Search results for "ocular surface"

showing 10 items of 39 documents

Changes in ocular signs and symptoms in patients switching from bimatoprost-timolol to tafluprost-timolol eye drops: an open-label phase IV study.

2019

ObjectivesBimatoprost–timolol (bimatoprost 0.03%–timolol 0.5% fixed-dose combination [FDC]) and tafluprost–timolol (tafluprost 0.0015%–timolol 0.5% FDC) eye drops are currently the only topical intraocular pressure (IOP)-reducing therapies available as preservative-free (PF) prostaglandin and timolol FDC. The aim of this study was to investigate changes to ocular signs and symptoms when patients with ocular hypertension (OH) or open-angle glaucoma (OAG) switched from PF or benzalkonium chloride (BAK)-preserved bimatoprost–timolol to PF tafluprost–timolol eye drops.DesignThis was a 12-week, open-label, phase IV study.SettingSixteen centres in Finland, Germany, Italy and the UK.ParticipantsPa…

MaleIntraocular pressuregenetic structuresOcular hypertensionGlaucomaTimololBenzalkonium chloride0302 clinical medicine1506clinical pharmacology; clinical trials; glaucoma; intraocular pressure; medical ophthalmology; ocular surface; Medicine (all)Aged 80 and overintegumentary systemMedicine (all)General MedicineMiddle AgedIntention to Treat AnalysisDrug Combinations030220 oncology & carcinogenesisTimololFemaleGlaucoma Open-Anglemedicine.drug1718Adultmedicine.medical_specialtyDrug Administration Schedule03 medical and health sciencesOphthalmologymedicineHumansAntihypertensive AgentsIntraocular PressureAgedclinical trialsocular surfaceBimatoprostbusiness.industryResearchPreservatives PharmaceuticalProstaglandins FTafluprostmedicine.diseaseeye diseasesmedical ophthalmologyClinical trialOphthalmologyBimatoprostglaucoma030221 ophthalmology & optometryQuality of LifeOcular Hypertensionsense organsclinical pharmacologyOphthalmic SolutionsbusinessBMJ open
researchProduct

Fitting Scleral Lenses Less Than 15 mm in Diameter: A Review of the Literature.

2020

OBJECTIVE To perform a comprehensive review of the current and historical scientific literature on fitting small scleral lenses (diameter <15 mm) and clarifying their advantages and disadvantages, in addition to their clinical applications. METHODS The literature search was performed through PubMed from MEDLINE. RESULTS Eleven studies of case series (258 eyes) were found. Indications were similar to those of larger scleral lenses, 74% for corneal irregularities (mainly keratoconus), whereas 26% for ocular surface diseases. In the studies on cases of irregular corneas, visual acuity improved significantly regarding the values before and after fitting the lenses (mean, 0.4-0.03 logMar, respec…

MaleKeratoconusmedicine.medical_specialtyVisual acuitygenetic structuresContact LensesProsthesis Designlaw.inventionCorneal Diseases03 medical and health sciences0302 clinical medicineScleral lenslawOphthalmologyProsthesis FittingmedicineHumansbusiness.industryDaily wearmedicine.diseaseeye diseasesLens (optics)Ophthalmology030221 ophthalmology & optometryFemalesense organsmedicine.symptombusinessOcular surface030217 neurology & neurosurgeryScleraEyecontact lens
researchProduct

Correlation between type 2 diabetes, dry eye and Meibomian glands dysfunction

2019

espanolObjetivo Evaluar las glandulas de Meibomio, la superficie ocular y la funcion de la lagrima en pacientes con diabetes tipo 2, y estudiar la correlacion entre estas situaciones. Metodos Estudio prospectivo de 76 varones, 37 de ellos con diabetes tipo 2, con una media de duracion de entre 7±5 anos, y 36 mujeres como grupo control. Tras completar el cuestionario del indice de enfermedad de la superficie ocular (OSDI), se obtuvieron el tiempo de ruptura lagrimal no invasivo (NIBUT) y el patron de la capa lipidica de la lagrima utilizando interferometria y altura del menisco lagrimal/AML. Se estudio la superficie ocular con tincion verde de lisamina y la morfologia de las glandulas con ev…

MaleOriginal articlemedicine.medical_specialtyLightNIBUTDry eyeMeibomian glandType 2 diabetesOptometriaLinea03 medical and health sciences0302 clinical medicineSurveys and QuestionnairesmedicineHumansOcular Surface Disease IndexIn patientProspective StudiesInverse correlationLid marginGynecologyDiabetisbusiness.industryMarx's lineLínea de MarxDiabetesMiddle AgedMeibomian gland dysfunctionMeibomian secretionmedicine.diseaseInterferometrymedicine.anatomical_structureDiabetes Mellitus Type 2TearsOjo seco030221 ophthalmology & optometryDry Eye SyndromesDisfunción de la glándula de Meibomiosense organsbusiness030217 neurology & neurosurgeryOptometryJournal of Optometry
researchProduct

Endophthalmitis after intravitreal injections: incidence, presentation, management, and visual outcome

2015

Purpose To report the incidence and characteristics of endophthalmitis after intravitreal injections of anti–vascular endothelial growth factor agents or corticosteroids and to describe the clinical and bacteriologic characteristics, management, and outcome of these eyes with acute endophthalmitis in France. Design Retrospective, nationwide multicenter case series. Methods From January 2, 2008 to June 30, 2013, a total of 316 576 intravitreal injections from 25 French ophthalmic centers were included. For each center, the number of intravitreal injections was determined using billing codes and the injection protocol was recorded. A registry and hospital records were reviewed to identify pat…

MaleVisual acuityfactor agentsVisual AcuityAngiogenesis InhibitorsEye Infections BacterialEndophthalmitisAntisepticRisk Factorscausative organismsrisk-factorsAged 80 and overEndophthalmitis[SDV.MHEP] Life Sciences [q-bio]/Human health and pathologyIncidence (epidemiology)IncidenceMiddle AgedAnti-Bacterial Agents[SDV.MHEP.OS] Life Sciences [q-bio]/Human health and pathology/Sensory OrgansIntravitreal InjectionsFemaleFrancePresentation (obstetrics)medicine.symptommetaanalysisAdultmedicine.medical_specialtymacular degenerationmedicine.drug_classRetinal DiseasesmedicineHumansranibizumab[SDV.MHEP.OS]Life Sciences [q-bio]/Human health and pathology/Sensory OrgansGlucocorticoidsAgedRetrospective Studiesocular surfaceBacteriabusiness.industryRetrospective cohort studyantibiotic-prophylaxisEye infectionmedicine.diseaseConfidence intervalSurgeryVitreous BodyOphthalmologybusiness[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyoperating-roomendothelial growth-factor
researchProduct

Comparison of the influence of corneo-scleral and scleral lenses on ocular surface and tear film metrics in a presbyopic population

2018

PURPOSE: To assess and compare the effect of the corneo-scleral lenses (C-ScL) and scleral lenses (ScL) on tear film parameters and central corneal thickness (CCT) in healthy presbyopic subjects. METHODS: Thirty subjects wore two contact lenses (CLs), randomly assigned, of neutral power, but of different diameters, 12.7mm (C-ScL) and 18mm (ScL) and being equal in the others parameters: material (HS100) and centre thickness (0.29mm). At baseline, 20min after insertion and at 8h, the tear meniscus area (TMA) and CCT was measured (with optical coherence tomography) as well as tear osmolarity. RESULTS: TMA revealed statistical differences for both lenses at 20min (p<0.001), and also at 8h (p=0.…

Malemedicine.medical_specialtygenetic structuresPopulationNormal valuesCornea03 medical and health sciences0302 clinical medicineScleral lenshemic and lymphatic diseasesCorneaOphthalmologyHumansMedicineProspective Studieseducationeducation.field_of_studybusiness.industryOsmolar ConcentrationfungiBoth lensesEquipment DesignPresbyopiaGeneral MedicinePresbyopiaMiddle AgedContact Lenses Hydrophilicmedicine.diseaseeye diseasesOphthalmologymedicine.anatomical_structureTear meniscusTears030221 ophthalmology & optometryOptometryFemalesense organsbusinessOcular surfaceScleraTomography Optical Coherence030217 neurology & neurosurgeryFollow-Up StudiesOptometryContact Lens and Anterior Eye
researchProduct

Tear &lt;sup&gt;1&lt;/sup&gt;H Nuclear Magnetic Resonance-Based Metabolomics Application to the Molecular Diagnosis of Aqueous Tear Deficiency and Me…

2020

&lt;b&gt;&lt;i&gt;Purpose:&lt;/i&gt;&lt;/b&gt; Meibomian gland dysfunction (MGD) is a major cause of signs and symptoms related to dry eyes (DE) and eyelid inflammation. We investigated the composition of human tears by metabolomic approaches in patients with aqueous tear deficiency and MGD. &lt;b&gt;&lt;i&gt;Methods:&lt;/i&gt;&lt;/b&gt; Participants in this prospective, case-control pilot study were split into patients with aqueous tear deficiency and MGD (DE-MGD [&lt;i&gt;n&lt;/i&gt; = 15]) and healthy controls (CG; &lt;i&gt;n&lt;/i&gt; = 20). Personal interviews, ocular surface disease index (OSDI), and ophthalmic examinations were performed. Reflex tears collected by capillarity were pr…

business.industryDry eyesMeibomian gland dysfunctionAqueous tear deficiencyGeneral Medicinemedicine.diseaseSensory Systems03 medical and health sciencesCellular and Molecular NeuroscienceOphthalmology0302 clinical medicineNuclear magnetic resonanceMetabolomicsmedicine.anatomical_structure030221 ophthalmology & optometrymedicineProton NMRTearsOcular Surface Disease Indexsense organsEyelidbusiness030217 neurology & neurosurgeryOphthalmic Research
researchProduct

Non-invassive assessment of the tear film and the ocular surface: Effect of contact lenses

2022

El diagnóstico y tratamiento del síndrome del ojo seco es un reto debido al carácter multifactorial de la enfermedad y la falta de un test clínico “gold standard”. Además, la falta de correlación entre los signos y síntomas de la enfermedad del ojo seco, la falta de correlación entre métricas, su baja repetibilidad, su carácter invasivo y su relativa objetividad dificulta el estudio de la película lagrimal y el diagnóstico de la enfermedad del ojo seco. En el Capítulo 1 del presente trabajo se describen las características principales de la película lagrimal y la enfermedad del ojo seco, y se realiza una revisión bibliográfica sobre técnicas no invasivas de análisis de la película lagrimal …

dry eyeocular surface:CIENCIAS MÉDICAS ::Ciencias clínicas::Oftalmología [UNESCO]meibomian glands dysfunctionUNESCO::CIENCIAS MÉDICAS ::Ciencias clínicas::Oftalmologíatear filmdry eye disease
researchProduct

The role of dry eye disease in cataract and refractive surgery

2019

El síndrome de ojo seco (DED) puede jugar un papel importante en las cirugías oftálmicas con fines refractivos tanto corneales (tratamiento corneal laser) como cristalinianas (cirugía de catarata) pero también en aquellas cuyo fin es controlar la presión intraocular en pacientes que sufren de glaucoma. El objetivo principal de esta tesis se refiere a la aplicación de una serie de pruebas diagnósticas, de mínimamente a no-invasivas, sugeridas por el Tear Film & Ocular Society Dry Eye WorkShop II (TFOS DEWS II) que pueden ayudar a mejorar los resultandos refractivos y visuales en la cirugía oftálmica actual. La cirugía de cristalino, particularmente la cirugía moderna de catarata y la refract…

dry eyeocular surfacegenetic structuresglaucoma surgery:CIENCIAS MÉDICAS ::Cirugía ::Cirugía ocular [UNESCO]:FÍSICA::Óptica ::Optometría [UNESCO]lens surgerysense organsUNESCO::CIENCIAS MÉDICAS ::Cirugía ::Cirugía oculareye diseasescorneal refractive surgeryUNESCO::FÍSICA::Óptica ::Optometría
researchProduct

Video display terminal use and dry eye: preventive measures and future perspectives

2022

Background: Dry eye disease (DED) is a common cause of ocular pain and discomfort. Dry eye disease (DED) stems from a loss-of-tear film homeostasis and is frequently seen in video display terminal (VDT) users. Video display terminal (VDT) use reduces blink rates and increases incomplete blinks, leading to tear film instability and ocular inflammation, promoting DED. Purpose: To assess and evaluate the methods for preventing VDT-associated DED and ocular discomfort. Methods: Studies were found using PubMed and Embase with the search terms: (digital visual terminal* OR computer use OR screen use OR smartphone OR display OR visual display terminal* OR computer vision syndrome OR tablet OR phon…

genetic structuresCOMPUTER VISION SYNDROMEVDP::Medisinske Fag: 700::Klinisk medisinske fag: 750::Oftalmologi: 754QUALITY-OF-LIFE:Medisinske Fag: 700 [VDP]ergonomic practicesFatty Acids Omega-3tear film stabilityHumansOMEGA-3-FATTY-ACIDS TREATMENTOFFICE WORKERSInflammationMucinsOCULAR SURFACEGeneral Medicinedry eye diseaseeye diseasesvideo display terminalBLINK RATEOphthalmologySPONTANEOUS EYEBLINK ACTIVITYHIGHLY ADJUSTABLE CHAIRComputer TerminalsTearsRISK-FACTORSpreventive measuresDry Eye SyndromesFIELD INTERVENTIONVDP::Matematikk og Naturvitenskap: 400::Informasjons- og kommunikasjonsvitenskap: 420::Simulering visualisering signalbehandling bildeanalyse: 429
researchProduct

Tear Film Surface Quality in Modern Daily Disposable Contact Lens Wear

2021

Objectives As reported previously, tear film surface quality (TFSQ) should be considered in contact lens (CL) fitting. This study followed noninvasive keratograph tear film break-up time (NIKBUT) in CL wearers for 12 months to validate its clinical utility in predicting CL performance. Methods Fifty-five subjects (M/F=17/38) aged 26±4 years were prescribed silicone hydrogel or hydrogel CLs. The study included baseline measurements without CLs; 2 visits for CL fitting and control; follow-up after 3, 6, and 12 months of CL wear; and postwear visit without CLs. Ocular Surface Disease Index (OSDI), 8-Item Contact Lens Dry Eye Questionnaire (CLDEQ-8), first and mean NIKBUT (F/M-NIKBUT), fluoresc…

medicine.medical_specialtyCorneal stainingbusiness.industrySilicone hydrogelContact Lenses HydrophilicEyeContact lensOphthalmologyCLs upper limitsTearsOphthalmologyHumansTearsMedicineDry Eye SyndromesDaily disposableOcular Surface Disease IndexbusinessOcular surfaceVision OcularEye &amp; Contact Lens: Science &amp; Clinical Practice
researchProduct