick CZT pixel detector, with pixel pitches of 500 μm and 250 μm, using collimated synchrotron X-ray sources at the Diamond Light source (U. K.). The detector is dc coupled to a fast and low noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to perform online fast pulse shape and height analysis (PSHA), with low dead time and reasonable energy resolution at both low and high fluxes. The detector allows high bias voltage operation (> 5000 V/cm) and good energy resolution at room temperature (5.3 %, 2.3 % and 2.1 % FWHM at 22.1, 59…
Prevalencia y factores de desgaste profesional en radiólogos durante la pandemia COVID-19
2022
Antecedentes: La epidemia por coronavirus 2019 (COVID-19) se ha extendido por todo el mundo desde principios de 2020, sometiendo a los profesionales sanitarios a una sobrecarga laboral ya un mayor nivel de estrés físico y emocional. Objetivos: El objetivo de este estudio es determinar la prevalencia de desgaste profesional y sus posibles factores asociados en los radiólogos españoles durante la COVID-19, y su comparación con la situación previa a la pandemia. Métodos: Estudio observacional realizado entre los meses de abril y agosto de 2020 (durante la pandemia) mediante una encuesta en línea. Se obtuvieron un total de 150 respuestas. Se recopiló y comparó la información demográfica y labor…
Structured reporting of rectal cancer staging and restaging: A consensus proposal
2021
Background: Structured reporting (SR) in oncologic imaging is becoming necessary and has recently been recognized by major scientific societies. The aim of this study was to build MRI-based structured reports for rectal cancer (RC) staging and restaging in order to provide clinicians all critical tumor information. Materials and Methods: A panel of radiologist experts in abdominal imaging, called the members of the Italian Society of Medical and Interventional Radiology, was established. The modified Delphi process was used to build the SR and to assess the level of agreement in all sections. The Cronbach’s alpha (Cα) correlation coefficient was used to assess the internal consistency of ea…
Ultrasound bioeffects in rats: quantification of cellular damage in the fetal liver after pulsed Doppler imaging
2011
Objective To determine whether pulsed Doppler examination of the ductus venosus in rat fetuses could damage exposed tissue. Methods On gestational day 18, the livers of a mean of approximately five fetuses per mother (n = 5.14, SD = 1.6), in a cohort of 35 pregnant female rats, were exposed individually to pulsed Doppler and these were considered the 'exposed group'. The remaining fetuses in each pregnant rat (n = 5.16, SD = 2.1) formed the 'control group'. We tested for 600, 300, 60, 20, 15, 10 and 3 s of exposure of the fetal ductus venosus and the damage was evaluated measuring a cell death index of apoptotic activity at 7 h post-exposure (n = 16). In addition, subgroups of mothers were …
Intravenous Contrast Material for Cardiac Computed Tomography
2023
Purpose: The Italian Registry of Contrast Material use in Cardiac Computed Tomography (iRCM-CCT) is a multicenter, multivendor, observational study on the use of contrast media (CM) in patients undergoing cardiac computed tomography (CCT). The aim of iRCM-CCT is to assess image quality and safety profile of intravenous CM compounds. Materials and methods: iRCM-CCT enrolled 1842 consecutive patients undergoing CCT (≥50 per site) at 20 cluster sites with the indication of suspected coronary artery disease. Demographic characteristics, CCT, and CM protocols, clinical indications, safety markers, radiation dose reports, qualitative (ie, poor vascular enhancement) and quantitative (ie, HU attenu…
An International Survey of Quality and Safety Programs in Radiology
2021
Purpose: The aim of this study was to determine the status of radiology quality improvement programs in a variety of selected nations worldwide. Methods: A survey was developed by select members of the International Economics Committee of the American College of Radiology on quality programs and was distributed to committee members. Members responded on behalf of their country. The 51-question survey asked about 12 different quality initiatives which were grouped into 4 themes: departments, users, equipment, and outcomes. Respondents reported whether a designated type of quality initiative was used in their country and answered subsequent questions further characterizing it. Results: The re…
Automated Detection of Microaneurysms Using Scale-Adapted Blob Analysis and Semi-Supervised Learning
2014
International audience; Despite several attempts, automated detection of microaneurysm (MA) from digital fundus images still remains to be an open issue. This is due to the subtle nature of MAs against the surrounding tissues. In this paper, the microaneurysm detection problem is modeled as finding interest regions or blobs from an image and an automatic local-scale selection technique is presented. Several scale-adapted region descriptors are then introduced to characterize these blob regions. A semi-supervised based learning approach, which requires few manually annotated learning examples, is also proposed to train a classifier to detect true MAs. The developed system is built using only…
A Shape-based Statistical Method to Retrieve 2D TRUS-MR Slice Correspondence for Prostate Biopsy
2012
International audience; This paper presents a method based on shape-context and statistical measures to match interventional 2D Trans Rectal Ultrasound (TRUS) slice during prostate biopsy to a 2D Magnetic Resonance (MR) slice of a pre-acquired prostate volume. Accurate biopsy tissue sampling requires translation of the MR slice information on the TRUS guided biopsy slice. However, this translation or fusion requires the knowledge of the spatial position of the TRUS slice and this is only possible with the use of an electro-magnetic (EM) tracker attached to the TRUS probe. Since, the use of EM tracker is not common in clinical practice and 3D TRUS is not used during biopsy, we propose to per…
A Multi-Projector Calibration Method for Virtual Reality Simulators with Analytically Defined Screens
2017
The geometric calibration of projectors is a demanding task, particularly for the industry of virtual reality simulators. Different methods have been developed during the last decades to retrieve the intrinsic and extrinsic parameters of projectors, most of them being based on planar homographies and some requiring an extended calibration process. The aim of our research work is to design a fast and user-friendly method to provide multi-projector calibration on analytically defined screens, where a sample is shown for a virtual reality Formula 1 simulator that has a cylindrical screen. The proposed method results from the combination of surveying, photogrammetry and image processing approac…
Shoulder ultrasound: current concepts and future perspectives
2021
Ultrasonography is an established and effective imaging technique that can be used to evaluate articular and periarticular structures around the shoulder. It has been shown to be useful in a wide range of rotator cuff diseases (e.g. tendon tears, rotator cuff calcific tendinopathy and bursitis) as well as non-rotator cuff abnormalities (instability, synovial joint diseases and nerve entrapment syndrome). A scanning protocol is highly recommended to reduce the rate of operators’ errors by following a standardized scheme including a list of main structures. Shoulder ultrasound has several advantages: it is a relatively cheap and widely available technique, free from ionizing radiation, that c…