Search results for "permeation"

showing 10 items of 274 documents

Separation of pesticides, related compounds, polychlorobiphenyls and other pollutants into four groups by silica‐gel microcolumn chromatography (appl…

1991

Multi‐residue analyses of pesticides and related compounds generally require clean‐up procedures for the elimination of interfering substances. An analytical procedure for use in the recovery and determination of pesticides and other pollutants in water samples is described, in which the purification of the extracts is improved by the separation of pesticides into four groups. The separation of pesticides by silica‐gel microcolumn chromatography is explained in detail. Copyright © 1991 John Wiley & Sons, Ltd

Gel permeation chromatographyPollutantchemistry.chemical_compoundChromatographyColumn chromatographychemistrySilica gelEnvironmental chemistryPesticideWater pollutionSurface waterApplied Microbiology and BiotechnologySeparation process
researchProduct

1986

Gel permeation chromatographyPolymerizationMethacrylate copolymerLiquid crystalGroup (periodic table)ChemistryLiquid crystallineTacticityPolymer chemistryGlass transitionDie Makromolekulare Chemie, Rapid Communications
researchProduct

1967

Gel chromatography can be considered as a network-limited partition. This leads to the conclusion that it is impossible to find a generalizing relationship between the molecular weight and the elution volume using parameters depending only on the solute. The preparation of gels with different chemical structure is discussed and possible methods for the alteration of pore size are described. Investigations of the influence of the physical and chemical structure on separation and separation efficiency have shown that the elution volume depends to some extent on the chemical nature, but the separation efficiency is mainly a function of the physical structure. Die Gelchromatographie kann als ei…

Gel permeation chromatographyPore sizePhysical structureElutionChemistryAnalytical chemistryGeneral Materials ScienceAngewandte Makromolekulare Chemie
researchProduct

1989

Synthese a partir du dibromo-1,5 di t-butyl-3,7 naphtalene via un monomere bifonctionnel (action du butyllithium et du triisopropoxyborane)

Gel permeation chromatographyTert butylchemistry.chemical_compoundChemistryStereochemistryMoleculechemistry.chemical_elementSolubilityMedicinal chemistryOligomerCatalysisPalladiumDie Makromolekulare Chemie, Rapid Communications
researchProduct

Gelchromatographie, die möglichkeiten verschiedener trennmaterialien

1968

Zur Gelchromatographie lassen sich organische und anorganische Trennmaterialien verwenden. Das reprasentative hochvernetzte Styragel wird benutzt, um vergleichende Untersuchungen mit porosen und Stoffen auf der Basis von Silicium und Aluminium auszufuhren. Fur die Trennung sehr hochmolekularer Substanzen, die Gele groser Porenweite erfordern, sind die anorganischen Gele wegen ihrer hohen mechanischen Stabilitat besonders geeignet. Fur Substanzen mit niedrigem Molekulargewicht sind organische und anorganische Trennstoffe hafig etwa gleich gut verwendbar, so das man den Geltyp wahlen kann, der moglichst nur hydrodynamische und keine chemische Wechselwirkung mit der Substanz zeigt. Organic and…

Gel permeation chromatographychemistry.chemical_classificationChemistryMechanical stabilityPhysical separationPolymer chemistryGeneral Materials ScienceInorganic materialsPolymerLarge poreAngewandte Makromolekulare Chemie
researchProduct

The efficiency of gel permeation chromatography

2007

The resolution power of gel permeation chromatography (GPC) columns and their combinations is tested as a function of the pore sizes of the gels and as a function of the elution velocity. The efficiency of GPC is characterized by the ratio UG/UT, where UG is the experimental, and UT the theoretical, inhomogeneity. The latter quantity is obtained from absolute measurements of Mw, and Mn. The ratio passes through a minimum for a series of columns with increasing pore sizes. The minimum occurs at that column or column set which is best suited to resolving a given polymer. UG/UT for any column decreases with decreasing elution velocity. At a certain velocity UG/UT becomes 1. This velocity is us…

Gel permeation chromatographychemistry.chemical_classificationChromatographyResolution (mass spectrometry)Absolute measurementChemistryElutionAnalytical chemistryPolymerCompression (physics)Journal of Polymer Science Part C: Polymer Symposia
researchProduct

1982

Phase distribution chromatography (PDC) is demonstrated to be a powerful method for the correct determination of narrow molecular weight distributions. This is shown by comparing the molecular weight distributions (MWD) of polystyrenes obtained from PDC measurements with those obtained by Baker-Williams fractionation and by gel permeation chromatography. Four problems are formulated and analyzed which are closely connected with the calculation of the MWD from a measured PDC-elution curve at temperatures below the theta point of the system. Thus, the theory of PDC outlined previously is tested.

Gel permeation chromatographychemistry.chemical_classificationDistribution (mathematics)ChromatographyChemistryPhase (matter)Analytical chemistryhemic and immune systemsmacromolecular substancesFractionationPolymerhumanitiesDie Makromolekulare Chemie
researchProduct

Solution properties of polyelectrolytes. I. Exclusion chromatography of sodium polystyrene sulphonate in salt-free water as eluent

1987

The effect of concentration of sodium polystyrene sulphonate on the elution volume in exclusion chromatography has been investigated using salt-free water as eluent. A non-linear increase in the elution volume has been observed with increasing injected sample concentration. Concentration-dependent calibrations have been obtained which approach the universal calibration for uncharged polymers (dextrans) as polyelectrolyte concentration increases. The separation mechanisms are interpreted in terms of electrostatic and hydrodynamic interactions. A semi-empirical model is proposed to predict concentration effects of linear polyions in exclusion chromatography and good agreement has been found b…

Gel permeation chromatographychemistry.chemical_classificationViscosityColumn chromatographyChromatographyChemistryElutionSize-exclusion chromatographyGeneral EngineeringGeneral Materials SciencePolymerSodium polystyrene sulphonatePolyelectrolyteBritish Polymer Journal
researchProduct

Zur Gelpermeationschromatographie in organischen Lösungsmitteln

1965

Die Gelpermeationschromatographie hat sich vor allem mittels der Sephadexgele fur die Trennung polymerhomologer wasserloslicher Makromolekule als sehr erfolgreich erwiesen. Die Trennung nur in organischen Losungsmitteln loslicher Polymerer ist erst in jungster Zeit gelungen, wobei vernetzte Polystyrol-, Polymethacrylat- und Dextranderivatgele benutzt werden. Der Mechanismus dieses chromatographischen Prozesses wird untersucht. Ein Vergleich dieses Vorganges, bei dem das Polymere nur in einer Phase vorliegt, mit den klassischen Methoden, die mit Auftrennung in zwei Phasen arbeiten, wird durchgefuhrt. Insbesondere werden die Methoden der Dreiecks-Fallungsfraktionierung, der Kolonnentechnik mi…

Gel permeation chromatographychemistry.chemical_classificationchemistry.chemical_compoundChemistryElutionGeneral Chemical EngineeringPolymer chemistryDextran DerivativesPolymerPolystyreneFractionationGeneral expressionSephadex gelsBerichte der Bunsengesellschaft für physikalische Chemie
researchProduct

Gel permeation chromatography, calibration, and distributions of cellulose trinitrates

1967

Gel permeation chromatographychemistry.chemical_compoundChromatographyColumn chromatographychemistrySize-exclusion chromatographyGeneral EngineeringCalibrationThermoresponsive polymers in chromatographyCelluloseJournal of Polymer Science Part B: Polymer Letters
researchProduct