Search results for "phantom"

showing 10 items of 196 documents

Robust three-dimensional best-path phase-unwrapping algorithm that avoids singularity loops.

2009

In this paper we propose a novel hybrid three-dimensional phase-unwrapping algorithm, which we refer to here as the three-dimensional best-path avoiding singularity loops (3DBPASL) algorithm. This algorithm combines the advantages and avoids the drawbacks of two well-known 3D phase-unwrapping algorithms, namely, the 3D phase-unwrapping noise-immune technique and the 3D phase-unwrapping best-path technique. The hybrid technique presented here is more robust than its predecessors since it not only follows a discrete unwrapping path depending on a 3D quality map, but it also avoids any singularity loops that may occur in the unwrapping path. Simulation and experimental results have shown that …

Synthetic aperture radarOptics and PhotonicsTime FactorsComputer scienceMaterials Science (miscellaneous)Physics::Medical PhysicsIndustrial and Manufacturing EngineeringGeneralLiterature_MISCELLANEOUSQA76Pattern Recognition AutomatedQuantitative Biology::Subcellular ProcessesSingularityRobustness (computer science)Artificial IntelligenceImage Interpretation Computer-AssistedComputer SimulationBusiness and International ManagementQAQuantitative Biology::BiomoleculesT1Phantoms ImagingModels TheoreticalPhase unwrappingMagnetic Resonance ImagingProgramming LanguagesPhase retrievalAlgorithmAlgorithmsSoftwareApplied optics
researchProduct

Introduction to coronary imaging with 64-slice computed tomography

2005

The aim of this article is to illustrate the main technical improvements in the last generation of 64-row CT scanners and the possible applications in coronary angiography. In particular, we describe the new physical components (X-ray tube-detectors system) and the general scan and reconstruction parameters. We then define the scan protocols for coronary angiography with the new generation of 64-row CT scanners to enable radiologists to perform a CT study on the basis of the diagnostic possibilities.

Time FactorsImaging Sensitivity and Specificity Stents Time Factors TomographyContrast MediaSensitivity and Specificity64-row CTElectrocardiographyHeart RateSpiral Computed TomographyImage Processing Computer-AssistedHumanstechnical improvementsCoronary Artery BypassPhantoms ImagingPatient SelectionAlgorithms Artifacts Contrast Media Coronary Angiography/instrumentation/*methods Coronary Artery Bypass Coronary Stenosis/*radiography Electrocardiography Heart Rate Humans Image Processing; Computer-Assisted Patient Selection Phantoms; Imaging Sensitivity and Specificity Stents Time Factors Tomography; Spiral Computed Tomography; X-Ray Computed/instrumentation/*methodsCoronary StenosisComputer-Assisted Patient Selection PhantomsX-Ray Computed/instrumentation/*methodstechnical improvements; 64-row CT; coronary angiographyComputer-Assisted Patient Selection PhantomStentsAlgorithms Artifacts Contrast Media Coronary Angiography/instrumentation/*methods Coronary Artery Bypass Coronary Stenosis/*radiography Electrocardiography Heart Rate Humans Image Processingcoronary angiographyArtifactsTomography X-Ray ComputedTomography Spiral ComputedAlgorithms
researchProduct

Comparison of basis functions for 3D PET reconstruction using a Monte Carlo system matrix.

2012

In emission tomography, iterative statistical methods are accepted as the reconstruction algorithms that achieve the best image quality. The accuracy of these methods relies partly on the quality of the system response matrix (SRM) that characterizes the scanner. The more physical phenomena included in the SRM, the higher the SRM quality, and therefore higher image quality is obtained from the reconstruction process. High-resolution small animal scanners contain as many as 103?104 small crystal pairs, while the field of view (FOV) is divided into hundreds of thousands of small voxels. These two characteristics have a significant impact on the number of elements to be calculated in the SRM. …

Time FactorsRadiological and Ultrasound TechnologyRotationStatistical noisebusiness.industryImage qualityPhantoms ImagingMonte Carlo methodBasis functioncomputer.software_genreNoiseImaging Three-DimensionalVoxelPositron-Emission TomographyRadiology Nuclear Medicine and imagingComputer visionArtificial intelligencebusinesscomputerAlgorithmImage resolutionMonte Carlo MethodSmoothingMathematicsPhysics in medicine and biology
researchProduct

A free plate model can predict guided modes propagating in tubular bone-mimicking phantoms

2014

The goal of this work was to show that a non-absorbing free plate model can predict with a reasonable accuracy guided modes measured in bone-mimicking phantoms that have circular cross-section. Experiments were carried out on uncoated and coated phantoms using a clinical axial transmission setup. Adjustment of the plate model to the experimental data yielded estimates for the waveguide characteristics (thickness, bulk wave velocities). Fair agreement was achieved over a frequency range of 0.4 to 1.6 MHz. A lower accuracy observed for the thinnest bone-mimicking phantoms was caused by limitations in the wave number measurements rather than by the model itself.

Tubular boneGlycerolguided modeswaveguide characteristicWork (thermodynamics)Materials scienceAcoustics and UltrasonicsBioacousticsAcousticsTransducersBone and Boneslaw.inventionOpticsArts and Humanities (miscellaneous)lawBone DensityAluminum OxideHumansfrequency rangesAluminum oxideAxial transmissionta217ta114circular cross-sectionsbusiness.industryEpoxy ResinsPhantoms Imagingreasonable accuracyEquipment DesignModels Theoreticalequipment and suppliesplate modelJasa Express LettersTransducerSoundaxial transmissionSilicone ElastomersElasticity Imaging TechniquesOsteoporosisUltrasonic propagationbusinesswave numbersWaveguideJournal of the Acoustical Society of America
researchProduct

Comparison of Flow Measurement by 4D Flow Magnetic Resonance Imaging and by Particles Image Velocimetry on Phantom of Abdominal Aortic Aneurysm

2016

International audience; Predicting the rupture of Aortic Aneurysms is a complex problem that interests, from several decades, many researchers. The works on this issue are very complex, involving both the study of mechanical behavior of the artery as the flow of blood. The Magnetic Resonance Imaging (MRI) technique allows to obtain anatomic information of the arteries, than the flow inside thereof. The goal of this study is an inter comparison betweenflow data from MRI and those obtained by Particle Image Velocimetry (PIV). An experimental device simulating hemodynamic circulation is used. Initially in order to validate the device, the flow in a cylindrical glass tube is measured by these t…

[ SPI.MECA.GEME ] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]PIVFluid velocity measurementMetrology in medical Imaging[SPI.MECA.GEME] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]Aorta phantomAbdominal Aorta Aneurysm[SPI.MECA.GEME]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Mechanical engineering [physics.class-ph]MRI
researchProduct

Design and development of a fNIRS system prototype based on SiPM detectors

2014

Functional Near Infrared Spectroscopy (fNIRS) uses near infrared sources and detectors to measure changes in absorption due to neurovascular dynamics in response to brain activation. The use of Silicon Photomultipliers (SiPMs) in a fNIRS system has been estimated potentially able to increase the spatial resolution. Dedicated SiPM sensors have been designed and fabricated by using an optimized process. Electrical and optical characterizations are presented. The design and implementation of a portable fNIRS embedded system, hosting up to 64 IR-LED sources and 128 SiPM sensors, has been carried out. The system has been based on a scalable architecture whose elementary leaf is a flexible board …

business.industryComputer scienceDetectorNear-infrared spectroscopySettore ING-INF/02 - Campi ElettromagneticiNear Infrared SpectroscopySilicon PhotomultipliersReflectivitySettore ING-INF/01 - ElettronicaImaging phantomlaw.inventionOpticsSilicon photomultiplierlawOptoelectronicsSensitivity (control systems)businessEmbedded SystemsImage resolutionSilicon PhotomultiplierLight-emitting diode
researchProduct

Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma

2013

Purpose : The aim of this study was to obtain equivalent doses in radiosensitive organs (aside from the bladder and rectum) when applying high-dose-rate (HDR) brachytherapy to a localized prostate carcinoma using60Co or 192 Ir sources. These data are compared with results in a water phantom and with expected values in an infinite water medium. A comparison with reported values from proton therapy and intensity-modulated radiation therapy (IMRT) is also provided. Methods : Monte Carlo simulations in Geant4 were performed using a voxelized phantom described in International Commission on Radiological Protection (ICRP) Publication 110, which reproduces masses and shapes from an adult reference…

business.industryEquivalent dosemedicine.medical_treatmentBrachytherapyGeneral MedicineEffective dose (radiation)Imaging phantomRadiation therapyAbsorbed doseMedicineDosimetrybusinessNuclear medicineProton therapyMedical Physics
researchProduct

Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source.

2011

Purpose: Recently, a new HDR 60 Co brachytherapy source, Flexisource Co-60, has been developed (Nucletron B.V. Veenendaal, The Netherlands). This study aims to obtain dosimetric data for this source for its use in clinical practice as required by AAPM and ESTRO. Material and methods: Two Monte Carlo radiation transport codes were used: Penelope2008 and GEANT4. The source was centrally-positioned in a 100 cm radius water phantom. Absorbed dose and collisional kerma were obtained using 0.01 cm (close) and 0.1 cm (far) sized voxels to provide high-resolution dosimetry near (far from) the source. Dose rate distributions obtained with the two Monte Carlo codes were compared. Results and Discussi…

business.industryFlexisource Co-60Penelope2008medicine.medical_treatmentBrachytherapyMonte Carlo methodbrachytherapyImaging phantomComputational physicsKermaOncologyAbsorbed doseMedicineDosimetryRadiology Nuclear Medicine and imagingOriginal ArticlebusinessDose rateRadiation treatment planningNuclear medicineTG-43GEANT4Journal of contemporary brachytherapy
researchProduct

TH-C-AUD A-07: Evaluation of the Correction Factor Due to the Lack of Full Scatter Conditions in Cs-137 and Ir-192 Brachytherapy Dosimetric Studies

2008

Purpose: Use of a finite phantom to derive dose rate distributions around brachytherapysources implies a lack of backscattering material near the phantom periphery. Conventional planning algorithms and newly‐developed 3D correction algorithms are based on physics data under full scatter conditions. Presently, most published Monte Carlodosimetric studies have been obtained using either a spherical phantom (15cm in radius) or a cylinder phantom (40×40cm2). The study objective was to derive a simple relationship to correlate the radial dose function, g(r), obtained for each one of these phantoms to that obtained for an unbounded phantom. Method and Materials: Assuming bare point sources of 137…

business.industryMonte Carlo methodGeneral MedicineRadiusImaging phantomComputational physicsKermaOpticsConsistency (statistics)Bounded functionDosimetryCylinderbusinessMathematicsMedical Physics
researchProduct

Re-exposure in cone beam CT of the dentomaxillofacial region: a retrospective study.

2018

Cone beam CT (CBCT) often uses a smaller field of view compared to conventional CT scans. This might lead to a wrong field of view with the need for secondary exposure (“retakes”). The purpose of this retrospective study was to assess the frequency of re-exposures in CBCT and to identify whether the parameters age, gender, and field of view have an influence on the re-exposure of the patient. Additionally, the causes of re-exposures were determined and categorized. METHODS: In a retrospective cohort study CBCT images of 4986 patients from the patient database from the Department of Oral Radiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany were included a…

business.industryPhantoms ImagingField of viewRetrospective cohort study030206 dentistryGeneral MedicineCone-Beam Computed Tomographyequipment and supplies030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOtorhinolaryngologystomatognathic systemRadiography DentalMedicineHumansRadiology Nuclear Medicine and imagingbusinessNuclear medicineArtifactsGeneral DentistryCone beam ctRetrospective StudiesResearch ArticleDento maxillo facial radiology