Search results for "ocular"
showing 10 items of 1219 documents
Short-term Follow-up after Implantation of a Foldable Iris-Fixated Intraocular Lens in Phakic Eyes
2005
Objective To evaluate efficiency, predictability, stability, complications, and patient satisfaction after implantation of a foldable iris-fixated phakic intraocular lens (PIOL) for the correction of myopia. Design Prospective, nonrandomized, comparative (self-controlled) trial. Participants Forty-one eyes of 22 myopic patients aged 18 to 56 years (mean, 36 years) with average sphere of −8.2±2.01 diopters (D; range, −12.25 to −3.75 D) and average preoperative cylinder of −0.90±0.62 D (range, −2.50 to 0.00 D) were enrolled in this prospective study. Methods All eyes underwent implantation of a foldable iris-fixated PIOL with an optical zone of 6.0 mm. The follow-up was 6 months in all cases.…
PREVALENCE AND ASSOCIATIONS OF MYELINATED RETINAL NERVE FIBERS
2016
PURPOSE To determine the prevalence, ocular, and systemic associations of myelinated retinal nerve fibers (MRNF) in a Caucasian cohort. METHODS The Gutenberg Health Study (GHS) is a population-based, prospective cohort study encompassing 15,010 subjects in Germany. Gutenberg Health Study participants, aged 35 to 74 years, stratified for gender, decades of age, and residence were examined for ophthalmologic and systemic conditions. Optic disc centered and macular photographs were reviewed for the presence of MRNF. RESULTS In 25,728 eyes of 12,906 participants (86.0% of the cohort), the prevalence of MRNF was 0.4%. In a binary logistic regression analysis, MRNF was positively associated with …
Tolerability of 24-hour intraocular pressure monitoring of a pressure-sensitive contact lens.
2013
Purpose To investigate tolerability and safety of a new diagnostic device for 24-hour intraocular pressure monitoring in healthy subjects and age-matched glaucoma patients. Patients and methods Twenty healthy subjects (group 1) and 20 age-matched glaucoma patients (group 2) were included in this prospective, single-center, open, observational parallel group study. The SENSIMED Triggerfish Sensor is a soft disposable contact lens embedding a telemetry chip and strain gauge sensor for continuous intraocular pressure monitoring. The Sensor was placed in 1 eye for 24 hours. Tolerability was evaluated using a visual analog scale (range, 0 to 100; 0=no discomfort; 100=very severe discomfort). Saf…
Risk factors of ocular hypertension and glaucoma. The Casteldaccia Eye Study.
1994
A case-control study was planned as a part of the Casteldaccia Eye Study in order to investigate about risk factors of ocular hypertension and glaucoma. Cases were 44 subjects with glaucoma or intraocular pressure of 24 mm Hg or more. Controls were 220 subjects with intraocular pressure of 20 mm Hg or less and no signs of glaucoma. A number of environmental, behavioral, systemic and ocular variables were studied. Among the others we investigated the following: sunlight exposure, smoking, alcohol intake, pregnancies, systemic hypertension, diabetes, use of corticosteroids, refractive status, anterior chamber depth, lens nuclear sclerosis, iris color and texture. After univariate analysis the…
Intraocular pressure after small incision cataract surgery: temporal sclerocorneal versus clear corneal incision.
2001
To compare intraocular pressure (IOP) after phacoemulsification and foldable intraocular lens (IOL) implantation using a temporal sclerocorneal or clear corneal incision.Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany.One hundred patients (100 eyes) with cataract having phacoemulsification with posterior chamber IOL implantation were randomly assigned to receive a temporal sclerocorneal or clear corneal tunnel incision. Intraocular pressure was measured preoperatively and 6 hours, 1, 2, and 3 days, and 5 months postoperatively. Statistical significance was determined by nonparametric group comparisons using 2-sample random Wilcoxon tests.Six hours postoperatively,…
Falsely elevated intraocular pressure due to increased central corneal thickness
1999
PURPOSE: To evaluate whether ocular hypertensive subjects have a higher central corneal thickness than other individuals. METHODS: In this prospective study, 48 subjects with ocular hypertension, 63 patients with open-angle glaucoma, 56 nonglaucomatous patients with diabetes mellitus, and 106 control subjects were evaluated. Corneal thickness was measured by ultrasound pachymetry, and intraocular pressure was determined by Goldmann applanation tonometry. RESULTS: Central corneal thickness was significantly higher in the ocular hypertensive subjects, mean +/- S.D., 592+/-39 microm, than in the patients with glaucoma (536+/-34 microm), the nonglaucomatous patients with diabetes mellitus (550+…
Corneoscleral contact lenses for visual rehabilitation after keratoplasty surgery.
2019
Abstract Purpose To report the use of corneoscleral lenses (CSL) in keratoconus patients who were unsatisfied with their visual outcomes after keratoplasty surgery. Methods Eleven consecutive cases with unsatisfactory vision with spectacles, due to irregular astigmatism, preferred to try CSL before SL due to handling or economic issues. An eye examination included refraction and visual acuity assessment, anterior eye biomicroscopy, ocular fundus examination, corneal topographic analysis, endothelial-cell count (ECC) and evaluation of corneal biomechanical parameters (corneal resistance factor, CRF; corneal hysteresis, CH; corneal-compensated intraocular pressure, IOPcc). The fitting process…
Impact of Corneoscleral Contact Lens Usage on Corneal Biomechanical Parameters in Keratoconic Eyes
2019
Objective To analyze the changes in corneal biomechanical parameters of keratoconic eyes with and without intracorneal ring segment (ICRS) implants after 1 year of corneoscleral contact lens (CScL) wear. Methods Seventy-four eyes of 74 patients were divided into three groups: healthy subjects (29 eyes, control group), and 2 groups of subjects with keratoconic eyes (one group of 20 eyes with ICRS implants and one of 25 eyes without them), which were fitted with CScL. Corneal hysteresis (CH), corneal resistance factor (CRF), and corneal-compensated intraocular pressure (IOPcc) were evaluated before fitting CScL and after 1 year of CScL wear. In addition, endothelial cell count (ECC) and centr…
Intrastromal corneal ring segment implantation in paracentral keratoconus with coincident topographic and coma axis.
2012
To evaluate the efficacy, predictability, and safety of implantation of Ferrara-type intrastromal corneal ring segments (ICRS) for refractive correction of paracentral keratoconus.Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Snellen uncorrected (UDVA) and corrected (CDVA) distance visual acuities and residual refractive errors were recorded before and 6 months after ICRS implantation for keratoconus. The tunnels for ICRS implantation were created with a femtosecond laser. The power vector and the Alpins method were used to analyze postoperative refractive outcomes.The study evaluated 56 eyes of 49 patients. The mean UDVA was 0.17 ± 0.14 (SD) preoperatively and 0.41 …
Where is the locus of the lowercase advantage during sentence reading?
2016
While most models of visual word identification and reading posit that a word's visual codes are rapidly transformed onto case-invariant representations (i.e., table and TABLE would equally activate the word unit corresponding to "table"), a number of experiments have shown a lowercase advantage in various word identification and reading tasks. In the present experiment, we examined the locus of this lowercase advantage by comparing the pattern of eye movements when reading sentences in lowercase vs. uppercase. Each sentence contained a target word that was high or low in word-frequency. Overall, results showed faster reading times for lowercase than for uppercase sentences. More important,…