Search results for "permeation"
showing 10 items of 274 documents
Sample Preparation Improvement in Polycyclic Aromatic Hydrocarbons Determination in Olive Oils by Gel Permeation Chromatography and Liquid Chromatogr…
2005
Abstract The determination of 15 polycyclic aromatic hydrocarbons (PAHs) in olive oil samples has been improved in order to obtain a fast methodology with a low limit of detection through the combination of liquid–liquid extraction with acetonitrile and preparative gel permeation chromatography (GPC) prior to the injection of purified extracts into a C18 column. Acetonitrile–water was used as the mobile phase with a gradient from 50 to 95%, w/w, acetonitrile in 30 min. The oven temperature was maintained at 15°C, and fluorometric detection was made at a fixed excitation wavelength of 264 nm and variable, optimal emission wavelength for each analyte ranging from 352 nm for 11-H-benzo(b)fluor…
Renewable polyol obtained by microwave-assisted alcoholysis of epoxidized soybean oil: Preparation, thermal properties and relaxation process
2019
[EN] The soybean oil polyol (SOP) use as feedstock in the polyurethane industry has been recently emphasized due to its excellent resistance to hydrolysis, which is also applicable in coatings and thermal insulation. In this article, the SOP was obtained by a very fast microwave-assisted alcoholysis of epoxidized soybean oil (ESO). The preparation method, thermal properties, and relaxation process were evaluated. High yields as opening and consumption epoxy group and selectivity of 99.8 mol%, 985 mol%, and 71.2 mol% were obtained. Through titrations, nuclear magnetic resonance and gel permeation chromatography were identified parameters as 0.32 mg KOH.g(-1) acid number, 190 mg KOH.g(-1) hyd…
Enhancing effect of alpha-hydroxyacids on "in vitro" permeation across the human skin of compounds with different lipophilicity.
2005
The percutaneous penetration-enhancing effects of glycolic acid, lactic acid and sodium lauryl sulphate through the human epidermis was investigated using 5-fluorouracil as a hydrophilic model permeant and three compounds belonging to the phenylalcohols: 2-phenyl-ethanol, 4-phenyl-butanol and 5-phenyl-pentanol. The lipophilicity values of the compounds ranged from log Poct -0.95 to 2.89. The effect of the enhancer concentration was also studied. Skin pretreatment with aqueous solutions of the three enhancers did not increase the permeability coefficient of the most lipophilic compound (log Poct = 2.89). For the other compounds assayed, the increase in the permeability coefficients depended …
Transdermal nortriptyline hydrocloride patch formulated within a chitosan matrix intended to be used for smoking cessation.
2010
The aim of this study was to prepare and characterize both physically and biopharmaceutically, a nortriptyline hydrochloride (NTP-HCl) patch formulated in chitosan.16 g of each chitosan patch formulation (I, II and III, see Table 1 ) was poured onto rectangular glass plates (64 cm²) at a height of 1 mm and dried for 24 h at room temperature. In order to characterize the chitosan patches, polarized microscopy, in vitro skin permeation studies by passive diffusion and iontophoresis and rheological and bioadhesion studies were performed.Polarized microscopy revealed the absence of aggregates and crystal forms of NTP-HCl in all transdermal patches after 30 days of storage. The rheological behav…
In Vitro Percutaneous Penetration of Acyclovir from Solvent Systems and Carbopol 971-P Hydrogels: Influence of Propylene Glycol
2005
The mechanism underlying propylene glycol (PG) effects on acyclovir (ACV) penetration through human epidermis were studied. Solvent systems and Carbopol gels containing increasing percentage of PG (from 0% to 70%, w/w) were used. Viscosity studies of both vehicles were carried out to characterise the influence of rheological behaviour. In solvent systems skin permeation values of ACV increase as the concentration of PG increase yielding a maximum enhancement ratio (ER = 10) for 70% PG. The release rate of ACV from gels was determined. Higuchi's model was used to estimate the apparent diffusion coefficient of the drug. These values show a decrease as the content of PG in the vehicle increase…
Comparison of Three Techniques for Lipid Removal from Seal Blubber: Gel Permeation, Acid Treatment, and Dialysis with Semipermeable Membrane
2000
Abstract Harbor seal blubber samples were analyzed for PCDD/Fs and PCBs by splitting the initial extract into three aliquots and applying three different techniques for lipid removal (the first step of sample cleanup methodology for GC-HRMS analysis): gel permeation chromatography (GPC), sulfuric acid treatment, and dialysis through semipermeable membrane. Correlation coefficients of analyte concentrations obtained from three sets of replicate samples ranged from 0.965 to 0.994. In addition, a number of seal blubber samples were processed without pre-extraction using only the dialysis technique. The analyte concentrations in these samples correlated well with the analyte concentrations obta…
Preconcentration of aluminium by micellar-enhanced ultrafiltration
1993
Abstract Traces of aluminium were preconcentrated in water samples by forming a complex with lumogallion, and successfully accumulated in the micellar phase obtained from cationic or non-ionic surfactants and filtered through 10 000 molecular weight cut-off ultrafiltration membranes. Studies indicated that, at pH 5.9, with 1 X 10 −3 M lumogallion and 2 X 10 −2 M cetyltrimethylamonium bromide, quantitative retention of aluminium present at μg ml −1 concentration levels was achieved. A micellar-enhanced fluorimetric procedure was employed to analyse the permeate solutions, whereas nitrous oxide-acetylene flame atomic emission spectrometry was used to determine aluminium in the retentate. The …
Ultra high performance liquid chromatography-time-of-flight high resolution mass spectrometry in the analysis of hexabromocyclododecane diastereomers…
2014
An efficient ultra high performance liquid chromatography (UHPLC)-time-of-flight high resolution mass spectrometry (TOF-HRMS) method was elaborated for the determination of hexabromocyclododecane (HBCD) diastereomers in fish samples and compared against UHPLC-Orbitrap-HRMS and UHPLC-triple quadrupole (QqQ) tandem MS (MS/MS) techniques. The TOF-HRMS analyzer was operated at high resolution (>10000 full width at half maximum (FWHM)) with scanning the m/z range from 600 to 700, to achieve picogram quantitation limits. The effects of various operational parameters on the instrumental response were systematically investigated. Evaluation of the influence of sample clean-up procedure steps on sig…
Enhanced In Situ Availability of Aphanizomenon Flos-Aquae Constituents Entrapped in Buccal Films for the Treatment of Oxidative Stress-Related Oral D…
2019
In recent years, the key role of oxidative stress in pathogenesis of oral diseases has been emphasized and the use of antioxidant agents has been encouraged. Aphanizomenon flos-aquae (AFA) is a unicellular blue-green alga with antioxidant and anti-inflammatory properties. The aim of this study was the formulation and characterization of mucoadhesive thin layer films loaded with AFA, finalized to the treatment of oxidative stress (OS)-related oral diseases. First, to enhance the bioavailability of AFA constituents, the raw food grade material was appropriately treated by a high frequency homogenization able to disrupt cell walls. Thus, Eudragit®
Modified nonsink equation for permeability estimation in cell monolayers: comparison with standard methods.
2014
Cell culture permeability experiments are valuable tools in drug development and candidate selection, but the monolayer preparation protocols and the calculations procedures can affect the permeability estimation. Hence, standardization and method suitability demonstration are necessary steps for using permeability data for regulatory and in vivo prediction purposes. Much attention is usually paid to experimental procedure validation and less to the mathematical analysis of the results although the standard equations used imply several assumptions that many times do not hold. The aim of this study was to use a simulation strategy to explore the performance of a new proposed modified nonsink…