Search results for "ortography"

showing 10 items of 47 documents

Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable …

2020

The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography.From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media…

MaleTime FactorsRadiographymedicine.medical_treatmentContrast MediaPilot Projects030204 cardiovascular system & hematologyRadiography InterventionalEndovascular aneurysm repair030218 nuclear medicine & medical imagingEndovascular aortic repairAortic aneurysmPostoperative Complications0302 clinical medicineRisk FactorsIntravascular ultrasoundAortic aneurysm endovascular repair intravascular ultrasoundFluoroscopyAged 80 and overmedicine.diagnostic_testEndovascular ProceduresAngiographyGeneral MedicineMiddle AgedRadiation ExposureTreatment Outcomesurgical procedures operativecardiovascular systemendovascularFemaleRadiologyCardiology and Cardiovascular MedicineAdultmedicine.medical_specialtyAortographyOperative TimeRadiation DosageAortographyintravascular ultrasoundBlood Vessel Prosthesis Implantation03 medical and health sciencesText miningabdominal aortic aneurysmPredictive Value of TestsmedicineHumanscardiovascular diseasesUltrasonography InterventionalAgedRetrospective StudiesIVUSbusiness.industrymedicine.diseaseAngiographySurgerybusinessAortic Aneurysm AbdominalAbdominal surgeryAnnals of Vascular Surgery
researchProduct

Single-centre experience and preliminary Results of intravascular ultrasound in endovascular aneurysm repair

2019

Background Intravascular ultrasound (IVUS) has been introduced as diagnostic adjunct to provide new insights into the diagnosis and therapy of vascular disease. Herein, we compared the outcomes of conventional endovascular aneurysm repair (EVAR) and EVAR with IVUS in patients presenting with infrarenal abdominal aortic aneurysm using a propensity-matched cohort. Methods From May 2013 to August 2017, 221 patients were retrospectively analyzed. Of that, 122 patients were eligible for inclusion and underwent propensity score matching. Perioperative mortality and morbidity, renal function impairment, endoleak incidence, mean contrast medium usage, operative time, radiation exposure (including f…

MaleTime Factorsmedicine.medical_treatmentContrast MediaPredictive Value of TestEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysmRetrospective StudieRisk FactorsIntravascular ultrasoundFluoroscopyAged 80 and overmedicine.diagnostic_testEndovascular ProceduresGeneral MedicineMiddle AgedRadiation ExposureAbdominal aortic aneurysm2746 SurgeryTreatment OutcomeItalyFemaleRadiologyCardiology and Cardiovascular Medicinerenal function impairmentHumanPreliminary Datamedicine.medical_specialtyTime Factor610 Medicine & healthRadiation DosageAortography2705 Cardiology and Cardiovascular Medicineintravascular ultrasoundBlood Vessel Prosthesis ImplantationEndovascular aneurysm repaircontrast mediumPredictive Value of Testsmedicinefluoroscopy timeHumansUltrasonography InterventionalAgedRetrospective StudiesEndovascular Procedurebusiness.industryRisk FactorAngiography Digital SubtractionPerioperativeDigital subtraction angiographymedicine.disease10020 Clinic for Cardiac SurgeryAngiographySurgerybusinessAortic Aneurysm Abdominal
researchProduct

Fenestrated Stent Grafting for Short-necked and Juxtarenal Abdominal Aortic Aneurysm

2010

Objectives: To present an 8-year clinical experience in the endovascular treatment of short-necked and juxtarenal abdominal aortic aneurysm (AAA) with fenestrated stent grafts. Methods: At our tertiary referral centre, all patients treated with fenestrated and branched stent grafts have been enrolled in an investigational device protocol database. Patients with short-necked or juxtarenal AAA managed with fenestrated endovascular aneurysm repair (F-EVAR) between November 2001 and April 2009 were retrospectively reviewed. Patients treated at other hospitals under the supervision of the main author were excluded from the study. Patients treated for suprarenal or thoraco-abdominal aneurysms wer…

MaleTime Factorsmedicine.medical_treatmentShort neckFenestrated graftKaplan-Meier EstimateOPEN REPAIREndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysmEVARNetherlandsAged 80 and overMedicine(all)medicine.diagnostic_testENDOGRAFT REPAIRMiddle AgedJuxtarenalAbdominal aortic aneurysmProsthesis FailureTreatment OutcomeFemaleKidney DiseasesStentsCardiology and Cardiovascular MedicineReoperationmedicine.medical_specialtyAortographyArterial Occlusive DiseasesFenestrated graftsProsthesis DesignAortographyRisk AssessmentBlood Vessel Prosthesis ImplantationAneurysmRenal DialysisBlood vessel prosthesismedicineHumanscardiovascular diseasesAgedRetrospective Studiesbusiness.industryStentENDOVASCULAR REPAIRmedicine.diseaseAneurysmBlood Vessel ProsthesisSurgeryAbdominal aortic aneurysmSurgerybusinessTomography Spiral ComputedAortic Aneurysm AbdominalAbdominal surgeryEuropean Journal of Vascular and Endovascular Surgery
researchProduct

Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair: A Prospective Multi…

2020

Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-rel…

Malemedicine.medical_specialtyAortographyTime FactorsComputed Tomography Angiographymedicine.medical_treatmentComputed tomographyDiagnostic accuracy030204 cardiovascular system & hematology030230 surgeryLikelihood ratios in diagnostic testingEndovascular aneurysm repairAortography03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicinePostoperative ComplicationsPredictive Value of TestsColor duplex ultrasoundMultidetector Computed TomographymedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesUltrasonography Doppler ColorProspective cohort studyAgedAged 80 and overmedicine.diagnostic_testbusiness.industryEndovascular ProceduresReproducibility of Resultsmedicine.diseaseAbdominal aortic aneurysmTreatment OutcomeRetreatmentFemaleRadiologyFranceCardiology and Cardiovascular MedicinebusinessAortic Aneurysm AbdominalCirculation. Cardiovascular imaging
researchProduct

A clampless and sutureless aortic anastomosis technique using an endograft connector for aortoiliac occlusive disease in which the aorta cannot be cl…

2012

Bypass surgery in aortoiliac or aortofemoral occlusive disease can be technically demanding and hazardous due to huge calcifications and/or patient co-morbidities. We report about mid-term results of a telescoping sutureless aortic anastomosis technique using endografts as connectors to address such challenging situations. This is a single-center experience (2004–2011) in seven patients (63 ± 6 years) requiring aortoiliac (three) or aortofemoral (four) bypass surgery. In six cases, an aortic stent graft was telescoped into the infrarenal aorta and partly deployed within the aorta and partly outside the aorta. In the first case, a bifurcated stent graft was deployed and the iliac legs were …

Malemedicine.medical_specialtyPercutaneousTime Factorsmedicine.medical_treatmentAortic DiseasesAortoiliac occlusive diseaseArterial Occlusive Diseases610 Medicine & healthConstriction PathologicAnastomosisProsthesis DesignAortographyIliac Artery2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationPostoperative Complicationsmedicine.arterymedicineHumans2741 Radiology Nuclear Medicine and ImagingRadiology Nuclear Medicine and imagingVascular CalcificationAgedAortabusiness.industry10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresSuture TechniquesStentExternal iliac arteryGeneral MedicineMiddle Agedmedicine.diseaseConstrictionSurgeryBlood Vessel Prosthesis10020 Clinic for Cardiac Surgery2746 SurgeryStenosisTreatment OutcomeBypass surgerySurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray Computed
researchProduct

Endovascular treatment options for complex abdominal aortic aneurysms

2015

Abstract Purpose To report short-term and midterm outcomes of endovascular aneurysm repair (EVAR) of complex aneurysms requiring revascularization of visceral arteries. Materials and Methods Prospective data were collected from patients deemed unsuitable for conventional EVAR and conventional surgery who were treated with different endovascular approaches according to the clinical presentation of the aneurysm. Custom-made fenestrated endovascular aneurysm repair (CM f-EVAR) was used in the elective setting, homemade fenestrated endovascular aneurysm repair (HM f-EVAR) or HM f-EVAR combined with chimney endovascular aneurysm repair (ch-EVAR) was used in the emergent setting in patients with …

Malemedicine.medical_specialtyRadiology Nuclear Medicine and ImagingTime Factorsmedicine.medical_treatmentCustom-made fenestrated endovascular aneurysm repairProsthesis DesignRevascularizationAortographyEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareBlood Vessel Prosthesis ImplantationAortic aneurysmAneurysmBlood vessel prosthesismedicine.arterymedicineHumansRenal arterychimney endovascular aneurysm repairVascular PatencyAgedRetrospective StudiesAged 80 and overbusiness.industryhomemade fenestrated endovascular aneurysm repairEndovascular Procedureshomemade fenestrated endovascular aneurysm repair; Custom-made fenestrated endovascular aneurysm repair; chimney endovascular aneurysm repairPerioperativeMiddle Agedmedicine.diseaseBlood Vessel ProsthesisSurgeryVisceraTreatment OutcomeRegional Blood FlowFemaleStentsRadiologyTomography X-Ray ComputedbusinessCardiology and Cardiovascular MedicineBlood Flow VelocityAortic Aneurysm AbdominalAbdominal surgery
researchProduct

Three-Dimensional Analysis of Component Stability of the Nellix Endovascular Aneurysm Sealing System After Treatment of Infrarenal Abdominal Aortic A…

2016

Purpose: To assess short-term stability and conformational changes of the Nellix EndoVascular Aneurysm Sealing (EVAS) System using 3-dimensional (3D) analysis. Methods: Postoperative computed tomography (CT) scans obtained at 0, 3, and 12 months in 24 patients (mean age 75±7 years; 22 men) who underwent EVAS between December 2013 and December 2014 for intact abdominal aortic aneurysm (within the instructions for use) were evaluated for stent-graft deviation in multiple planes using dedicated 3D analysis software. In addition, 2D analysis using an anatomically fixed reference landmark was performed to assess craniocaudal migration. Clinical and follow-up data of the patients were recorded a…

Malemedicine.medical_specialtyThree dimensional analysisTime FactorsEndoleak3d analysisComputed tomography030204 cardiovascular system & hematologyProsthesis DesignAortography030218 nuclear medicine & medical imagingBlood Vessel Prosthesis Implantation03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineAneurysmForeign-Body MigrationPredictive Value of TestsHumansMedicineRadiology Nuclear Medicine and imagingAgedRetrospective StudiesComputed tomography angiographyAged 80 and overmedicine.diagnostic_testbusiness.industryEndovascular ProceduresMean ageMiddle Agedmedicine.diseaseAbdominal aortic aneurysmBlood Vessel ProsthesisTreatment OutcomeRadiographic Image Interpretation Computer-AssistedFemaleStentsSurgeryRadiologyCardiology and Cardiovascular MedicinebusinessAfter treatmentAortic Aneurysm AbdominalJournal of Endovascular Therapy
researchProduct

A minimally invasive approach for aortobifemoral bypass procedure

2011

Surgical aortobifemoral bypass procedure for aortoiliac occlusive disease remains the gold standard treatment despite rapidly expanding range of indications for endovascular repair. Besides several disadvantages such as dysparaesthesias, hernias, and unpleasant outcome, transperitoneal exposure of the aorta is also associated with operative autonomic nerve injury. In five male patients, infrarenal aorta was exposed through a small (8 cm) supraumbilical midline incision. Incision of the posterior peritoneum above the infrarenal aorta was limited to 3 cm. A 1 cm infraumbilical incision allowed transperitoneal placement of the distal aortic clamp outside of the operative field. Four centimeter…

Malemedicine.medical_specialtyTime FactorsAortic DiseasesAortoiliac occlusive diseaseArterial Occlusive DiseasesConstriction PathologicAnastomosisAortographyIliac ArteryBlood Vessel Prosthesis ImplantationPostoperative Complicationsmedicine.arterymedicineHospital dischargeHumansMinimally Invasive Surgical ProceduresAortaAgedAortaCentimeterbusiness.industryLength of StayMiddle Agedmedicine.diseaseConstrictionPatient DischargeSurgeryFemoral ArteryClampTreatment OutcomeAnesthesiaSurgeryCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedIntermediate careMagnetic Resonance AngiographyAbdominal surgeryJournal of Vascular Surgery
researchProduct

Periscope endograft technique to revascularize the left subclavian artery during thoracic endovascular aortic repair.

2013

To present early and midterm results of the periscope endograft (PG) technique to maintain left subclavian artery (LSA) blood flow in thoracic endovascular aortic repairs (TEVAR) involving zone 3.From April 2010 to January 2013, 14 consecutive high-risk patients (11 men; mean age 70±8 years, range 56-87) underwent TEVAR with the PG technique for 10 thoracic aortic aneurysms (TAA), 2 traumatic aortic ruptures, and 2 aortic dissections without a suitable landing zone (2 cm distal to the LSA). Five procedures were performed emergently for rupture (3 TAAs and the 2 trauma cases). Two patients had a periscope deployed in an aberrant right subclavian artery. The periscope endografts were sized 1 …

Malemedicine.medical_specialtyTime FactorsAortic RuptureSubclavian ArteryAorta ThoracicDissection (medical)Kaplan-Meier EstimateProsthesis DesignThoracic aortic aneurysmAortographyAortic aneurysmBlood Vessel Prosthesis ImplantationAneurysmPostoperative ComplicationsBlood vessel prosthesismedicine.arterymedicineThoracic aortaHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesVascular PatencyAgedAged 80 and overAortaAortic Aneurysm Thoracicbusiness.industryEndovascular ProceduresMiddle Agedmedicine.diseaseSurgeryBlood Vessel ProsthesisAortic Dissectionsurgical procedures operativeTreatment OutcomeCardiothoracic surgerycardiovascular systemSurgeryFemaleRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Use of covered chimney stents for pararenal aortic pathologies is safe and feasible with excellent patency and low incidence of endoleaks.

2012

Background To present the clinical experience of consecutive series with use of balloon-expandable and self-expanding chimney endografts (balloon-expandable covered stent group [BECS] vs self-expanding covered stent group [SECS]) in the endovascular treatment of challenging aortic pathologies requiring renal and/or visceral revascularization. Methods Between January 2009 and May 2011, data for 37 high-risk patients from one center and 35 patients from another institution, with pararenal aortic pathologies treated by the chimney endovascular technique, were prospectively collected. The chimney-graft technique is based on the deployment of a covered or bare-metal stent parallel to the aortic …

Malemedicine.medical_specialtyTime FactorsEndoleakmedicine.medical_treatmentEVAR aneurysm chimney periscopesAortic Diseases610 Medicine & healthKaplan-Meier EstimateRevascularizationBalloonProsthesis DesignSettore MED/22 - Chirurgia VascolareAortographyRisk Assessment2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationPredictive Value of TestsRisk FactorsAngioplastyGermanymedicineHumansVascular PatencyComputed tomography angiographyAgedRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryStentPerioperativemedicine.disease10020 Clinic for Cardiac Surgery2746 SurgerySurgeryBlood Vessel ProsthesisStenosisTreatment OutcomeCuffSurgeryFemaleStentsRadiologyCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedAngioplasty BalloonSwitzerlandJournal of vascular surgery
researchProduct