Search results for "oxygen saturation"
showing 10 items of 72 documents
Predicting hypoxia in cystic fibrosis patients during exposure to high altitudes
2006
Abstract Background For patients with cystic fibrosis (CF)-related partial respiratory insufficiency and reduced arterial oxygen tension at ground level, the mild hypobaric environment on commercial jet aircraft poses the risk of severe hypoxemia. Thus, physicians should be able to estimate the extent of in-flight hypoxia. Objectives To derive tools for estimating the expected drop in arterial oxygen partial pressure (paO 2 ) and oxygen saturation (saO 2 ) in young adult CF patients with mild to moderate airway obstruction during exposure to the hypobaric conditions aboard commercial aircraft and to test the predictive power of a hypobaric chamber simulation. Methods Blood gases of 12 CF pa…
Two-rescuer CPR results in hyperventilation in the ventilating rescuer.
2005
The "Guidelines 2000 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care--International Consensus on Science" recommend a tidal ventilation volume of 10 ml/kg body-weight without the use of supplemental oxygen during two-rescuer adult cardiopulmonary resuscitation (CPR). This relates to a ventilation volume of about 6.4 l/min. Additionally, the first aid provider ventilating the victim will breathe for him/herself during the external chest compression period adding another 3.2 l/min of ventilation. Finally, a deep breath is recommended before each ventilation to increase the end-expiratory oxygen concentration of the air exhaled. To investigate the effects of these recommend…
Improvement in altitude performance test after further acclimatization in pre-acclimatized soldiers.
2013
The Altitude Performance Test is a measure designed to assess an individual's degree of acclimatization to reduce the risk of acute mountain sickness during high-altitude activities. The aim of this study was to investigate the hypothesis that test results will improve in pre-acclimatized soldiers after several days of further acclimatization. The Altitude Performance Test consists of an uphill run at high altitude. The event is timed and performed with continuous oxygen saturation (SpO2) monitoring. The individual's time and lowest SpO2 measurement are recorded. This test was performed on the first day of arriving at 11,060 ft, and after 9 days at the same location. The 37 male soldiers we…
Changes in cerebral oxygen saturation following prone positioning for orthopaedic surgery under general anaesthesia: a prospective observational stud…
2015
Prone positioning is often necessary in orthopaedic surgery. The prone position, however, may result in impaired cerebral venous drainage with a subsequent reduction in cerebral perfusion. As a consequence, cerebral hypoxia may occur with the potential for neurological impairment.We assessed the changes in cerebral oxygen saturation with near-infrared spectroscopy using two different monitors after positioning the patient from supine to prone.Prospective observational study.Primary Care University Hospital, from May 2010 to February 2011.Forty patients undergoing general anaesthetic procedures, of which 35 completed the investigation. Similar measurements were done in 35 volunteers, who wer…
Measurement of Cortical Microcirculation During Intracranial Aneurysm Surgery by Combined Laser-Doppler Flowmetry and Photospectrometry
2011
Accidental vessel occlusion is one major risk of intracranial aneurysm surgery potentially causing cerebral ischemia. The intraoperative assessment of cerebral ischemia remains a technological challenge.As a novel approach, cortical tissue integrity was monitored using simultaneous measurements of regional capillary-venous cerebral blood flow (rvCBF), oxygen saturation (Srvo2), and hemoglobin amount (rvHb) during aneurysm surgery.Fifteen patients scheduled for aneurysm surgery of the anterior and posterior circulation were included. A fiber optic probe was placed on the cortex associated with the distal branch of the aneurysmatic vessel. Blinded measurements by combined laser-Doppler flowme…
Influence of Training Models at 3,900-m Altitude on the Physiological Response and Performance of a Professional Wheelchair Athlete: A Case Study.
2019
Sanz-Quinto, S, Lopez-Grueso, R, Brizuela, G, Flatt, AA, and Moya-Ramon, M. Influence of training models at 3,900-m altitude on the physiological response and performance of a professional wheelchair athlete: A case study. J Strength Cond Res 33(6): 1715-1723, 2019-This case study compared the effects of two training camps using flexible planning (FP) vs. inflexible planning (IP) at 3,860-m altitude on physiological and performance responses of an elite marathon wheelchair athlete with Charcot-Marie-Tooth disease (CMT). During IP, the athlete completed preplanned training sessions. During FP, training was adjusted based on vagally mediated heart rate variability (HRV) with specific sessions…
Multimodal Device for Real-Time Monitoring of Skin Oxygen Saturation and Microcirculation Function
2019
The present study introduces a recently developed compact hybrid device for real-time monitoring of skin oxygen saturation and temperature distribution. The prototype involves a snapshot hyperspectral camera, multi-wavelength illuminator, thermal camera, and built-in computer with custom-developed software. To validate this device in-vivo we performed upper arm vascular occlusion on eight healthy volunteers. Palm skin oxygen saturation maps were analyzed in real-time using k-means segmentation algorithm and two-layer optical diffuse model. The prototype system demonstrated a satisfying performance of skin hyperspectral measurements in the spectral range of 507&ndash
LED-bed therapy of cardiovascular disorders: a volunteer study
2020
Studies of the physiological response of human half-body illumination by a specially designed bed comprising large number of LEDs emitting in the red and near infrared spectral range were carried out in a group of 32 volunteers comprising healthy subjects and hypertension patients. Blood pressure, heart rate and arterial blood oxygen saturation, as well as the bed surface temperature were continuously monitored during the measurement sessions with and without aluminum foil cover on the bed surface. None of the volunteers exhibited any notable changes in the heart rate and blood oxygenation during the procedures. The LightStim LED-bed session did not produce changes of arterial pressure in n…
Artificial ventilation for basic life support leads to hyperventilation in first aid providers.
2003
The 'Guidelines 2000 for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care - International Consensus on Science' recommend an artificial ventilation volume of 10 ml/kg bodyweight (equivalent to a tidal volume of 700-1000 ml) without the use of supplemental oxygen in adults with respiratory arrest. For first aid providers using the mouth-to-mouth or mouth-to-nose-ventilation technique, respectively, a ventilation volume of approximately 9.6 l/min results. Additionally, a deep breath is recommended before each ventilation to increase the end-expiratory oxygen concentration of the air exhaled by the first aid provider. To investigate the effects of these recommendations in health…
Meiofauna ratios as environmental indicators in the profundal depths of large lakes.
1995
Two sets of samples from Lake Paijanne and one from Lake Ladoga were used to examine the relations between the meiofauna and environmental variables. The most obvious indicators of an unpolluted environment were, in order of importance, the true meiofauna/total meiofauna ratio, the proportion of Aeolosomatidae, the proportion of Harpacticoida (excluding C. staphylinus), the meiofauna/macrofauna biomass ratio, the proportion of Naididae and the A. crassa + P. schmeili/true meiofauna ratio. Conversely, the clearest indicators of a polluted environment were the proportion of resting stages of Cyclopinae, the Nematoda/non-resting Copepoda ratio, and the proportions of Tubificidae, Oligochaeta, …