Search results for "pachymetry"

showing 10 items of 16 documents

Genome-wide association analyses identify multiple loci associated with central corneal thickness and keratoconus

2013

The author manuscript of this article is open access and is freely available online at PubMed Central

medicine.medical_specialtyKeratoconusCorneal Pachymetrygenetic structuresthickness; keratoconus; geneGlaucomaOcular hypertensionGenome-wide association studyBiologyReal-Time Polymerase Chain ReactionKeratoconusWhite PeopleArticleCentral corneal thicknessCorneaAsian PeopleOphthalmologyCorneaOdds RatioGeneticsmedicineHumansCorneal pachymetrymedicine.diagnostic_testForkhead Box Protein O1Forkhead Transcription FactorsGlaucomaOdds ratioMicroarray Analysismedicine.diseaseConfidence intervaleye diseasesFibronectinsmedicine.anatomical_structureGenetic Locisense organsGenome-Wide Association Study
researchProduct

Assessment of modifications in thickness, curvatures, and volume upon the cornea caused by disposable soft contact lens wear.

2015

Purpose To assess the effect of different disposable soft contact lenses on several corneal parameters–-thickness, anterior and posterior curvature, and volume–-by means of a Scheimpflug imaging-based device (Pentacam HR). Diurnal variations of these parameters were taken into account. Methods Twenty-one young, healthy subjects wore 4 different types of daily disposable soft contact lenses on 4 different days: Dailies AquaComfort Plus, SofLens, Dailies Total1, and Acuvue TruEye. The lenses had different material and water content. Pachymetry and curvature maps and corneal volume values were obtained using the Pentacam HR twice a day: one before putting the lens on and one after an 8-hour pe…

AdultMaleEffects of long-term contact lens wear on the corneaMaterials sciencegenetic structuresCorneal PachymetryScheimpflug principleVisual AcuityCurvatureCorneaYoung AdultOpticsCorneamedicineMyopiaHumansCorneal pachymetryDisposable Equipmentmedicine.diagnostic_testbusiness.industryCorneal TopographyGeneral MedicineOrgan SizeCorneal topographyContact Lenses Hydrophiliceye diseasesCircadian RhythmContact lensOphthalmologymedicine.anatomical_structureFemalesense organsDisposable EquipmentbusinessBiomedical engineeringEuropean journal of ophthalmology
researchProduct

Corneal thickness differences between type 2 diabetes and non-diabetes subjects during preoperative laser surgery examination

2016

Aims To evaluate the differences in corneal thickness between type 2 diabetes subjects with HbA1c under 7.0% and non-diabetes subjects during their preoperative laser surgery examinations. Methods The mean of five consecutive corneal thickness measurements at the central and mid-peripheral cornea was obtained by means of noncontact scanning-slit corneal topography (Orbscan Topography System II; Orbscan, Inc., Salt Lake City, UT, USA) in 35 myopic non-insulin dependent type 2 diabetes subjects (17 males and 18 females) and 48 healthy myopic controls (23 males and 25 females). Results The corneal thickness values at the central and mid-peripheral cornea were significantly higher in the diabet…

Laser surgeryAdultMalemedicine.medical_specialtyCorneal Pachymetrygenetic structuresEndocrinology Diabetes and Metabolismmedicine.medical_treatment030209 endocrinology & metabolismType 2 diabetesPhotorefractive KeratectomyCornea03 medical and health sciencesLaser refractive surgery0302 clinical medicineEndocrinologyDiabetes mellitusRefractive surgeryOphthalmologyCorneaInternal MedicinemedicineMyopiaHumansProspective StudiesScanning-slit corneal topographyGlycated HemoglobinQuantitative anatomyDiabetic Retinopathymedicine.diagnostic_testbusiness.industryEndothelium CornealCorneal TopographyType 2 diabetesmedicine.diseaseControl subjectsCorneal topographyeye diseasesSurgeryCorneal thicknessmedicine.anatomical_structureDiabetes Mellitus Type 2Preoperative Period030221 ophthalmology & optometryFemaleLasers Excimersense organsbusinessBody mass index
researchProduct

Intrasubject repeatability of corneal power, thickness, and wavefront aberrations with a new version of a dual rotating Scheimpflug–Placido system

2014

Purpose To determine the intrasubject repeatability of a recently introduced dual-camera rotating Scheimpflug–Placido imaging system (Galilei G4) in determining corneal thickness, power, and wavefront aberrations in young healthy subjects. Setting University of Valencia, Valencia, Spain. Design Prospective evaluation of diagnostic technology. Methods The study comprised right eyes of 25 subjects aged 20 to 40 years with a spherical equivalent ranging from −4.25 to +1.00 diopters. The central corneal thickness, thinnest point value and location, anterior and posterior surface curvatures, total corneal power, and corneal wavefront aberrations were measured for distance vision using the dual S…

AdultMaleChord (geometry)medicine.medical_specialtyCorneal Wavefront AberrationCorneal Pachymetrygenetic structuresIntraclass correlationScheimpflug principleDiagnostic Techniques OphthalmologicalAstigmatismRefraction OcularCorneaYoung AdultOpticsOphthalmologyPhotographymedicineHumansProspective StudiesCorneal pachymetryDioptreMathematicsObserver VariationWavefrontmedicine.diagnostic_testbusiness.industryReproducibility of ResultsRepeatabilitymedicine.diseaseHealthy Volunteerseye diseasesSensory SystemsOphthalmologyFemaleSurgerysense organsbusinessJournal of Cataract and Refractive Surgery
researchProduct

Determination of corneal volume from anterior topography and topographic pachymetry: application to healthy and keratoconic eyes

2009

Purpose: To describe a method to measure corneal volume from topography and pachymetry, and test its clinical use on a sample of healthy human subjects and a case of circumscribed posterior keratoconus. Methods: Corneal curvature (PCT 200® corneal topography system; Optopol Technology SA, Zawiercie, Poland) and ultrasonic topographic pachometry on 25 points (Ophthasonic ® A-Scan/Pachometer III; Teknar Inc., St Louis, MO, USA) were measured on each of 12 young healthy corneas and one cornea suffering from circumscribed posterior keratoconus. Topography and pachymetry data were used to calculate the coordinates for the corresponding points on the posterior surface of the cornea. TableCurve 3D…

MaleKeratoconusmedicine.medical_specialtygenetic structuresEye diseaseKeratoconusSensitivity and SpecificityCorneaYoung Adult03 medical and health sciences0302 clinical medicineCorneaOphthalmologymedicineHumansPosterior keratoconusCorneal pachymetry030304 developmental biology0303 health sciencesmedicine.diagnostic_testbusiness.industryCorneal TopographyCorneal topographymedicine.diseaseeye diseasesSensory SystemsOphthalmologymedicine.anatomical_structure030221 ophthalmology & optometryFemalesense organsTomographybusinessTomography Optical CoherenceOptometryVolume (compression)Ophthalmic and Physiological Optics
researchProduct

Quantitative corneal anatomy: evaluation of the effect of diabetes duration on the endothelial cell density and corneal thickness.

2014

Purpose To evaluate the differences in endothelial cell density (ECD) and central corneal thickness (CCT) between type II diabetic patients and age-matched healthy controls, and determine the impact of time from diagnosis. Methods This is a comparative study of 77 eyes of type II diabetic patients (33 males, 44 females) and 80 eyes of healthy subjects (42 males, and 38 females) whose ages ranged from 38 to 56 years. CCT, ECD, HbA1c levels, and Goldmann tonometry were measured. Results The CCT was significantly higher and the ECD significantly lower in long-term diabetic patients (10 years + since diagnosis) when compared with short-term diabetic patients (<1 year since diagnosis) and contro…

Diabetes durationAdultMalemedicine.medical_specialtyTime Factorsgenetic structuresCorneal PachymetryCell CountType ii diabetesCorneaHba1c levelOphthalmologyInternal medicineMedicineHumansRetrospective StudiesGlycated Hemoglobinbusiness.industryEndothelium CornealHealthy subjectsMiddle AgedCorneal structureeye diseasesSensory SystemsEndothelial cell densityGoldmann tonometryOphthalmologyEndocrinologyDiabetes Mellitus Type 2Disease ProgressionFemalesense organsAnalysis of variancebusinessOptometryOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Agreement between intraoperative anterior segment spectral-domain OCT and 2 swept-source OCT biometers.

2021

Purpose: To evaluate the agreement of different biometric parameters obtained using intraoperative spectral-domain optical coherence tomography (SD-OCT) and two swept-source optical coherence tomog...

MaleBiometryCorneal PachymetryPhysics::Medical PhysicsBiomedical EngineeringSpectral domain030204 cardiovascular system & hematology03 medical and health sciences0302 clinical medicineOpticsOptical coherence tomographyAnterior Eye SegmentLens CrystallinemedicineHumansAgedPhysicsAged 80 and overmedicine.diagnostic_testbusiness.industryReproducibility of ResultsGeneral MedicineCoherence (statistics)Middle AgedAxial Length EyeOptical biometerSurgeryFemalebusiness030217 neurology & neurosurgeryTomography Optical CoherenceExpert review of medical devices
researchProduct

Axial Length and Anterior Segment Alterations in Former Preterm Infants and Full-Term Neonates Analyzed With Scheimpflug Imaging.

2017

Purpose To compare the axial length and anterior segment alterations in preterm infants with and without retinopathy of prematurity with those of full-term infants. Methods The Wiesbaden Prematurity Study investigated 503 participants of former gestational age ≤32 weeks and gestational age ≥37 weeks now being aged 4 to 10 years. This study included 485 participants in the prospective controlled cross-sectional, hospital-based study with successful Pentacam Scheimpflug imaging. Anterior segment parameters, axial length measurements, and associated factors were analyzed. Results Corneal thickness did not differ between former preterm and full-term infants. Significant differences were found b…

Diagnostic ImagingMalePediatricsmedicine.medical_specialtyCorneal PachymetryTerm BirthBirth weightVisual AcuityGestational AgeAstigmatismRefraction Ocular03 medical and health sciences0302 clinical medicineAnterior Eye SegmentMedicineBirth WeightHumansProspective StudiesCorneal pachymetryChildFull Termmedicine.diagnostic_testbusiness.industryGestational ageRetinopathy of prematurityInfant Low Birth Weightmedicine.diseaseRefractive ErrorsOphthalmologyLow birth weightAxial Length EyeCross-Sectional Studies030221 ophthalmology & optometryTerm BirthFemalemedicine.symptombusiness030217 neurology & neurosurgeryInfant PrematureCornea
researchProduct

Retroespalhamento luminoso das córneas de pacientes com diabete melito dependente e não dependente de insulina: estudo piloto

2017

ABSTRACT Purpose: To compare central corneal backscatter obtained from Scheimpflug images between patients with insulin-dependent and non-insulin-dependent diabetes mellitus (IDDM and NIDDM, respectively) and healthy controls. Methods: Seven patients with IDDM (7 eyes), eleven patients with NIDDM (11 eyes), and sixteen healthy subjects (16 eyes) were included in this pilot study. Scheimpflug imaging system (Pentacam, Oculus Inc., Germany) was used to obtain optical sections of the cornea. Seven meridians were analyzed for each eye, oriented from 70° to 110°. Optical density values for the central 3-mm and 5-mm zones of the cornea were obtained by image analysis using external software. Resu…

MaleVisual acuityCorneal Pachymetrygenetic structuresScheimpflug principleVisual AcuityPilot ProjectsDiagnostic Techniques OphthalmologicalCorneal DiseasesCornea0302 clinical medicineDiabetes mellituslcsh:OphthalmologyReference ValuesCorneaMedicineCorneal pachymetrymedicine.diagnostic_testCorneal DiseasesAge FactorsScheimpflug imagingGeneral MedicineMiddle AgedCorneal topographymedicine.anatomical_structureDiabetes mellitus tipo 2Diabetes mellitus tipo 1Femalemedicine.symptomAdultmedicine.medical_specialtyProjetos pilotoStatistics Nonparametric03 medical and health sciencesAnterior Eye SegmentDiabetes mellitusOphthalmologyHumansScheimpflug Topografia da córneaAgedbusiness.industryCase-control studyReproducibility of ResultsDiabetes mellitus type 1Diabetes mellitus type 2medicine.diseaseeye diseasesOphthalmologyPilot projectDiabetes Mellitus Type 1Diabetes Mellitus Type 2lcsh:RE1-994Case-Control Studies030221 ophthalmology & optometrysense organsCorneal topographybusiness030217 neurology & neurosurgery
researchProduct

Orbscan Pachymetry: Differences between observers when carrying out measurements of the corneal thickness

2005

espanolObjetivo: Estudiar el espesor corneal y la variabilidad entre observadores de las mediciones del espesor corneal empleando paquimetria Orbscan. Metodos: Analizamos el espesor corneal central y paracentral de 30 sujetos (n=30) cuya edad oscilaba entre 19 y 38 anos (media 27,27 D.E. 5,25) con el Sistema Topografico Orbscan II (Orbscan, Inc., Salt Lake City, UT, USA). La media de cinco mediciones consecutivas del espesor corneal fue obtenida por dos diferentes observadores. Los resultados obtenidos por los dos observadores se compararon. Resultados: No se encontraron diferencias significativas entre los valores medios del espesor corneal de los observadores en la cornea central (p=0,749…

Physicsmedicine.medical_specialtycorneal thicknessSalt lakeCórneaCorneaOphthalmologymedicine.anatomical_structureOrbscanCorneaOphthalmologymedicinepachymetryOrbscan iiCartographypaquimetríaespesor corneal
researchProduct