Recommendations for eye care during the alarm state by the coronavirus disease pandemic COVID-19.

2020

Abstract Objective Minimize exposure to the SARS-CoV-2, reduce the chances of cross-transmission between patients and healthcare personnel, and prevent the development of postoperative complications from the management of patients with eye diseases during the 2019 coronavirus disease pandemic (COVID-19). Methods COVID-19 literature review and consensus establishment between different Spanish ophthalmology societies in order to provide guidelines and recommendations of maximum resources primarily conditioned by the state of alert, confinement and social distancing that occurs in Spain since March 16, 2020. Results The recommendations will promote the adoption of action and protection measure…

Eye DiseasesAtención oftalmológicaOphthalmologic Surgical ProceduresDiseaseRecommendationsPostoperative Complications0302 clinical medicineRisk FactorsHealth carePandemicOutpatient clinicMedicine030212 general & internal medicineSocieties Medicaleducation.field_of_studySocial distanceChloroquineGeneral MedicineEye careDisease ProgressionOftalmologíaMedical emergencySymptom AssessmentCoronavirus InfectionsAtención oftalmológica COVID-19 Eye care Oftalmología Ophthalmology Pandemia Pandemic Recomendaciones Recommendations SARS-CoV-2HydroxychloroquineInfectious Disease Transmission Patient-to-ProfessionalContact LensesBlood SafetyPneumonia ViralPopulationArticleAntimalarialsBetacoronavirus03 medical and health sciencesHumanseducationPandemicsPersonal protective equipmentPandemiaGovernmentPandemicSARS-CoV-2business.industryCOVID-19medicine.diseaseOphthalmologyWithholding TreatmentSpainAsymptomatic DiseasesRecomendaciones030221 ophthalmology & optometrybusiness
researchProduct

Wavefront holoscopy: application of digital in-line holography for the inspection of engraved marks in progressive addition lenses

2014

Progressive addition lenses (PALs) are engraved with permanent marks at standardized locations in order to guarantee correct centering and alignment throughout the manufacturing and mounting processes. Out of the production line, engraved marks provide useful information about the PAL as well as act as locator marks to re-ink again the removable marks. Even though those marks should be visible by simple visual inspection with the naked eye, engraving marks are often faint and weak, obscured by scratches, and partially occluded and difficult to recognize on tinted or antireflection-coated lenses. Here, we present an extremely simple optical device (named as wavefront holoscope) for visualiza…

In line holographyComputer scienceHolographyNormal DistributionBiomedical EngineeringHolographyDiagnostic Techniques OphthalmologicalEngravinglaw.inventionBiomaterialsAutomationImaging Three-DimensionalOpticslawMaterials TestingImage Processing Computer-AssistedHumansComputer visionLensesProgressive addition lensesWavefrontLaser engravingbusiness.industryLasersReproducibility of ResultsEquipment DesignAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsVisualizationEyeglassesvisual_artCalibrationvisual_art.visual_art_mediumArtificial intelligencebusinessAlgorithmsDigital holographyJournal of Biomedical Optics
researchProduct

Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices.

2014

Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured…

InterferometriaAdultAnterior ChamberScheimpflug principlePhotography/methodsPupil diameterIrisPupila/fisiologiaDiagnostic Techniques OphthalmologicalAnterior chamber anglePupilYoung AdultOpticsAnterior chamber/pathologyImaging Three-Dimensionallcsh:OphthalmologymedicineDiagnostic techniques ophthalmologicalPhotographyHumansPentacam hrDioptrePhysicsWhite to whitemedicine.diagnostic_testbusiness.industryPupilGeneral MedicineTécnicas de diagnóstico oftalmológicoCorneal topographyeye diseasesOphthalmologyInterferometryCâmara anterior/patologialcsh:RE1-994Fotografia/métodosTopografia da córneasense organsCorneal topographyPupil/physiologybusinessNuclear medicineArquivos brasileiros de oftalmologia
researchProduct

Medida da profundidade da câmara anterior, distância branco a branco, ângulo da câmara anterior e diâmetro pupilar usando dois dispositivos de imagen…

2014

Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices. Methods: This transversal study included 80 right eyes from 80 subjects aged from 20 to 40 years. Their spherical equivalents ranged from -4.25 to +1.00 diopters (D). Each eye's anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, were measured for far vision using both the Galilei G4 (double Scheimpflug camera) and the Pentacam HR (single Scheimpflug camera) systems. Results: Mean anterior chamber depths were calculated as 3.12 ± 0.23 mm and 3.19 ± 0.24 mm when measured…

InterferometriaAnterior chamber/pathologyInterferometryCâmara anterior/patologiaPhotography/methodsFotografia/métodosDiagnostic techniques ophthalmologicalTopografia da córneaCorneal topographyPupil/physiologyPupila/fisiologiaTécnicas de diagnóstico oftalmológico
researchProduct

New method for remote and repeatable monitoring of intraocular pressure variations

2014

We present initial steps toward a new measurement device enabling high-precision, noncontact remote and repeatable monitoring of intraocular pressure (IOP)-based on an innovative measurement principle. Using only a camera and a laser source, the device measures IOP by tracking the secondary speckle pattern trajectories produced by the reflection of an illuminating laser beam from the iris or the sclera. The device was tested on rabbit eyes using two different methods to modify IOP: via an infusion bag and via mechanical pressure. In both cases, the eyes were stimulated with increasing and decreasing ramps of the IOP. As IOP variations changed the speckle distributions reflected back from th…

Intraocular pressuregenetic structuresComputer scienceLaser sourceBiomedical EngineeringDiagnostic Techniques Ophthalmologicallaw.inventionBiomaterialsSpeckle patternOpticslawmedicineCalibrationAnimalsIntraocular PressureMonitoring Physiologicbusiness.industryReproducibility of ResultsLasereye diseasesAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic MaterialsScleramedicine.anatomical_structureMeasuring principleRemote Sensing TechnologyRabbitssense organsbusinessSensitivity (electronics)Journal of Biomedical Optics
researchProduct

Endotoxins in ophthalmic viscosurgical devices.

2003

Purpose To measure the endotoxin concentration (EC) of 25 commercially available, hyaluronic acid- and hydroxypropylmethylcellulose-based (HPMC) ophthalmic viscosurgical devices (OVDs). Methods The in vitro Limulus amebocyte lysate (LAL) assay, which indicates the presence of endotoxins originating from gram-negative bacteria, was used to determine the EC. The procedure was performed according to the European Pharmacopoeia/USP. EC including duplicate determinations, negative controls, dilution series with control standard endotoxin, dilution series with sample extract and positive sample control. Results 16 OVDs (Amvisc®, Amvisc® Plus, Biolon®, Coatel®, Healon®, Healon® GV, Healon®5, HPMC O…

LactoseLimulus testOphthalmologic Surgical ProceduresMethylcelluloseSensitivity and Specificity03 medical and health sciences0302 clinical medicineGram-Negative BacteriaOxazinesHumansConcentration factorHyaluronic AcidLimulus TestEndophthalmitisChromatographyPositive sampleChemistryReproducibility of ResultsGeneral MedicineDilutionEndotoxinsOphthalmologyLimulus amebocyte lysateImmunology030221 ophthalmology & optometry030217 neurology & neurosurgery
researchProduct

A rapid method for measuring intraocular lens power in vitro with a focimeter.

2015

In this paper we describe a new method for measuring the intraocular lens (IOL) power using a focimeter, a negative ophthalmic lens and a saline solution (0.9% NaCl). To test this we measured the power of 58 different IOLs and we compared them with the power stated by the manufacturer. Despite the limitations, the results show a good correlation.

Lenses Intraocularmedicine.medical_specialtyOptics and PhotonicsMaterials sciencegenetic structuresmedicine.medical_treatmentReproducibility of ResultsIntraocular lensDiagnostic Techniques Ophthalmologicaleye diseasesSensory Systemslaw.inventionLens (optics)Cellular and Molecular NeuroscienceOphthalmologylawIntraocular lens powerOphthalmologymedicinesense organsExperimental eye research
researchProduct

Graphic representation of data resulting from measurement comparison trials in cataract and refractive surgery.

2003

* BACKGROUND AND OBJECTIVES: The evaluation of new diagnostic measurement devices allows intraindividual comparison with an established standard method. However, reports in journal articles often omit the adequate incorporation of the intraindividual design into the graphic representation. * PATIENTS AND METHODS: This article illustrates the drawbacks and the possible erroneous conclusions caused by this misleading practice in terms of recent method comparison data resulting from axial length measurement in 220 consecutive patients by both applanation ultrasound and partial coherence interferometry. * RESULTS: Graphic representation of such method comparison data should be based on boxplots…

LightConcordancemedicine.medical_treatmentCataract ExtractionDiagnostic Techniques Ophthalmologicalcomputer.software_genreEyeCataractOpticsRefractive surgeryComputer GraphicsMedicineHumansIntraindividual comparisonProspective StudiesGraphicsRepresentation (mathematics)Mathematical ComputingUltrasonographybusiness.industryAxial lengthRefractive ErrorsRefractive Surgical ProceduresOphthalmologyInterferometryMethod comparisonPartial coherence interferometryData Interpretation StatisticalArtificial intelligencebusinesscomputerNatural language processingOphthalmic surgery, lasersimaging : the official journal of the International Society for Imaging in the Eye
researchProduct

The Evonik-Mainz-Eye-Care-Study (EMECS): Design and Execution of the Screening Investigation

2014

Purpose To determine if screening for major ophthalmological diseases is feasible within the frame of routine occupational medicine examinations in a large working population. Methods 13037 employees of Evonik Industries aged 40 to 65 years were invited to be screened for major ophthalmological diseases (glaucoma, age related macular degeneration and diabetic retinopathy between June 2007 and March 2008 within an extended setting of occupational medicine. Ophthalmological examinations consisted of visual acuity, objective refraction, pachymetry, tonometry, perimetry (frequency doubling technology), confocal scanning laser ophthalmoscopy and digital fundus photography. Participants responded…

MaleHealth ScreeningVisual acuityEye DiseasesCross-sectional studyOccupational Health Serviceslcsh:MedicineGlaucomaDiagnostic Techniques OphthalmologicalGermanyMedicine and Health SciencesMass ScreeningPublic and Occupational HealthPublic Health Surveillancelcsh:ScienceMultidisciplinarymedicine.diagnostic_testDiabetic retinopathyMiddle AgedSocioeconomic Aspects of HealthRetinal DisordersFemalemedicine.symptomResearch ArticleAdultmedicine.medical_specialtyOccupational medicineAge DistributionSex FactorsmedicineHumansMass screeningAgedHealth Care Policybusiness.industrylcsh:RFundus photographyGlaucomaOccupational and Industrial Medicinemedicine.diseaseHealth CareOphthalmologyCross-Sectional StudiesSocial history (medicine)Macular DisordersOptometrylcsh:QPreventive MedicinebusinessScreening GuidelinesPLoS ONE
researchProduct

Amyloidosis and Ocular Involvement: an Overview.

2019

Purpose: To describe the ophthalmic manifestations of amyloidosis and the corresponding therapeutic measures.Methods: The 178 patients included in the study had different types of amyloidosis, diagnosed at a single internal medicine institution (Bari, Italy). To provide a comprehensive review of the types of amyloidosis that can be associated with ocular involvement, the images and clinical descriptions of patients with amyloidosis structurally related to gelsolin, keratoepithelin and lactoferrin were obtained in collaborations with the ophthalmology departments of hospitals in Mainz (Germany) and Helsinki (Finland).Results: Overall, ocular morbidity was detected in 41 of the 178 patients w…

MalePathologymedicine.medical_specialtygenetic structuresEye Diseasesmedicine.medical_treatmentCorneal dystrophyDiagnostic Techniques OphthalmologicalEye03 medical and health sciences0302 clinical medicineAA amyloidosismedicineAL amyloidosisHumansCorneal transplantationCorneal epitheliumRetrospective Studiesbiologybusiness.industryAmyloidosisGeneral MedicineAmyloidosisMiddle Agedmedicine.diseaseeye diseases3. Good healthOphthalmologyTransthyretinmedicine.anatomical_structure030221 ophthalmology & optometrybiology.proteinLattice corneal dystrophyFemalesense organsbusiness030217 neurology & neurosurgeryFollow-Up StudiesSeminars in ophthalmology