Search results for "particle detector"
showing 10 items of 200 documents
High $p_{T}$ Leptons and W Production at HERA
1999
Details are given of the observation by H1 of events containing high P_T leptons in addition to large missing P_T. A closely related ZEUS analysis, including a preliminary measurement of the W production cross section, is discussed and the two experiments are compared. Some possible non-Standard Model sources for the events are considered.
Kalman filter tracking and vertexing in a silicon detector for neutrino physics
2002
Abstract This article describes the application of Kalman filter techniques for the tracking and vertexing of particles inside the NOMAD-STAR detector, a silicon vertex detector installed in NOMAD, one of the neutrino oscillation experiments at the CERN-SPS. The use of the Kalman filter simplifies computationally the tracking and vertex procedure for NOMAD-STAR. The alignment of NOMAD-STAR is shown as an example of the application of the Kalman filter for tracking purposes. The accuracy of the method is such that one obtains alignment residuals between 9 and 12 μm . Furthermore, a preliminary measure of the impact parameter (with an RMS ∼36 μm ) illustrates the vertexing capabilities of thi…
A luminosity monitor for the A4 parity violation experiment at MAMI
2005
A water Cherenkov luminosity monitor system with associated electronics has been developed for the A4 parity violation experiment at MAMI. The detector system measures the luminosity of the hydrogen target hit by the MAMI electron beam and monitors the stability of the liquid hydrogen target. Both is required for the precise study of the count rate asymmetries in the scattering of longitudinally polarized electrons on unpolarized protons. Any helicity correlated fluctuation of the target density leads to false asymmetries. The performance of the luminosity monitor, investigated in about 2000 hours with electron beam, and the results of its application in the A4 experiment are presented.
Use of aluminum nitride for UV radiation dosimetry
2007
Abstract An investigation of AlN ceramics for applications in UV radiation detection shows the advantages of using the 480 nm emission band for optically stimulated luminescence signal detection instead of the previously used 400 nm emission band since the rate of decrease of the response signal at room temperature is lower than that of the 400 nm band, and its excitation region falls in the UV-B range.
Digital pulse-timing technique for the neutron detector array NEDA
2015
WOS: 000348040900011
Investigation of Hamamatsu H8500 phototubes as single photon detectors
2015
We have investigated the response of a significant sample of Hamamatsu H8500 MultiAnode PhotoMultiplier Tubes (MAPMTs) as single photon detectors, in view of their use in a ring imaging Cherenkov counter for the CLAS12 spectrometer at the Thomas Jefferson National Accelerator Facility. For this, a laser working at 407.2 nm wavelength was employed. The sample is divided equally into standard window type, with a spectral response in the visible light region, and UV-enhanced window type MAPMTs. The studies confirm the suitability of these MAPMTs for single photon detection in such a Cherenkov imaging application.
Noise and radiation damage in silicon photomultipliers exposed to electromagnetic and hadronic radiation
2009
For the electron arm tracking system in the KAOS spectrometer at the Mainz Microtron MAMI a detector based on 2 m long scintillating fibres read out by silicon photomultipliers (SiPM) is planned. Because of the detector's close proximity to the intense electron beam a study of noise and radiation damage in SiPM has been performed. A sample of devices was exposed directly to a 14 MeV electron beam and to a mixed radiation field in the experimental area. First noticeable effects are a large increase in the dark count rate and a severe loss of the gain uniformity.
In-beam tests of scintillating fibre detectors at MAMI and at GSI
2008
The performance of scintillating fibre detectors was studied with electrons at the spectrometer facility of the Mainz microtron MAMI, as well as in a C-12 beam of 2 AGeV energy and in a beam of different particle species at GSI. Multi-anode photomultipliers were used to read out one or more bundles of 128 fibres each in different geometries. For electrons a time resolution of FWHM = 1 ns was measured in a single detector plane with a detection efficiency epsilon > 99%. A time resolution of 310 ps (FWHM) between two planes of fibres was achieved for carbon ions, leading to a FWHM = 220 ps for a single detector. The hit position residual was measured with a width of FWHM = 0.27 mm. The var…
The atmospheric nightglow in the 300– wavelength
2002
Abstract The balloon-borne experiment, named BAckground BYpass (BABY) belongs to a wider program that has as its final goal the detection and study of high-energy cosmic rays from space (satellite, Space Station). An information of fundamental importance for this class of projects concerns the nighttime background light. The instrument designed to detect fluorescence photons is basically composed of two collimated photomultipliers: a single photon-counting PMT and a charge integration PMT. We briefly report the details of the design, operation and performance of the detector, which was designed and completely built at the IFCAI–CNR Institute in Palermo. Preliminary analysis and results of t…
A compact Time Projection Chamber for the Crystal Ball
2016
Abstract We report on a development of a compact Time Projection Chamber with triple Gas Electron Multiplier readout to replace the current tracking detector in the Crystal Ball/TAPS Experiment at the A2 Tagged Photon Facility at MAMI in Mainz, Germany. Challenges are the limitations in size and the absence of a longitudinal magnetic flied.