Stereo Matching Tecniques for Cloud-top Height Retrieval

2006

This paper presents an ongoing study for the estimation of the cloud-top height by using only geometrical methods. It is based on the hypothesis that an infra-red camera is on board a satellite and pairs of images concern nearly the same scene. Stereo-vision techniques are therefore explored in order to test the methodology for height retrieval and in particular results of several techniques of stereo matching are evaluated. This study includes area-based matching algorithms by implementing the basic versions, without considering any further steps of optimisation to improve the results. Dense depth maps are the final outputs whose reliability is verified by computing error statistics with r…

Matching (statistics)Ground truthPixelCloud-top height multi view stereo matching algorithms satellite infra red images optical flowSettore INF/01 - Informaticabusiness.industryComputer scienceCloud topComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONImage processingData setSet (abstract data type)Computer visionArtificial intelligencebusiness
researchProduct

Methods cooperation for multiresolution motion estimation

2002

For a medical application, we are interested in an estimation of optical flow on a patient's face, particularly around the eyes. Among the methods of optical flow estimation, gradient estimation and block matching are the main methods. However, the gradient-based approach can only be applied for small displacements (one or two pixels). Gener- ally, the process of block matching leads to good results only if the searching strategy is judiciously selected. Our approach is based on a Markov random field model, combined with an algorithm of block match- ing in a multiresolution scheme. The multiresolution approach allows de- tection of a large range of speeds. The large displacements are detect…

Mathematical optimizationRandom fieldMarkov random fieldMarkov chainComputer scienceGeneral EngineeringOptical flowInitializationMotion detectionImage processingAtomic and Molecular Physics and OpticsOptical flow estimationMotion estimationImage resolutionAlgorithmBlock (data storage)Block-matching algorithmOptical Engineering
researchProduct

Using Fourier local magnitude in adaptive smoothness constraints in motion estimation

2007

Like many problems in image analysis, motion estimation is an ill-posed one, since the available data do not always sufficiently constrain the solution. It is therefore necessary to regularize the solution by imposing a smoothness constraint. One of the main difficulties while estimating motion is to preserve the discontinuities of the motion field. In this paper, we address this problem by integrating the motion magnitude information obtained by the Fourier analysis into the smoothness constraint, resulting in an adaptive smoothness. We describe how to achieve this with two different motion estimation approaches: the Horn and Schunck method and the Markov Random Field (MRF) modeling. The t…

Mathematical optimizationRandom fieldMarkov random fieldSmoothness (probability theory)ComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONOptical flowConstraint (information theory)symbols.namesakeMotion fieldArtificial IntelligenceFourier analysisMotion estimationSignal ProcessingsymbolsComputer Vision and Pattern RecognitionAlgorithmSoftwareComputingMethodologies_COMPUTERGRAPHICSMathematicsPattern Recognition Letters
researchProduct

Optical Flow with Theoretically Justified Warping Applied to Medical Imaging

2015

International audience; Motion induced artifacts represent a major obstacle in the correct malignant lesion detection in medical imaging especially in MRI. The goal of this paper is to evaluate the performance of a new non-rigid motion correction algorithm based on the optical flow method. The proposed algorithm specifically addresses three major problems in MRI: the induced gaps in 3D images, the constancy assumption of current optical flow algorithms and the existence of large non-linear movement. In this paper, we compare the performance of extracted kinetic features from the tumor regions under consideration of several 2-D or 3-D motion compensation parameters for the differential diagn…

Medical ImagingMotion CompensationOptical Flow[ SPI.SIGNAL ] Engineering Sciences [physics]/Signal and Image processing[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processing[SPI.SIGNAL] Engineering Sciences [physics]/Signal and Image processingMRI
researchProduct

Contribution to a marker-free system for human motion analysis

2002

This paper presents a novel approach to human gait analysis using a marker-free system. The devised acquisition system is composed of three synchronized and calibrated charge coupled device cameras. The aim of this work is to recognize in gray level image sequences the leg of a walking human and to reconstruct it in the three-dimensional space. An articulated threedimensional (3D) model of the human body, based on the use of tapered superquadric curves, is first introduced. A motion-based segmentation, using morphological operators, is then applied to the image sequences in order to extract the boundaries of the leg in motion. A reconstruction process, based on the use of a least median of …

Motion analysisComputer sciencebusiness.industryOptical flowImage segmentationAtomic and Molecular Physics and OpticsComputer Science ApplicationsGait (human)Motion fieldGait analysisMotion estimationComputer visionSegmentationArtificial intelligenceElectrical and Electronic EngineeringbusinessJournal of Electronic Imaging
researchProduct

A 3-D marker-free system for the analysis of movement disabilities--an application to the legs.

2001

The aim of this paper is to describe an approach allowing the analysis of human motion in three-dimensional (3-D) space. The system that we developed is composed of three charge-coupled-device cameras that capture synchronized image sequences of a human body in motion without the use of markers. Characteristic points belonging to the boundaries of the body in motion are first extracted from the initial images. Two-dimensional superquadrics are then adjusted on these points by a fuzzy clustering process. After that, the position of a 3-D model based on a set of articulated superquadrics, each of them describing a part of the human body, is reconstructed. An optical flow process allows the pr…

Motion analysisLegFuzzy clusteringFuzzy classificationComputer sciencebusiness.industryMovementOptical flowGeneral MedicineGaitMotion (physics)Computer Science ApplicationsGait (human)Motion fieldFuzzy LogicGait analysisSuperquadricsHumansComputer visionDisabled PersonsArtificial intelligenceElectrical and Electronic EngineeringbusinessBiotechnologyIEEE transactions on information technology in biomedicine : a publication of the IEEE Engineering in Medicine and Biology Society
researchProduct

Quantitative study of cardiac wall motion from cine-MRI using frequency-based optical flow methods

2010

The aim of this thesis is to study parietal desynchronisation of the left ventricle from conventional cine-MRI. The first part of our work consisted in the quantification of the left ventricle wall motion of the heart directly from conventional retrospective SSFP type cine-MRI sequences used in the study of cardiac function. The developed methods for measuring displacements within the images are frequency-based optical flow methods. These techniques seem to be particularly adapted to MRI specificities. We have demonstrated their robustness in the event of Rician noise and pixel intensity variations as a function of time. These variations are often associated with the through-plane motion of…

Multicoil MRI[SDV.MHEP] Life Sciences [q-bio]/Human health and pathologyIRM multicanauxOptical flowAsynchronismeHeartLeft ventricleMotion estimationFlux optique multicanauxCiné-IRMEstimation de mouvementsVitesse pariétaleFlux optiqueMulticoil optical flow[ SDV.MHEP ] Life Sciences [q-bio]/Human health and pathologyCine-MRIAsynchronismParietal velocityVentricule gauche[SDV.MHEP]Life Sciences [q-bio]/Human health and pathologyCoeur
researchProduct

An Integrated Neural and Algorithmic System for Optical Flow Computation

1997

Motion detection plays a central role in several visual environments: knowledge of object velocities and trajectories is fundamental in scene interpretation and segmentation. This task appears a simple problem, but detecting moving objects is very difficult, in fact this is a problem that cannot be considered completely solved today [1] [2] [3].

Optical flow computationbusiness.industryComputer scienceEpipolar geometryEpipolar lineOptical flowMotion detectionSegmentationComputer visionArtificial intelligenceFundamental matrix (computer vision)business
researchProduct

Selective Change-Driven Image Processing: A Speeding-Up Strategy

2009

Biologically inspired schemes are a source for the improvement of visual systems. Real-time implementation of image processing algorithms is constrained by the large amount of data to be processed. Full image processing is many times unnecessary since there are many pixels that suffer a small change or not suffer any change at all. A strategy based on delivering and processing pixels, instead of processing the complete frame, is presented. The pixels that have suffered higher changes in each frame, ordered by the absolute value of its change, are read-out and processed. Two examples are shown: a morphological motion detection algorithm and the Horn and Schunck optical flow algorithm. Result…

Pixelbusiness.industryComputer scienceFrame (networking)Digital image processingComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONOptical flowMotion detectionComputer visionImage processingAbsolute valueArtificial intelligencebusiness
researchProduct

Comparison of stereo vision techniques for cloud-top height retrieval

2007

This paper presents an ongoing study for the estimation of the cloud-top height by using only geometrical methods. In agreement with some recent studies showing that it is possible to achieve reliable height estimations not only with the classical methods based on radiative transfer, this article includes a comparison of performances of a selected set of vision algorithms devoted to extract dense disparity maps or motion fields from Infra Red stereo image pairs. This collection includes both area-based techniques and an optical flow-based method and the comparison is accomplished by using a set of cloudy scenes selected from the Along-Track Scanning Radiometer (ATSR2) database. The first gr…

RadiometerSettore INF/01 - Informaticabusiness.industryCloud topComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONOptical flowSet (abstract data type)GeographyStereopsisRadiative transferCloud-top height multi view stereo matching algorithms satellite infra red images optical flow.Computer visionArtificial intelligencebusinessVision algorithmsComputer stereo visionRemote sensing
researchProduct