Search results for "petrology"
showing 10 items of 1516 documents
Electrochemical discrimination of manufacturing types of pottery from Magna Mater Temple and Fora of Nerva and Caesar (Rome, Italy)
2018
Abstract The voltammetry of immobilized microparticles (VIMP) methodology is applied to a series of pottery samples from the Roman sites of Nerva's Forum (second half of 9th-early 11th A.D), Caesar's Forum (second half of 9th-early 11th A.D) and Magna Mater Temple (III century). The VIMP sampling applied to voltammetric and electrochemical impedance spectroscopy (EIS) measurements was applied by the first time to acquire archaeometric information on archaeological pottery. VIMP measurements using pressed sample pellets on gold electrodes in contact with air-saturated 0.10 M H2SO4 have permitted to detect voltammetric signals for the reduction/oxidation of Fe and Mn minerals as well as catal…
One-pot synthesis of ZnO nanoparticles supported on halloysite nanotubes for catalytic applications
2020
Abstract A versatile catalyst based on halloysite and zinc oxide (HNT@ZnO) was prepared, for the first time, starting from ZnO commercial bulk form as Zn precursor source, in a one-pot procedure. This strategy gives the possibility to obtain small ZnO nanoparticles loaded on the HNT surface without the use of inorganic salts which envisage the removal of undesired anions and therefore a calcination process at high temperature. It was found that the presence of halloysite improved the UV–vis spectral absorption ability of ZnO. The hybrid was successful used as photocatalyst for the methylorange and rhodamine B degradation. In addition, after eight consecutive cycles for the methylorange phot…
The Shielding Effect of Drilling Fluids on Measurement While Drilling Tool Downhole Compasses—The Effect of Drilling Fluid Composition, Contaminants,…
2016
Materials such as added clays, weight materials, drill solids, and metallic wear products in the drilling fluid are known to distort the geomagnetic field at the location of the measurement while drilling (MWD) tool magnetometers that are used to measure the direction of well path. This distortion contributes to substantial errors in determination of azimuth while drilling deviated wells. These errors may result in missing the target of a long deviated 12 ¼ in. section in the range of 1–200 m, representing a significant cost to be mitigated. The error becomes even more pronounced if drilling occurs in arctic regions close to the magnetic north pole (or south pole). The effect on the magneto…
Effects of irradiation damage on the back-scattering of electrons: silicon-implanted silicon
2007
Radiation damage in an (initially crystalline) silicon wafer was generated by microbeam implantation with 600 keV Si+ ions (fluence 5 x 1014 ions/cm²). To produce micro-areas with different degrees of damage, 14 implantations at different temperatures (between 23 and 225 °C) were done. The structural state of irradiated areas was characterized using Raman spectroscopy and electron back-scatter diffraction. All irradiated areas showed strong structural damage in surficial regions (estimated depth <1 μm), and at implant substrate temperatures of below 130 °C, the treatment has caused complete amorphization. Back-scattered electron (BSE) images exhibited that observed BSE intensities correlate…
Humidity effects on gravitational settling and Brownian diffusion of atmospheric aerosol particles
1977
The dependency on relative humidity of the settling velocity of aerosol particles in stagnant air and of the diffusion coefficient due to Brownian motion of aerosol particles was computed for six aerosol types and different particles sizes in dry state. The computations are based (1) on mean bulk densities of dry aerosol particles obtained from measurements or from the knowledge of the chemical composition of the particles, (2) on micro-balance measurements of the water uptake per unit mass of dry aerosol substance versus water activity at thermodynamic equilibrium, and (3) on measurements of the equilibrium water activity of aqueous sea salt solutions. The results show a significant depend…
Optical studies of Y3(Al,Ga)5O12:Ce3+,Cr3+,Nd3+ nano-phosphors obtained by the Pechini method
2019
The Y-3(Al,Ga)(5)O-12:Ce3+,Cr3+,Nd3+ (YAGG) nano-phosphors with homogeneous particle-size distribution, low aggregation and average crystalline size of about 65 nm were obtained using a modified Pechini method. Only slight aggregation of the crystallites occurs after post-annealing at 1100 degrees C. The intense Ce3+ bands in the excitation spectra of the Ce3+,Cr3+,Nd3+ co-doped materials monitoring the Cr3+ emission at 690 nm indicate energy transfer from Ce(3+ )to Cr3+. Weak Nd3+ lines are observed, as well. In addition, the emission of Nd3+ at 1060 nm with excitation of Ce3+ and Cr3+ confirms the Ce3+/Cr3+ to Nd3+ energy transfer. The short average luminescence decay times for the Ce3+ e…
Simulating permeability reduction by clay mineral nanopores in a tight sandstone by combining computer X-ray microtomography and focussed ion beam sc…
2021
Solid earth 12(1), 1 - 14 (2021). doi:10.5194/se-12-1-2021
2020
Abstract. Residual pressure can be preserved in mineral inclusions, e.g. quartz-in-garnet, after exhumation due to differential expansion between inclusion and host crystals. Raman spectroscopy has been applied to infer the residual pressure and provides information on the entrapment temperature and pressure conditions. However, the amount of residual pressure relaxation cannot be directly measured. An underestimation or overestimation of residual pressure may lead to significant errors between calculated and actual entrapment pressure. This study focuses on three mechanisms responsible for the residual pressure modification: (1) viscous creep; (2) plastic yield; (3) proximity of inclusion …
Characterisation of Apatites as Potential Uranium Reference Materials for Fission-track Dating by LA-ICP-MS
2015
We report homogeneity tests on large natural apatite crystals to evaluate their potential as U reference materials for apatite fission-track (AFT) thermochronology by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). The homogeneity tests include the measurements of major element concentrations by electron probe microanalysis (EPMA), whereas for U concentration, isotope dilution (ID) ICP-MS and laser ablation (LA) ICP-MS were employed. Two apatite crystals are potential reference materials for LA-ICP-MS analysis: a 1 cm3 fraction of a Durango crystal (7.5 μg g−1 U) and a 1 cm3 Mud Tank crystal (6.9 μg g−1 U). The relative standard deviation (1 RSD) of the U concentrat…
High-pressure crystal structure investigation of synthetic Fe2SiO4 spinel.
2011
AbstractThe crystal structure of Fe2SiO4 spinel at room temperature was investigated at seven different pressures by X-ray diffraction, using a diamond anvil cell to examine the influence of Fe substitution on ringwoodite behaviour at high pressure. The results compared with those of a pure Mg endmember show that the substitution of Fe into the spinel structure causes only small changes in the compression rate of coordination polyhedra and the distortion of the octahedron. The data show that the compression rate for the octahedron and tetrahedron in (Mg,Fe)2SiO4 can be considered statistically equal for FeO6 and MgO6, as well as for SiO4 in both the endmembers. This shows why almost identic…