Search results for "ocular"

showing 10 items of 1219 documents

Spontaneous Resolution of Delayed Suprachoroidal Hemorrhage in the Single Eye Following Needling in Congenital Glaucoma

2017

Suprachoroidal hemorrhage (SCH) is a rare, but potentially vision-threatening event with poor long-term visual prognosis. At present, there is disagreement whether surgical intervention or conservative treatment is superior in the management. We report on a case of spontaneous resolution of severe SCH after needling procedure in the only eye of a young patient with congenital glaucoma.A 43-year-old woman with congenital glaucoma was scheduled for bleb needling in her only eye. Preoperative best-corrected visual acuity was 20/40 and intraocular pressure 20 mm Hg. On the third postoperative day, she developed a massive delayed SCH with appositional (kissing) choroidal bullae and visual acuity…

AdultChoroid Hemorrhagemedicine.medical_specialtyCongenital glaucomagenetic structuresRemission SpontaneousVisual AcuityGlaucomaSuprachoroidal hemorrhagePostoperative Hemorrhage03 medical and health sciences0302 clinical medicineOphthalmologyHumansMedicineIntraocular PressureDry needlingbusiness.industryGlaucomamedicine.diseaseConservative treatmentOphthalmology030221 ophthalmology & optometryDrainageFemalebusinessSclera030217 neurology & neurosurgeryJournal of Glaucoma
researchProduct

Visual performance of the Akreos Adapt AO intraocular lens in patients with different corneal profiles measured with an adaptive optics visual simula…

2012

AIMS: To evaluate the visual performance of an aberration-free intraocular lens (IOL) in patients with different corneal profiles using adaptive optics visual simulation. METHODS: A crx1 adaptive optics visual simulator was used to simulate the aberration pattern of an aberration-free IOL combined with five corneal profiles: virgin corneas and corneas with low and high myopic ablations and low and high hyperopic ablations. Ten eyes of 10 subjects were evaluated, and monocular distance visual acuity (VA) at 100%, 50% and 10% of contrast was measured. RESULTS: At 100% of contrast, no differences were found in VA values among virgin corneas, low and high myopic ablations and low hyperopic abla…

AdultCorneal Wavefront AberrationDistance visual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityIntraocular lensDiagnostic Techniques OphthalmologicalProsthesis DesignContrast SensitivityYoung AdultCellular and Molecular NeuroscienceLens Implantation IntraocularMyopiaHumansContrast (vision)MedicineIn patientAdaptive opticsSimulationmedia_commonLenses IntraocularPhacoemulsificationbusiness.industryAblationeye diseasesSensory SystemsOphthalmologySpherical aberrationHyperopiaOftalmologíaOptometryLasers Excimersense organsbusinessBritish Journal of Ophthalmology
researchProduct

Effect of Simulated IOL Tilt and Decentration on Spherical Aberration After Hyperopic LASIK for Different Intraocular Lenses

2011

PURPOSE: To evaluate visual quality differences among intraocular lenses (IOLs) in patients with previous hyperopic laser ablations and to assess the impact of decentration and tilt of IOLs on visual quality. METHODS: An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of one aberration-correcting IOL (AcrySof IQ SN60WF, Alcon Laboratories Inc) and two spherical IOLs with different amounts of positive spherical aberration (Akreos Adapt [Bausch & Lomb] and Triplato [AJL Ophthalmic]) in five situations—centered, 0.2 mm and 0.4 mm of decentration, and 2° and 4° of tilt—in two groups: simulated low hyperopic laser corneal ablation (low hyperopia group)…

AdultCorneal Wavefront AberrationDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectKeratomileusis Laser In SituVisual AcuityArtificial Lens Implant MigrationRefraction OcularYoung AdultPostoperative ComplicationsHumansMedicineContrast (vision)media_commonLenses Intraocularbusiness.industryLASIKeye diseasesOphthalmologySpherical aberrationHyperopiaTilt (optics)Intraocular lensesDecreased Visual AcuityOftalmologíaOptometryLasers ExcimerSurgerysense organsmedicine.symptombusinessJournal of Refractive Surgery
researchProduct

Visual simulation through an aspheric aberration-correcting intraocular lens in subjects with different corneal profiles using adaptive optics.

2013

The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF® intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF®). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 an…

AdultCorneal Wavefront Aberrationgenetic structuresComputer sciencebusiness.industrymedicine.medical_treatmentVisual AcuityIntraocular lenseye diseasesOphthalmologySpherical aberrationOpticsLens Implantation IntraocularmedicineMyopiaOptometryOftalmologíaHumanssense organsbusinessAdaptive opticsOptometryÓpticaClinicalexperimental optometry
researchProduct

Lentes de contato corneoesclerais adaptadas em córneas irregulares após cirurgia LASIK

2018

ABSTRACT Purpose: We aimed to describe the outcomes of corneoscleral contact lens fitting with multi-aspherical geometry designs in patients with irregular corneas after laser-assisted in situ keratomileusis (LASIK). Methods: This was a retrospective series of 18 patients (age, 26-38 years) selected from an eye clinic database. Participants were required to have unsatisfactory visual acuity with their current contact lenses or spectacles after LASIK for myopia correction. All patients were fitted with corneoscleral contact lenses designed to correct corneal surface irregularities. A diagnostic trial set was used for fitting, and assessments were performed according to a standardized methodo…

AdultCorneal surgery laserIntraocular pressuremedicine.medical_specialtyCorneal Wavefront AberrationVisual acuityPaquimetria corneanagenetic structuresIntraocular pressuremedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityLentes de contatoKeratomileusisCorneal endothelial cell losslaw.invention03 medical and health sciencesCorneal pachymetry0302 clinical medicinePerda de células endoteliais da córneaPressão intraocularlcsh:OphthalmologylawOphthalmologyMyopiaHumansMedicineContact lensesCorneal pachymetryCirurgia da córnea a laserRetrospective Studiesmedicine.diagnostic_testbusiness.industryCorneal TopographyLASIKGeneral MedicineContact Lenses HydrophilicCorneal topographyeye diseasesLens (optics)Contact lensOphthalmologylcsh:RE1-994030221 ophthalmology & optometrysense organsmedicine.symptombusiness030217 neurology & neurosurgeryFollow-Up Studies
researchProduct

Seeing odors in color: Cross-modal associations in children and adults from two cultural environments

2018

International audience; We investigated the occurrence and underlying processes of odor–color associations in French and American 6- to 10-year-old children (n = 386) and adults (n = 137). Nine odorants were chosen according to their familiarity to either cultural group. Participants matched each odor with a color, gave hedonic and familiarity judgments, and identified each odor. By 6 years of age, children displayed culture-specific odor–color associations, but age differences were noted in the type of associations. Children and adults in both cultural groups shared common associations and formed associations that were unique to their environment, underscoring the importance of exposure le…

AdultCross-Cultural ComparisonMalevision[SDV]Life Sciences [q-bio]Ethnic groupColorExperimental and Cognitive PsychologyOlfaction050105 experimental psychologyDevelopmental psychologyJudgment03 medical and health sciences0302 clinical medicineDevelopmental and Educational PsychologyHumans0501 psychology and cognitive sciencesChildAge differences[SDV.NEU.PC]Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]/Psychology and behaviormusculoskeletal neural and ocular physiology05 social sciencesCultural group selectionRecognition Psychologychild (6–10 years)intercultural differencesSmellOdorOdorantsFemalemultisensory developmentodor–color associationsPsychology030217 neurology & neurosurgerypsychological phenomena and processesolfaction
researchProduct

Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration

2011

Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…

AdultDepth of focusCorneal Wavefront AberrationVisual acuityPseudophakiagenetic structuresmedia_common.quotation_subjectVisual AcuityArtificial Lens Implant MigrationCohort StudiesYoung AdultAberrometryPsychophysicsmedicineHumansContrast (vision)Adaptive opticsmedia_commonMathematicsLenses IntraocularDepth PerceptionMonocularAberrometryModels Theoreticalequipment and supplieseye diseasesSensory SystemsOphthalmologySpherical aberrationTilt (optics)OptometrySurgerysense organsmedicine.symptomJournal of Cataract and Refractive Surgery
researchProduct

Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.

2014

Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …

AdultDepth of focusPhakic Intraocular LensesVisual acuityCorneal Wavefront Aberrationgenetic structuresVisual AcuityDiagnostic Techniques OphthalmologicalPhakic intraocular lensProsthesis DesignYoung AdultLens Implantation IntraocularmedicineHumansComputer SimulationAdaptive opticsDioptreMathematicsWavefrontDepth PerceptionPupilPresbyopiaPresbyopiamedicine.diseaseeye diseasesSensory SystemsOphthalmologySpherical aberrationOptometrySurgerysense organsmedicine.symptomJournal of cataract and refractive surgery
researchProduct

Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation

2011

PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…

AdultDepth of focusVisual acuityCorneal Wavefront AberrationPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityCorneaYoung AdultLens Implantation IntraocularCorneaRefractive surgerymedicineHumansDioptreLenses IntraocularDepth Perceptionbusiness.industryAblationRefractive Errorseye diseasesOphthalmologySpherical aberrationmedicine.anatomical_structureOptometryOftalmologíaSurgerysense organsmedicine.symptomDepth perceptionbusiness
researchProduct

Eye Movement Involvement in Parry-Romberg Syndrome: A Clinicopathologic Case Report

2008

We report the case of a 38-year-old woman who developed a progressive bilateral disease in which the eye motility disorder-diplopia-is the outstanding feature over a period of 12 years. The muscle biopsy of the medial rectus muscle did not show any trace of striated muscle. To the best of our knowledge, this is the first pathological report in an affected extraocular muscle of a patient with Parry-Romberg syndrome (PRS). Previous rare reports of diplopia in PRS have been attributed to enophthalmos, progressive atrophy of the orbit, ocular motor nerve dysfunction, or mechanical restrictions.

AdultEye Movementsgenetic structuresExtraocular musclesOcular Motility DisordersOcular Motility DisordersFacial HemiatrophyDiplopiamedicineHumansMuscle biopsymedicine.diagnostic_testbusiness.industryEnophthalmosMedial rectus muscleEye movementParry–Romberg syndromeAnatomymedicine.diseaseFibrosiseye diseasesOphthalmologyOculomotor Musclemedicine.anatomical_structureOculomotor MusclesFemalesense organsmedicine.symptombusinessStrabismus
researchProduct