Search results for "osteosynthesis"

showing 10 items of 46 documents

Dynamische Analyse von Osteosynthesen am Olecranon: ein in-vitro Vergleich zweier Osteosynthesesysteme / Dynamic analysis of olecranon osteosyntheses…

2008

INTRODUCTION The aim of the present study was to develop a test setup with continuous angle alteration to imitate elbow joint motion for the mechanical evaluation of tension band wiring and a newly designed intramedullary nail. MATERIALS AND METHODS The servo-pneumatical test stand worked with a rotational angle-adjusted and a linear force-adjusted engine. The fracture model was dynamically tested under cyclic loading imitating elbow joint motion. In total, 14 fresh cadaver upper extremities underwent olecranon fracture by means of transverse osteotomy and were assigned to two groups: tension band wiring and intramedullary nailing. There was a continuous angle alteration between 0 and 1000 …

OrthodonticsMaterials scienceOsteosynthesisTension band wiringOlecranonElbowBiomedical Engineeringmedicine.diseaselaw.inventionIntramedullary rodmedicine.anatomical_structureOlecranon fracturelawFracture fixationmedicineDisplacement (orthopedic surgery)Biomedizinische Technik/Biomedical Engineering
researchProduct

Osteosynthese am proximalen Humerus mittels winkelstabiler Platte oder Doppelplatte: eine vergleichende biomechanische Untersuchung / Angle-fixed pla…

2008

Internal fixation of fractures of the proximal humerus needs a high stability of fixation to avoid secondary loss of fixation. This is especially important in osteoporotic bone. In an experimental study, the biomechanical properties of the angle-fixed Philos plate (internal fixator) and a double-plate osteosynthesis using two one-third tubular plates were assessed. The fracture model was an unstable three-part fracture (AO type B2). Eight pairs of human cadaveric humeri were submitted to axial load and torque. In the first part of the study, it was assessed to which degree the original stiffness of the humeri could be restored after the osteotomy by the osteosynthesis procedure. Subsequentl…

OrthodonticsOsteosynthesismedicine.medical_treatmentBiomedical EngineeringBiomechanicsAnatomyOsteotomymedicine.anatomical_structureFracture fixationBone platemedicineInternal fixationHumerusCadaveric spasmBiomedizinische Technik/Biomedical Engineering
researchProduct

Photoelastic analysis of conventional and locking system for treatment of mandibular angle fractures with a single plate

2021

Made available in DSpace on 2021-06-25T10:28:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2021-04-01 Background: This photoelastic analysis evaluated stress distribution in different osteosynthesis systems, conventional and locking, used for treatment of mandibular angle fractures with a single plate. Material and Methods: Angle fractures were simulated in mandibles made of photoelastic resin. Following Champy’s method, plate osteosynthesis was performed. The samples were divided into five groups: Group 1, non-fractured mandible; Group 2, two screws were installed in each segment using a conventional system; Group 3, two screws were installed in each segment using a locking system; …

OrthodonticsPhotoelasticityUniversal testing machineOsteosynthesisMaterials scienceResearchMandibular fractureMandibleInternal fracture fixation030206 dentistrymedicine.diseaseMandibular first molarbone platesStress (mechanics)03 medical and health sciences0302 clinical medicinemandibular fractureBone platemedicineOral Surgery030223 otorhinolaryngologyosteosynthesisGeneral DentistryUNESCO:CIENCIAS MÉDICAS
researchProduct

Retrograde nailing versus locking plate osteosynthesis of proximal humeral fractures: a biomechanical study

2011

Background In locking plate osteosynthesis of proximal humeral fractures, secondary varus malalignment is a specific complication. Retron nails (Tantum AG, Neumunster, Germany), among others, have been designed to improve medial support of the calcar humeri. The aim of our biomechanical study was to examine whether Retron nails provide increased stiffness for axial loads and adequate stiffness for torsional loads when compared with Philos plates (Synthes AG, Umkirch, Germany). Materials and methods Twenty-two fresh-frozen paired humeri were collected. After potting the specimens, intact bones were exposed to sinusoidal axial (10-120 N) and torsional (±2.5 Nm) loading for 8 cycles to calcula…

Orthodonticsanimal structuresOsteosynthesisCalcarbusiness.industryBone ScrewsVarus malalignmentStiffnessGeneral MedicineAnatomyBone NailsProsthesis DesignBiomechanical PhenomenaLocking plateRadiographyFracture Fixation InternalHumeral fractureShoulder FracturesHumansMedicineOrthopedics and Sports MedicineSurgerymedicine.symptombusinessBone PlatesJournal of Shoulder and Elbow Surgery
researchProduct

A Clinical Comparison between the Gamma® and the Claufitt® Nails in Unstable Proximal Femoral Fractures

2007

Purpose To assess the differences that exist between two intramedullary osteosynthesis systems for the treatment of unstable proximal femoral fractures in an attempt to find out whether the use of an antirotation screw improves the final result. Materials and methods A retrospective study was carried out to analyze the plcement and clinical evolution of both intramedullary nailing systems (Gamma ® y Claufitt ® ). The patients’ medium-term functional status was evaluated and benchmarked against the characteristics of the population served by our University Hospital. A final database was obtained made up of 43 cases of Claufitt ® that met the criteria of our study. A functional assessment sys…

Orthodonticseducation.field_of_studyOsteosynthesisbusiness.industryPopulationRetrospective cohort studyUniversity hospitallaw.inventionIntramedullary rodlawEvaluation methodsMedicineOrthopedics and Sports MedicineSurgeryFunctional statuseducationbusinessRevista Española de Cirugía Ortopédica y Traumatología (English Edition)
researchProduct

Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: A biomechanical study

2010

Abstract Background The purpose of this study was to compare the stability of a 2.4 mm palmar locking compression plate and a new intramedullary nail-plate-hybrid Targon DR for dorsally comminuted distal radius fractures. Methods An extraarticular 10 mm dorsally open wedge osteotomy was created in 8 pairs of fresh frozen human radii to simulate an AO–A3-fracture. The fractures were stabilized using one of the fixation methods. The specimens were loaded axially with 200 N and dorsal-excentrically with 80 N. 2000 cycles of dynamic loading and axial loading-to-failure were performed. Findings Axial loading revealed that intramedullary osteosynthesis (Targon DR: 369 N/mm) was significantly ( p …

Orthodonticsmedicine.medical_specialtyMaterials scienceOsteosynthesisBiophysicsRadiusLocked platingIn Vitro TechniquesCompression (physics)Biomechanical PhenomenaFracture Fixation Intramedullarylaw.inventionSurgeryIntramedullary rodFracture Fixation InternalFixation (surgical)lawLoad to failureFresh frozenmedicineHumansOrthopedics and Sports MedicineRadius FracturesBone PlatesFractures ComminutedClinical Biomechanics
researchProduct

Bone Augmentation in Dental Implantology Using Press-Fit Bone Cylinders and Twin-Principle Diamond Hollow Drills: A Case Series

2009

Background: Bone transplants are mostly prepared with cutting drills, chisels, and rasps. These techniques are difficult for unexperienced surgeons, and the implant interface is less precise due to unstandardized preparation. Cylindrical bone transplants are a known alternative. Current techniques include fixation methods with osteosynthesis screws or the dental implant. Purpose: A new bone cylinder transplant technique is presented using a twin-drill principle resulting in a customized pressfit of the transplant without fixation devices and combining this with the superior grinding properties of a diamond coating. Materials and Methods: New cylindrical diamond hollow drills are used for cu…

OsteosynthesisMaterials sciencebusiness.industrymedicine.medical_treatmentDiamondDentistryengineering.materialDental instrumentsBone augmentationFixation (surgical)surgical procedures operativeDental implantologymedicineengineeringImplantOral SurgeryDental implantbusinessGeneral DentistryClinical Implant Dentistry and Related Research
researchProduct

Lesión compleja del codo pediátrico: fractura de cóndilo externo asociada a luxación posteromedial de codo.

2020

espanolAntecedentes y objetivo: La fractura de condilo externo asociada a una luxacion posteromedial de codo es una entidad muy rara, de la cual existen muy pocos casos publicados. Nuestro objetivo es presentar un caso complejo tratado en nuestro centro, el diagnostico, el tratamiento elegido, y el seguimiento a las 9 semanas. Caso clinico: varon de 5 anos con una luxacion posteromedial de codo asociada a una fractura de condilo externo, diagnosticada mediante TC y tratada de forma quirurgica mediante un abordaje anterior sobre el codo, reduccion abierta y osteosintesis con agujas de Kirschner. Resultados: los resultados clinicos y radiologicos a las 9 semanas son excelentes, presentando un…

PharmacologyOsteosynthesisbusiness.industryRare entity:CIENCIAS MÉDICAS [UNESCO]CondyleElbow dislocationJoint mobilityUNESCO::CIENCIAS MÉDICASMedicineAnterior approachSurgical treatmentNuclear medicinebusinessHumeral condyle
researchProduct

Biomechanische Untersuchungen verschiedener Osteosynthesen an der proximalen Tibia - Vorstellung einer neuartigen meßgeometrischen Anordnung. Biomech…

2003

In this article a new measuring system for biomechanical studies of various osteosynthesis procedures on the tibia is described. The paired tibias are osteotomized and embedded in PMMA in accordance with a randomization protocol. Testing is then carried out under nonaxial loading at 350 N, 600 N and 900 N, uniaxial bending applying a force of 12 Nm, and torsion at a force of 5 Nm in a universal pneumatic testing machine. Ultrasonic sensors pick up movement at the fracture gap under external loading. Testing of the measuring setup has been successful, and relevant results were obtained.

Proximal tibiaMaterials scienceOsteosynthesisBiomedical EngineeringTorsion (mechanics)Ultrasonic sensorTibiaBiomedical engineeringBiomedizinische Technik/Biomedical Engineering
researchProduct

Volar and dorsal mid-shaft forearm plating using DCP and LC-DCP: interference with the interosseous membrane and forearm-kinematics.

2010

Purpose To clarify if dorsal plate osteosynthesis of the forearm shaft is associated with impingement of the interosseous membrane (IOM) and if rotational kinematics of the forearm are influenced. Background Forearm fractures are treated by separate incisions. Osteosynthesis via one approach in proximal forearm fractures was associated with higher rates of synostosis. It has been claimed that this is due to IOM impingement. Materials and methods 16 forearms of fresh frozen cadavers were dissected until only radius, ulna and the IOM remained. To preserve physiological forearm rotation, the elbow joint, the distal radio-ulnar joint and the carpus remained intact. In group 1, LC-DC and DC plat…

RotationElbowBone ScrewsProsthesis DesignSupinationFracture Fixation InternalForearmCadaverFracture fixationBone platemedicineCadaverHumansPronationAgedOsteosynthesisbusiness.industryInterosseous membraneUlnaForearm InjuriesGeneral MedicineAnatomyUlna FracturesBiomechanical Phenomenabody regionsForearmmedicine.anatomical_structureSurgerybusinessRadius FracturesBone PlatesActa chirurgica Belgica
researchProduct