Search results for "phantom"

showing 10 items of 196 documents

Phantom Limb Pain in Daily Practice—Still a Lot of Work to Do!

2012

Objectives. Effective treatment of phantom limb pain (PLP, pain felt in the part of the body of an amputated limb) is still difficult to achieve, and improved treatment is needed. It is therefore of paramount interest to understand the current practice of PLP therapy outside pain centers. Design. As a part of a nationwide survey, 537 amputees were asked 11 questions related to their treatment experiences and the pain relief. Furthermore, the patients' opinion about the quality of medical care was also asked. Results. Five hundred thirty-seven out of 1088 amputees returned the questionnaire (49.4%). Four hundred (74.5%) suffered from PLP. The patients rated their caregivers' knowledge about …

AdultMaleReoperationHealth Knowledge Attitudes Practicemedicine.medical_specialtymedicine.medical_treatmentPhantom limbchemical and pharmacologic phenomenaRelaxation TherapyPhantom limb painAmputeesimmune system diseasesGermanySurveys and QuestionnairesDaily practicemedicineHumansPain ManagementEffective treatmentQuality of Health Carebusiness.industryAmputation StumpsGeneral MedicineMiddle Agedmedicine.diseaseNeuromanervous system diseasesAnalgesics OpioidTreatment OutcomeAnesthesiology and Pain MedicinePain ClinicsPhantom LimbAmputationOpioidPatient SatisfactionTranscutaneous Electric Nerve StimulationPhysical therapyAnticonvulsantsFemalelipids (amino acids peptides and proteins)Clinical CompetenceNeurology (clinical)businessmedicine.drugPain Medicine
researchProduct

Efficacy of single-source rapid kV-switching dual-energy CT for characterization of non-uric acid renal stones: a prospective ex vivo study using ant…

2019

Purpose To investigate the accuracy of rapid kV-switching single-source dual-energy computed tomography (rsDECT) for prediction of classes of non-uric-acid stones. Materials and methods Non-uric-acid renal stones retrieved via percutaneous nephrolithotomy were prospectively collected between January 2017 and February 2018 in a single institution. Only stones >= 5 mm and with pure composition (i.e., >= 80% composed of one component) were included. Stone composition was determined using Fourier Transform Infrared Spectroscopy. The stones were scanned in 32-cm-wide anthropomorphic whole-body phantom using rsDECT. The effective atomic number (Zeff), the attenuation at 40 keV (HU40), 70 ke…

AdultMaleUrologymedicine.medical_treatmentStone compositionNephrolithotomy PercutaneousImaging phantom030218 nuclear medicine & medical imagingRapid kVp switchingRadiography Dual-Energy Scanned Projection03 medical and health scienceschemistry.chemical_compoundSingle-source0302 clinical medicineSpectroscopy Fourier Transform InfraredmedicineHumansUrolithiasiRadiology Nuclear Medicine and imagingProspective StudiesStone compositionKidney stonePercutaneous nephrolithotomyAgedRadiological and Ultrasound TechnologyPhantoms Imagingbusiness.industryGastroenterologyMiddle Agedmedicine.diseaseDual-energy CTchemistry030220 oncology & carcinogenesisMann–Whitney U testRadiographic Image Interpretation Computer-AssistedUric acidFemaleUrinary CalculiKidney stonesDual energy ctTomography X-Ray ComputedNuclear medicinebusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaEffective atomic number
researchProduct

Diffusion-tensor MR imaging at 1.5 and 3.0 T: initial observations.

2001

Diffusion-tensor MR imaging was compared at 1.5 and 3.0 T. With sufficient signal-to-noise ratio, we found no differences in fractional anisotropy. With a 40% higher signal-to-noise ratio at 3.0 T, higher resolution could be obtained without introduction of noise-related errors, albeit at the cost of increased geometric distortions caused by 3.0-T magnetic field inhomogeneities.

AdultMalebusiness.industryPhantoms ImagingResolution (electron density)BrainMagnetic Resonance ImagingMagnetic fieldNuclear magnetic resonanceSignal-to-noise ratio (imaging)Fractional anisotropySpin echoMedicineHumansRadiology Nuclear Medicine and imagingFemaleTensorDiffusion (business)businessDiffusion MRIRadiology
researchProduct

Quantitative analysis of emphysema in 3D using MDCT: Influence of different reconstruction algorithms

2008

Abstract Purpose The aim of the study was to compare the influence of different reconstruction algorithms on quantitative emphysema analysis in patients with severe emphysema. Material and methods Twenty-five patients suffering from severe emphysema were included in the study. All patients underwent inspiratory MDCT (Aquilion-16, slice thickness 1/0.8 mm). The raw data were reconstructed using six different algorithms: bone kernel with beam hardening correction (BHC), soft tissue kernel with BHC; standard soft tissue kernel, smooth soft tissue kernel (internal reference standard), standard lung kernel, and high-convolution kernel. The only difference between image data sets was the algorith…

AdultMalegenetic structuresinformation scienceAbsolute differenceStatistics NonparametricPulmonary function testingImaging Three-DimensionalHumansMedicinenatural sciencesRadiology Nuclear Medicine and imagingLung volumesAgedPhantoms Imagingbusiness.industryfood and beveragesSoft tissueReconstruction algorithmGeneral MedicineMiddle AgedRespiratory Function TestsPulmonary EmphysemaKernel (statistics)Radiographic Image Interpretation Computer-AssistedFemaleTomographyTomography X-Ray ComputedbusinessNuclear medicineAlgorithmQuantitative analysis (chemistry)AlgorithmsSoftwareEuropean Journal of Radiology
researchProduct

Quantitative myocardial perfusion imaging using different autocalibrated parallel acquisition techniques

2008

Purpose To compare three different autocalibrated parallel acquisition techniques (PAT) for quantitative and semiquantitative myocardial perfusion imaging. Materials and Methods Seven healthy volunteers underwent myocardial first-pass perfusion imaging at rest using an SR-TrueFISP pulse sequence without PAT and while using GRAPPA, mSENSE, and TSENSE. signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), normalized upslopes (NUS), and myocardial blood flow (MBF) were calculated. Artifacts, image noise, and overall image quality were qualitatively assessed. Furthermore, the relation between signal intensity (SI) and contrast medium (CM) concentration was determined in phantoms. Results …

AdultMalemedicine.diagnostic_testPhantoms Imagingbusiness.industryImage qualityPerfusion scanningPulse sequenceBlood flowMagnetic Resonance ImagingMyocardial perfusion imagingContrast mediumCoronary CirculationHealthy volunteerscardiovascular systemmedicineImage noiseHumansFemaleRadiology Nuclear Medicine and imagingNuclear medicinebusinessMathematicsJournal of Magnetic Resonance Imaging
researchProduct

A simplified framework to optimize MRI contrast preparation

2018

PURPOSE This article proposes a rigorous optimal control framework for the design of preparation schemes that optimize MRI contrast based on relaxation time differences. METHODS Compared to previous optimal contrast preparation schemes, a drastic reduction of the optimization parameter number is performed. The preparation scheme is defined as a combination of several block pulses whose flip angles, phase terms and inter-pulse delays are optimized to control the magnetization evolution. RESULTS The proposed approach reduces the computation time of B 0 -robust preparation schemes to around a minute (whereas several hours were required with previous schemes), with negligible performance loss. …

AgingMultiple Sclerosis[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/ImagingComputer scienceComputationContrast MediaContext (language use)HippocampusCorpus Callosum030218 nuclear medicine & medical imagingReduction (complexity)Magnetics03 medical and health sciences0302 clinical medicineThalamusAlzheimer Disease[INFO.INFO-IM]Computer Science [cs]/Medical ImagingAnimalsHumansComputer SimulationRadiology Nuclear Medicine and imagingPoint (geometry)Gray MatterComputingMilieux_MISCELLANEOUSBlock (data storage)Flexibility (engineering)Phantoms ImagingBrainContrast (statistics)Models TheoreticalOptimal controlMagnetic Resonance ImagingRatsFemaleAlgorithmAlgorithms030217 neurology & neurosurgeryMagnetic Resonance in Medicine
researchProduct

ALANINE/ESR DOSIMETRY FOR TOTAL BODY IRRADIATION USING AN ANTHROPOMORPHIC PHANTOM

2016

Introduction: Total Body Irradiation (TBI) is a technique widely used in the radiation blood-oncology in the treatment of patients that need bone marrow transplantation or peripheral stem cell transplantation. This technique has some limitations such as the lack of homogeneity of the dose distribution (which may show variations of 20% in the different areas), irradiation of critical organs such as the lungs, the liver, the intestine and the eye-lens which can receive a dose comparable to that nominal and require appropriate shielding and a proper evaluation of the dose absorbed by them. The positive outcome of this type of radiation therapy is strictly related to a precise and accurate meas…

AlanineMaterials sciencebusiness.industrySettore FIS/01 - Fisica SperimentaleBiophysicsGeneral Physics and AstronomyGeneral MedicineTotal body irradiationSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Esr dosimetryNuclear magnetic resonanceRadiology Nuclear Medicine and imagingAnthropomorphic phantomESR EPR Dosimetry TBINuclear medicinebusinessSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct

An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.

2015

Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…

Aortic archModels AnatomicRadiology Nuclear Medicine and ImagingTime FactorsFlow modelPulsatile flowEndograftStent-graft oversizingAorta Thoracic030204 cardiovascular system & hematologyRotation0302 clinical medicineForeign-Body MigrationStentThoracic aortaBird-beak configurationmedicine.diagnostic_testEndovascular ProceduresGraft Occlusion VascularModels CardiovascularAnatomyIn vitro experimentProsthesis FailureBlood Vessel ProsthesiTreatment OutcomePulsatile FlowPatient-specific modelStentsCardiology and Cardiovascular MedicineHumanAortographyTime FactorThoracic endovascular aortic repairProsthesis DesignAortographyImaging phantom03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesismedicine.arterymedicineHumansDisplacement (orthopedic surgery)HemodynamicEndovascular Procedurebusiness.industryHemodynamicsDisplacementStent-graft infoldingBlood Vessel ProsthesisSurgerybusinessTomography X-Ray Computed030217 neurology & neurosurgeryStent-graft collapseJournal of endovascular therapy : an official journal of the International Society of Endovascular Specialists
researchProduct

Focused Ultrasound Effects on Osteosarcoma Cell Lines

2019

MRI guided Focused Ultrasound (MRgFUS) has shown to be effective therapeutic modality for non-invasive clinical interventions in ablating of uterine fibroids, in bone metastasis palliative treatments, and in breast, liver, and prostate cancer ablation. MRgFUS combines high intensity focused ultrasound (HIFU) with MRI images for treatment planning and real time thermometry monitoring, thus enabling non-invasive ablation of tumor tissue. Although in the literature there are several studies on the Ultrasound (US) effects on cell in culture, there is no systematic evidence of the biological effect of Magnetic Resonance guided Focused Ultrasound Surgery (MRgFUS) treatment on osteosarcoma cells, …

Article SubjectUterine fibroidsSettore MED/06 - Oncologia MedicaCell Survivalmedicine.medical_treatmentlcsh:MedicineBone NeoplasmsThermometryBone NeoplasmGeneral Biochemistry Genetics and Molecular Biology030218 nuclear medicine & medical imaging03 medical and health sciencesProstate cancer0302 clinical medicineSettore BIO/13 - Biologia ApplicataOsteogenesisCell Line TumormedicineHumansOsteosarcomaGeneral Immunology and Microbiologymedicine.diagnostic_testbusiness.industryPhantoms ImagingOsteogenesiUltrasoundlcsh:RBone metastasisMagnetic resonance imagingGeneral Medicinemedicine.diseaseAblationMagnetic Resonance ImagingHigh-intensity focused ultrasound3. Good healthSurgery Computer-Assisted030220 oncology & carcinogenesisOsteosarcomaHigh-Intensity Focused Ultrasound AblationSettore MED/46 - Scienze Tecniche Di Medicina Di LaboratoriobusinessNuclear medicineSettore MED/36 - Diagnostica Per Immagini E RadioterapiaHumanResearch ArticleBioMed Research International
researchProduct

Abstract ID: 133 Fast and accurate 3D dose distribution computations using artificial neural networks

2017

In radiation therapy, the trade-off between accuracy and speed is the key of the algorithms used in Treatment Planning Systems (TPS). For photon beams, commercial solutions generally relies on analytic algorithms, biased Monte Carlo, or heavily parallelized Monte Carlo on Graphics Processing Units (GPU). Alternatively, we propose an algorithm using Artificial Neural Network (ANN) to compute the dose distributions resulting from ionizing radiations inside a phantom [1] , [2] . We present an evolution of this platform taking into account modulated field sizes and shapes, and various orientations of the beam to the phantom. Firstly, tomodensitometry-based phantoms are created to validate the d…

Artificial neural networkComputer scienceComputationPhysics::Medical PhysicsMonte Carlo methodBiophysicsGeneral Physics and AstronomyGeneral MedicineSquare (algebra)Imaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisRadiology Nuclear Medicine and imagingCentral processing unitGraphicsAlgorithmBeam (structure)Physica Medica
researchProduct