Search results for "phantom"
showing 10 items of 196 documents
Phantom Limb Pain in Daily Practice—Still a Lot of Work to Do!
2012
Objectives. Effective treatment of phantom limb pain (PLP, pain felt in the part of the body of an amputated limb) is still difficult to achieve, and improved treatment is needed. It is therefore of paramount interest to understand the current practice of PLP therapy outside pain centers. Design. As a part of a nationwide survey, 537 amputees were asked 11 questions related to their treatment experiences and the pain relief. Furthermore, the patients' opinion about the quality of medical care was also asked. Results. Five hundred thirty-seven out of 1088 amputees returned the questionnaire (49.4%). Four hundred (74.5%) suffered from PLP. The patients rated their caregivers' knowledge about …
Efficacy of single-source rapid kV-switching dual-energy CT for characterization of non-uric acid renal stones: a prospective ex vivo study using ant…
2019
Purpose To investigate the accuracy of rapid kV-switching single-source dual-energy computed tomography (rsDECT) for prediction of classes of non-uric-acid stones. Materials and methods Non-uric-acid renal stones retrieved via percutaneous nephrolithotomy were prospectively collected between January 2017 and February 2018 in a single institution. Only stones >= 5 mm and with pure composition (i.e., >= 80% composed of one component) were included. Stone composition was determined using Fourier Transform Infrared Spectroscopy. The stones were scanned in 32-cm-wide anthropomorphic whole-body phantom using rsDECT. The effective atomic number (Zeff), the attenuation at 40 keV (HU40), 70 ke…
Diffusion-tensor MR imaging at 1.5 and 3.0 T: initial observations.
2001
Diffusion-tensor MR imaging was compared at 1.5 and 3.0 T. With sufficient signal-to-noise ratio, we found no differences in fractional anisotropy. With a 40% higher signal-to-noise ratio at 3.0 T, higher resolution could be obtained without introduction of noise-related errors, albeit at the cost of increased geometric distortions caused by 3.0-T magnetic field inhomogeneities.
Quantitative analysis of emphysema in 3D using MDCT: Influence of different reconstruction algorithms
2008
Abstract Purpose The aim of the study was to compare the influence of different reconstruction algorithms on quantitative emphysema analysis in patients with severe emphysema. Material and methods Twenty-five patients suffering from severe emphysema were included in the study. All patients underwent inspiratory MDCT (Aquilion-16, slice thickness 1/0.8 mm). The raw data were reconstructed using six different algorithms: bone kernel with beam hardening correction (BHC), soft tissue kernel with BHC; standard soft tissue kernel, smooth soft tissue kernel (internal reference standard), standard lung kernel, and high-convolution kernel. The only difference between image data sets was the algorith…
Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques
2008
Purpose To compare three different autocalibrated parallel acquisition techniques (PAT) for quantitative and semiquantitative myocardial perfusion imaging. Materials and Methods Seven healthy volunteers underwent myocardial first-pass perfusion imaging at rest using an SR-TrueFISP pulse sequence without PAT and while using GRAPPA, mSENSE, and TSENSE. signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), normalized upslopes (NUS), and myocardial blood flow (MBF) were calculated. Artifacts, image noise, and overall image quality were qualitatively assessed. Furthermore, the relation between signal intensity (SI) and contrast medium (CM) concentration was determined in phantoms. Results …
A simplified framework to optimize MRI contrast preparation
2018
PURPOSE This article proposes a rigorous optimal control framework for the design of preparation schemes that optimize MRI contrast based on relaxation time differences. METHODS Compared to previous optimal contrast preparation schemes, a drastic reduction of the optimization parameter number is performed. The preparation scheme is defined as a combination of several block pulses whose flip angles, phase terms and inter-pulse delays are optimized to control the magnetization evolution. RESULTS The proposed approach reduces the computation time of B 0 -robust preparation schemes to around a minute (whereas several hours were required with previous schemes), with negligible performance loss. …
ALANINE/ESR DOSIMETRY FOR TOTAL BODY IRRADIATION USING AN ANTHROPOMORPHIC PHANTOM
2016
Introduction: Total Body Irradiation (TBI) is a technique widely used in the radiation blood-oncology in the treatment of patients that need bone marrow transplantation or peripheral stem cell transplantation. This technique has some limitations such as the lack of homogeneity of the dose distribution (which may show variations of 20% in the different areas), irradiation of critical organs such as the lungs, the liver, the intestine and the eye-lens which can receive a dose comparable to that nominal and require appropriate shielding and a proper evaluation of the dose absorbed by them. The positive outcome of this type of radiation therapy is strictly related to a precise and accurate meas…
An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.
2015
Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…
Focused Ultrasound Effects on Osteosarcoma Cell Lines
2019
MRI guided Focused Ultrasound (MRgFUS) has shown to be effective therapeutic modality for non-invasive clinical interventions in ablating of uterine fibroids, in bone metastasis palliative treatments, and in breast, liver, and prostate cancer ablation. MRgFUS combines high intensity focused ultrasound (HIFU) with MRI images for treatment planning and real time thermometry monitoring, thus enabling non-invasive ablation of tumor tissue. Although in the literature there are several studies on the Ultrasound (US) effects on cell in culture, there is no systematic evidence of the biological effect of Magnetic Resonance guided Focused Ultrasound Surgery (MRgFUS) treatment on osteosarcoma cells, …
Abstract ID: 133 Fast and accurate 3D dose distribution computations using artificial neural networks
2017
In radiation therapy, the trade-off between accuracy and speed is the key of the algorithms used in Treatment Planning Systems (TPS). For photon beams, commercial solutions generally relies on analytic algorithms, biased Monte Carlo, or heavily parallelized Monte Carlo on Graphics Processing Units (GPU). Alternatively, we propose an algorithm using Artificial Neural Network (ANN) to compute the dose distributions resulting from ionizing radiations inside a phantom [1] , [2] . We present an evolution of this platform taking into account modulated field sizes and shapes, and various orientations of the beam to the phantom. Firstly, tomodensitometry-based phantoms are created to validate the d…