Search results for "ophthalmologic"
showing 10 items of 49 documents
Recommendations for eye care during the alarm state by the coronavirus disease pandemic COVID-19.
2020
Abstract Objective Minimize exposure to the SARS-CoV-2, reduce the chances of cross-transmission between patients and healthcare personnel, and prevent the development of postoperative complications from the management of patients with eye diseases during the 2019 coronavirus disease pandemic (COVID-19). Methods COVID-19 literature review and consensus establishment between different Spanish ophthalmology societies in order to provide guidelines and recommendations of maximum resources primarily conditioned by the state of alert, confinement and social distancing that occurs in Spain since March 16, 2020. Results The recommendations will promote the adoption of action and protection measure…
Wavefront holoscopy: application of digital in-line holography for the inspection of engraved marks in progressive addition lenses
2014
Progressive addition lenses (PALs) are engraved with permanent marks at standardized locations in order to guarantee correct centering and alignment throughout the manufacturing and mounting processes. Out of the production line, engraved marks provide useful information about the PAL as well as act as locator marks to re-ink again the removable marks. Even though those marks should be visible by simple visual inspection with the naked eye, engraving marks are often faint and weak, obscured by scratches, and partially occluded and difficult to recognize on tinted or antireflection-coated lenses. Here, we present an extremely simple optical device (named as wavefront holoscope) for visualiza…
Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices.
2014
Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured…
Medida da profundidade da câmara anterior, distância branco a branco, ângulo da câmara anterior e diâmetro pupilar usando dois dispositivos de imagen…
2014
Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured…
New method for remote and repeatable monitoring of intraocular pressure variations
2014
We present initial steps toward a new measurement device enabling high-precision, noncontact remote and repeatable monitoring of intraocular pressure (IOP)-based on an innovative measurement principle. Using only a camera and a laser source, the device measures IOP by tracking the secondary speckle pattern trajectories produced by the reflection of an illuminating laser beam from the iris or the sclera. The device was tested on rabbit eyes using two different methods to modify IOP: via an infusion bag and via mechanical pressure. In both cases, the eyes were stimulated with increasing and decreasing ramps of the IOP. As IOP variations changed the speckle distributions reflected back from th…
Endotoxins in ophthalmic viscosurgical devices.
2003
Purpose To measure the endotoxin concentration (EC) of 25 commercially available, hyaluronic acid- and hydroxypropylmethylcellulose-based (HPMC) ophthalmic viscosurgical devices (OVDs). Methods The in vitro Limulus amebocyte lysate (LAL) assay, which indicates the presence of endotoxins originating from gram-negative bacteria, was used to determine the EC. The procedure was performed according to the European Pharmacopoeia/USP. EC including duplicate determinations, negative controls, dilution series with control standard endotoxin, dilution series with sample extract and positive sample control. Results 16 OVDs (Amvisc®, Amvisc® Plus, Biolon®, Coatel®, Healon®, Healon® GV, Healon®5, HPMC O…
A rapid method for measuring intraocular lens power in vitro with a focimeter.
2015
In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation.
Graphic representation of data resulting from measurement comparison trials in cataract and refractive surgery.
2003
* BACKGROUND AND OBJECTIVES: The evaluation of new diagnostic measurement devices allows intraindividual comparison with an established standard method. However, reports in journal articles often omit the adequate incorporation of the intraindividual design into the graphic representation. * PATIENTS AND METHODS: This article illustrates the drawbacks and the possible erroneous conclusions caused by this misleading practice in terms of recent method comparison data resulting from axial length measurement in 220 consecutive patients by both applanation ultrasound and partial coherence interferometry. * RESULTS: Graphic representation of such method comparison data should be based on boxplots…
The Evonik-Mainz-Eye-Care-Study (EMECS): Design and Execution of the Screening Investigation
2014
Purpose To determine if screening for major ophthalmological diseases is feasible within the frame of routine occupational medicine examinations in a large working population. Methods 13037 employees of Evonik Industries aged 40 to 65 years were invited to be screened for major ophthalmological diseases (glaucoma, age related macular degeneration and diabetic retinopathy between June 2007 and March 2008 within an extended setting of occupational medicine. Ophthalmological examinations consisted of visual acuity, objective refraction, pachymetry, tonometry, perimetry (frequency doubling technology), confocal scanning laser ophthalmoscopy and digital fundus photography. Participants responded…
Amyloidosis and Ocular Involvement: an Overview.
2019
Purpose: To describe the ophthalmic manifestations of amyloidosis and the corresponding therapeutic measures.Methods: The 178 patients included in the study had different types of amyloidosis, diagnosed at a single internal medicine institution (Bari, Italy). To provide a comprehensive review of the types of amyloidosis that can be associated with ocular involvement, the images and clinical descriptions of patients with amyloidosis structurally related to gelsolin, keratoepithelin and lactoferrin were obtained in collaborations with the ophthalmology departments of hospitals in Mainz (Germany) and Helsinki (Finland).Results: Overall, ocular morbidity was detected in 41 of the 178 patients w…