Search results for "optic disc"
showing 10 items of 36 documents
Uveal effusion syndrome complicated by anterior ischemic optic neuropathy
1995
We report on a case of idiopathic uveal effusion syndrome complicated by AION. To our knowledge such an association hasn't been previously described. We suggest that scleral thickening caused obstruction of vortex veins followed by uveal effusion and compression of posterior ciliary arteries within their intrascleral tract, leading to AION. Nevertheless it can't be excluded that AION was the result of mechanical compression on ciliary vessels of optic disc by choroidal detachment. © 1996, Kluwer Academic Publishers. All rights reserved.
Agreement among 3 optical imaging methods for the assessment of optic disc topography.
2005
Purpose To assess the agreement of disc topography measurements between the Heidelberg Retina Tomograph (HRT II), Retinal Thickness Analyzer (RTA), and Optical Coherence Tomograph (StratusOCT). Design Observational cross-sectional study. Participants Forty-two randomly chosen eyes of 42 subjects. Methods Each subject underwent HRT II, RTA, and StratusOCT examination. Two experienced examiners drew the contour lines for the HRT II and RTA. Bland and Altman plots were used to evaluate agreement for each topographic parameter among the instruments. The Spearman coefficient of rank correlation was evaluated for each topographic parameter. Main Outcome Measures Agreement in the measurement of op…
Optic pit syndrome
1986
In a study of 15 eyes with optic pits fluorescein angiography revealed that only pits associated with serous detachment of the macular retina showed fluorescence in the late venous phase, while the pits uncomplicated by detachment remained hypofluorescent throughout the test. This finding strongly supports the hypothesis that the subretinal fluid producing the macular detachment originates from leakage of vessels located in the floor of the pit. In addition a high incidence of anomalies was found to be associated with optic pits. Therefore the author suggests to call the association between optic pit and large optic disc, parapapillary chorioretinal changes, cilioretinal vessels, situs inve…
Is spectral domain optical coherence tomography useful in improving the contour line with the heidelberg retina tomograph?
2012
Purpose: To compare the measurements of the optic disc in glaucoma patients and glaucoma suspects with spectral domain optical coherence tomography (SD-OCT) and confocal scanning laser ophthalmoscopy (HRT) before and after adjustment of the contour line with the help of the OCT.Methods: In 109 consecutive patients (109 eyes), optic disc parameters were compared prospectively between the 2 devices before and after adjustment of the optic disc area (ODA) on the HRT3 with ODA obtained with the Cirrus SD-OCT as a reference. Intraclass correlation coefficients (ICC) and the 95% limits of agreement (LoA) with Bland-Altman plots were used to compare the agreement of the pre and post-adjustment mea…
2021
AIM: To investigate short- and long-term intraocular pressure (IOP) fluctuations and further ocular and demographic parameters as predictors for normal tension glaucoma (NTG) progression. METHODS: This retrospective, longitudinal cohort study included 137 eyes of 75 patients with NTG, defined by glaucomatous optic disc or visual field defect with normal IOP (<21 mm Hg), independently from therapy regimen. IOP fluctuation, mean, and maximum were inspected with a mean follow-up of 38mo [standard deviation (SD) 18mo]. Inclusion criteria were the performance of minimum two 48-hour profiles including perimetry, Heidelberg retina tomograph (HRT) imaging, and optic disc photographs. The impact …
The Heidelberg retina tomograph ancillary study to the European glaucoma prevention study: study design and baseline factors.
2013
Purpose: To describe the study design and baseline factors of the Heidelberg Retina Tomograph ancillary study within the EGPS. Furthermore, to examine the relationship between HRT optic disc topographic measurements and baseline demographic and ocular factors. Methods: Four hundred and eighty-nine ocular hypertensive participants were included. Each participant completed HRT imaging at least annually. The associations between HRT measurements and IOP, central corneal thickness (CCT), baseline photographic estimates of vertical CDR ratio (CDR), asymmetry between the two eyes in CDR ratio and baseline visual field indices were assessed using regression analysis. Results: Associations between …
Kinetic and static perimetry after 16 years and additional OCT-A analysis in eyes with long-lasting optic disc drusen
2021
The aim of the study is to evaluate the progression of visual field (VF) defects over 16 years of observation and to assess abnormalities in vessels and retinal nerve fibre layer (RNFL) thickness in patients with optic disc drusen (ODD). Both static automated perimetry (SAP) and semi-automated kinetic perimetry (SKP) were performed in 16 eyes of 8 patients (mean age 54 years) with ODD among 26 eyes of 13 patients examined 16 years before. The area of I2e, I4e, III4e, and V4e isopters was measured in deg2. The MD and PSD parameters were estimated using SAP. Optical coherence tomography angiography (OCT-A) was additionally performed in 16 ODD eyes and 16 eyes of 8 healthy subjects to estimate…
Corneal Biomechanics, Retinal Nerve Fiber Layer, and Optic Disc in Children
2014
Purpose. To evaluate the possible associations between corneal biomechanical parameters, optic disc morphology, and retinal nerve fiber layer (RNFL) thickness in healthy white Spanish children. Methods. This cross-sectional study included 100 myopic children and 99 emmetropic children as a control group, ranging in age from 6 to 17 years. The Ocular Response Analyzer was used to measure corneal hysteresis (CH) and corneal resistance factor. The optic disc morphology and RNFL thickness were assessed using posterior segment optical coherence tomography (Cirrus HD-OCT). The axial length was measured using an IOLMaster, whereas the central corneal thickness was measured by anterior segment opti…
Subretinal neovascularization in anterior ischemic optic neuropathy.
1991
A 66-year-old man with typical anterior ischemic optic neuropathy in one eye suffered from edema of the optic disc without functional changes in the fellow eye. However, 7 months later, a reduction in visual acuity, a change in the visual field and a worsening of the contrast-sensitivity curve demonstrated the development of typical anterior ischemic optic neuropathy in this eye as well. After another 6-month period, in addition to these changes, an extensive subretinal neovascular membrane developed in the papillomacular area, which further reduced the patient's visual acuity and required treatment with laser photocoagulation. To our knowledge, this is the first case report of the occurren…
VAMPIRE: Vessel assessment and measurement platform for images of the REtina
2011
We present VAMPIRE, a software application for efficient, semi-automatic quantification of retinal vessel properties with large collections of fundus camera images. VAMPIRE is also an international collaborative project of four image processing groups and five clinical centres. The system provides automatic detection of retinal landmarks (optic disc, vasculature), and quantifies key parameters used frequently in investigative studies: vessel width, vessel branching coefficients, and tortuosity. The ultimate vision is to make VAMPIRE available as a public tool, to support quantification and analysis of large collections of fundus camera images.