Search results for "ortography"
showing 10 items of 47 documents
Chimney and periscope grafts observed over 2 years after their use to revascularize 169 renovisceral branches in 77 patients with complex aortic aneu…
2013
^ ^Purpose: To evaluate the performance of periscope and/or chimney grafts (CPGs) in theendovascular treatment of pararenal or thoracoabdominal aneurysms using off-the-shelfdevices.Methods: Between February 2002 and August 2012, 77 consecutive patients (62 men; meanage 7369 years) suffering from pararenal aortic (n¼55), thoracoabdominal (n¼16), or arch tovisceral artery aneurysms (n¼6) were treated with aortic stent-graft implantation requiringchimney and/or periscope grafts to maintain side branch perfusion. CPGs were planned inadvance and were not used as bailout. A standardized follow-up protocol includingcomputed tomographic angiography, laboratory testing, and clinical examination wasp…
Adjunct Perfusion Branch for Reduction of Spinal Cord Ischemia in the Endovascular Repair of Thoracoabdominal Aortic Aneurysms
2017
Background To analyze utilization of a perfusion branch for temporary sac perfusion to reduce the spinal cord ischemia (SCI) in the endovascular repair of thoracoabdominal aortic aneurysms (TAAAs). Methods Between January 2012 and August 2016, 30 patients (18, men; median age 72 years) were treated for TAAAs with total endovascular repair using customized branched/fenestrated endografts in our institution. The median aneurysm size was 6.6 cm. Types of TAAA were: type I, 9 (30%), type II, 5 (16.6%), type III, 4 (13.3%), type IV, 6 (20%), and type V, 6 (20%). Ten patients received a perfusion branch to create an intentional endoleak, which was occluded with vascular plugs in mean interval ti…
Supracoronary ascending aortic replacement in patients with acute aortic dissection type A: What happens to the aortic root in the long run?
2013
ObjectiveOur objective was to determine long-term outcome predictors for patients with acute aortic dissection type A (AADA) and aortic root involvement.MethodsFrom 2001 through 2009, 119 of 152 patients operated on for AADA at a tertiary medical center underwent supracoronary ascending aortic replacement (52 women; mean age, 61 ± 15 years). Those with at least 1-year follow-up (n = 97) were retrospectively assessed for preoperative aortic root disease. Follow-up data were assessed for evidence of new-onset aortic root disease by computed tomography and echocardiography, and for reoperation for aortic root disease.ResultsMedian follow-up was 33.8 months (range, 0-112 months). Twenty-six (27…
Use and durability of femoral vein for autologous reconstruction with infection of the aortoiliofemoral axis.
2014
Objective To analyze early and late mortality, venous morbidity, reinfection, and freedom from reintervention after using the femoral vein (FV) for vascular reconstruction with infection of the aortoiliofemoral axis. Methods By reviewing our database, 86 patients could be identified with implantation of FV grafts in infected fields between November 1995 and July 2012. The patient records were retrospectively analyzed and follow-up information obtained from patients or their general physician. Seventy-one patients presented with prosthetic graft infection and 15 with an infected aneurysm. For data analysis, patients were divided into an aortoiliac (n = 67) and a femoral group (n = 19). Study…
Endovascular Aneurysm Sealing (EVAS) and Chimney EVAS in the Treatment of Failed Endovascular Aneurysm Repairs
2016
Purpose: To assess the technical success and clinical outcome of reinterventions using the Nellix Endovascular Aneurysm Sealing (EVAS) System to treat complications after endovascular aneurysm repair (EVAR). Methods: Fifteen consecutive patients (mean age 79 years; 14 men) with prior EVAR were treated with EVAS between March 2014 and December 2015 at 2 institutions. The failed prior EVARs included 13 bifurcated endografts, 1 bifurcated graft plus fenestrated cuff, and 1 tube endograft. Endoleaks were the predominant indications: type Ia in 10 and type III in 5 (3 type IIIa and 2 type IIIb). All patients presented with progressive aortic aneurysms (median 7.85-cm diameter; range 6.5–11). Ei…
Transgraft sac Embolization Combined with Graft Reinforcement for Refractory Mixed-Type Endoleak.
2018
International audience; An 80-year-old female underwent EVAR 4 years ago. She presented type II endoleak with sac expansion from 68 to 80 mm during 3-year follow-up after EVAR. Although she underwent translumbar percutaneous sac embolization, the AAA sac continued to enlarge, suggesting mixed-type endoleak including type I, II, and III. Transgraft direct sac angiography revealed endoleak cavity without demonstrable feeding vessel. Transgraft sac embolization using n-butyl cyanoacrylate and graft reinforcement was performed concurrently, without complications. The graft reinforcement consisted of graft extension for eliminating occult type I endoleak, and relining for eliminating occult type…
A 15-Year Single-Center Experience of Endovascular Repair for Elective and Ruptured Abdominal Aortic Aneurysms
2016
Purpose: To evaluate the differences in technical outcomes and secondary interventions between elective endovascular aneurysm repair (el-EVAR) procedures and those for ruptured aneurysms (r-EVAR). Methods: Of the 906 patients treated with primary EVAR from September 1998 until July 2012, 43 cases were excluded owing to the use of first-generation stent-grafts. Among the remaining 863 patients, 773 (89.6%) patients (mean age 72 years; 697 men) with asymptomatic or symptomatic abdominal aortic aneurysms (AAAs) were assigned to the el-EVAR group; 90 (10.4%) patients (mean age 73 years; 73 men) were assigned to the r-EVAR group based on blood outside the aortic wall on preoperative imaging. Th…
Long-term results of simplified frozen elephant trunk technique in complicated acute type A aortic dissection: A case-control study.
2016
Aim To describe the long-term experience of a simplified frozen elephant trunk technique (sFETT) used in complicated acute type A aortic dissection (AAAD) treatment. Methods and results Between January 2001 and December 2012, 34 patients (mean age 59.9 ± 11.0 years) with complicated AAAD (DeBakey I) underwent an emergency surgery including sFETT. sFETT consisted in gluing the dissected aortic arch wall layers with gelatine-resorcinol adhesive and video-assisted antegrade open arch aortic stent-graft deployment in the arch or proximal descending aorta. In addition to sFETT, the aortic root was addressed with standard techniques. A 30-day mortality was 14.7% (five patients) due to bleeding (1…
Mid-term Results of Chimney and Periscope Grafts in Supra-aortic Branches in High Risk Patients
2017
Purpose Report mid-term outcomes of thoracic endovascular aneurysm repair (TEVAR) with chimney and periscope grafts (CPG) in supra-aortic branches (SAB). Methods Retrospective analysis, from October 2009 to May 2014, of patients with aneurysms requiring TEVAR with zone 0/1/2 proximal landing in association with at least one CPG in the SAB. All patients were considered at high risk for conventional surgery. Peri-operative mortality and morbidity, retrograde type A dissection, maximum aortic transverse diameter (TD) and its post-operative evolution, endoleak, survival, freedom from cardiovascular re-interventions, and CPG freedom from occlusion during the follow-up were analysed. Results Fort…
Hybrid Endograft Solution for Complex Iliac Anatomy
2010
The purpose of this study was to evaluate single-center results with selective use of Gore Excluder limbs (W.L. Gore & Associates, Flagstaff, AZ) in a Cook Zenith body (Cook Inc, Bloomington, IN) for elective endovascular abdominal aortic aneurysm (AAA) repair. A prospectively held database for patients with AAA, who were treated endovascularly between March 1999 and July 2008, was queried for patients treated with a Cook Zenith body and one or two Gore Excluder limbs. Indication, technical success, late limb occlusion, and disconnection were evaluated. From 276 patients who were treated with a Zenith body, 29 underwent repair with hybrid graft components with, in total, 41 Gore Exclud…