Search results for "phenomena"

showing 10 items of 8379 documents

Effects of pregnancy on lumbar motion patterns and muscle responses.

2018

The kinematics of the lumbar region and the activation patterns of the erector spinae muscle have been associated with the genesis of low back pain, which is one of the most common complications associated with pregnancy. Despite the high prevalence of pregnancy-related low back pain, the biomechanical adaptations of the lumbar region during pregnancy remain unknown.This study analyzes lumbar spine motion and the activation pattern of the lumbar erector spinae muscle in healthy pregnant women.A case-control study.The study involved 34 nulliparous women (control group) and 34 pregnant women in the third trimester (week 36 ± 1).We recorded the parameters of angular displacement of the lumbar …

musculoskeletal diseasesAdultmedicine.medical_specialtyLigamentous laxityMovementElectromyography03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationLumbarPregnancyErector spinae musclesMedicineEccentricHumansOrthopedics and Sports MedicineRange of Motion ArticularMuscle Skeletal030222 orthopedicsmedicine.diagnostic_testbusiness.industryLumbosacral Regionmedicine.diseaseLow back painTrunkSagittal planeBiomechanical Phenomenamedicine.anatomical_structureSurgeryFemaleNeurology (clinical)medicine.symptombusinessLow Back Pain030217 neurology & neurosurgeryThe spine journal : official journal of the North American Spine Society
researchProduct

Estimation of structural and geometrical properties of cortical bone by computerized tomography in 78-year-old women

2009

The structural and geometrical properties of the tibia shaft were investigated at two sections by means of computerized tomography (CT) in 78-year-old women with high (n = 19) and low (n = 17) calcaneal bone mineral density (BMD, g/cm3) previously measured by 125I-photon absorption. The high BMD group had a 20-21% higher tibial BMD and 9-12% higher bone cross-sectional area than was observed in the low BMD group. The distribution of bone mass indicated that the low BMD group had lost bone mainly from the endosteal surface, especially in the anterior part of the tibia. However, both groups had a similar basic pattern of mass distribution at the measured sections. The high BMD group had highe…

musculoskeletal diseasesBone densityEndocrinology Diabetes and MetabolismBody Mass IndexFractures BoneAbsorptiometry PhotonBone DensityRisk FactorsmedicineAnimalsHumansOrthopedics and Sports MedicineTibiaAgedBone mineralOrthodonticsTibiaBody WeightBiomechanicsAnatomymusculoskeletal systemBiomechanical PhenomenaCalcaneusmedicine.anatomical_structureCattleFemaleCortical boneTomographyCalcaneusBody mass indexMathematicsTomography Emission-ComputedJournal of Bone and Mineral Research
researchProduct

Biomechanical testing of different posterior fusion devices on lumbar spinal range of motion.

2019

Abstract Background Recent minimal-invasive posterior fusion devices are supposed to provide stability and obtain fusion in combination with interbody cages in the instrumented segment. The aim of the present study is to evaluate the primary stability of two minimal-invasive posterior prototypes compared to an established spinous process plate and standard pedicle screw instrumentation. Methods Seven fresh frozen human cadaver lumbar spines (L2–L5) were tested in a spinal testing device with a moment of 7.5 Nm. Spinal stability was determined as mean range of motion (RoM) in the segment L3/L4 during extension-flexion, lateral bending and axial rotation. The RoM was measured during five cond…

musculoskeletal diseasesFacet (geometry)Materials scienceRotationBiophysics03 medical and health sciencesFixation (surgical)0302 clinical medicineLumbarCadaverBone platemedicineCadaverHumansOrthopedics and Sports MedicineRange of Motion ArticularLumbar VertebraeBiomechanicsLumbosacral RegionLumbar spinal stenosis030229 sport sciencesmusculoskeletal systemmedicine.diseaseBiomechanical PhenomenaSpinal FusionRange of motionBone Plates030217 neurology & neurosurgeryBiomedical engineeringClinical biomechanics (Bristol, Avon)
researchProduct

Biomechanische Überlegungen über Stoßkräfte und Fußstabilität beim Laufen

1993

The interaction between "man-shoe and surface" is presented as a model to discuss the complexity of human locomotion. Only if the physiological system "man" interacts positively with the physical requirements of shoe and surface quality running will become effective and economical. Especially during the early ground contact phase the hardness of the shoe construction determines the height of the vertical impact load. These adaptations have consequences in the emg amplitudes during the stretch activation phase of the contact. Comparing various jogging shoes with altered construction properties it can be shown that the "hardness" of the shoe material is well adapted by the variation in the em…

musculoskeletal diseasesFoot (prosody)Computer sciencebusiness.industrytechnology industry and agricultureEMG amplitudeStructural engineeringFlexor musclesStability (probability)Biomechanical Phenomenabody regionsGround contactotorhinolaryngologic diseasesOrthopedics and Sports MedicineRange of motionbusinessHuman locomotionSportverletzung · Sportschaden
researchProduct

Altered (oxidized) C1q induces a rheumatoid arthritis-like destructive and chronic inflammation in joint structures in arthritis-susceptible rats.

1997

Previous studies have identified an altered C1q molecule in synovial fluids from the joints of rheumatoid arthritis patients. We therefore immunized arthritis-susceptible Lewis 1A.AVN rats with either native C1q (C1q nat), altered (oxidized) C1q (C1q ox), or type II collagen (CII, induces arthritis in these animals), in order to induce arthritis. Unlike C1q nat, both CII and C1q ox were able to induce swelling and erythema of joints consistent with an arthritis-like inflammatory reaction. Histopathological evaluation of individual joint sections revealed synovitis, bursitis and tendovaginitis, massive joint destruction, and severe pannus formation. In a time-course study, no differences in …

musculoskeletal diseasesImmunologyType II collagenArthritischemical and pharmacologic phenomenaInflammationPathology and Forensic Medicinefluids and secretionsAntigenimmune system diseasesSynovitismedicineImmunology and AllergyAnimalsskin and connective tissue diseasesAutoimmune diseaseInflammationbiologybusiness.industryArthritisComplement C1qmedicine.diseaseRatsRats Inbred LewRheumatoid arthritisImmunologybiology.proteinFemaleJointsmedicine.symptomAntibodybusinessOxidation-ReductionClinical immunology and immunopathology
researchProduct

Interleukin 10 polymorphisms in ankylosing spondylitis.

2003

Genetic polymorphisms of the IL10 promoter region have been implicated in many autoimmune diseases, including seronegative spondyloarthropathies. We studied three SNPs (IL10-1087, -824, and -597) and two microsatellites (IL10R and IL10G) lying within the promoter region of IL10 for association with susceptibility to and clinical manifestations of ankylosing spondylitis (AS), a common form of spondyloarthritis. Four hundred and sixty-eight individuals from 182 Finnish families affected with AS were studied. No association between individual IL10 promoter region polymorphisms or marker haplotype was observed with susceptibility to AS, but weak association was noted between the IL10-597 and -8…

musculoskeletal diseasesImmunologychemical and pharmacologic phenomenaSingle-nucleotide polymorphismBiologyPolymorphism Single Nucleotideimmune system diseasesparasitic diseasesGeneticsmedicineSNPHumansSpondylitis AnkylosingAlleleSpondylitisGenetics (clinical)AllelesGenetic associationGeneticsAnkylosing spondylitisPolymorphism GeneticHaplotypehemic and immune systemsmedicine.diseaseInterleukin-10ImmunologyBASFIMicrosatellite Repeats
researchProduct

Kinematics of Cervical Spine during Rowing Ergometer at Different Stroke Rates in Young Rowers: A Pilot Study

2022

Background: Research on biomechanics in rowing has mostly focused on the lumbar spine. However, injuries can also affect other body segments. Thus, the aim of this pilot study was to explore any potential variations in the kinematics of the cervical spine during two different stroke rates on the rowing ergometer in young rowers. Methods: Twelve young rowers of regional or national level were recruited for the study. The experimental protocol consisted of two separate test sessions (i.e., a sequence of 10 consecutive strokes for each test session) at different stroke rates (i.e., 20 and 30 strokes/min) on an indoor rowing ergometer. Kinematics of the cervical spine was assessed using an iner…

musculoskeletal diseasesLumbar VertebraerowingErgometryHealth Toxicology and MutagenesisPublic Health Environmental and Occupational HealthPilot Projectscervical range of motionAthletic PerformancebiomechanicsBiomechanical Phenomenarange of motioncervical mobilityjoint mobility; range of motion; biomechanics; kinematics; sport performance; cervical mobility; cervical range of motion; rowing; stroke cycle; stroke ratekinematicsCervical Vertebraesport performancestroke cyclejoint mobilitystroke rateWater SportsInternational Journal of Environmental Research and Public Health
researchProduct

Modulation of type II collagen-induced arthritis in DBA/1 mice by intravenous application of a peptide from the C1q-A chain.

1992

In this report we are able to show that intravenous (i.v.) application (day 0) of a nonapeptide (residues 26-34) from the human C1q A-chain (designated peptide A-C1q) prior to intradermal (i.d.) administration of chicken type II collagen (CII) in arthritis-susceptible DBA/1 mice (H2q), leads to abrogation of polymorphonuclear neutrophil (PMN) invasion into the joints. This nonapeptide exhibits epitope characteristics and high homology to residues 137-147 of CB11 (a cyanogen bromide fragment of chicken CII, known to contain both arthritis inducing and suppressing determinants). Arthritis index was lowest in animals pretreated i.v. with CII (as internal control), though animals pretreated i.v…

musculoskeletal diseasesMaleInjections IntradermalImmunologyMolecular Sequence DataType II collagenArthritischemical and pharmacologic phenomenaPeptideEpitopechemistry.chemical_compoundMiceAntigenAdjuvants ImmunologicmedicineImmunology and AllergyAnimalsAmino Acid Sequenceskin and connective tissue diseasesPeptide sequencechemistry.chemical_classificationbiologyArthritisComplement C1qHematologymedicine.diseaseMolecular biologyPeptide FragmentschemistryMice Inbred DBAImmunologyAntibody FormationInjections Intravenousbiology.proteinCyanogen bromideCollagenAntibodyOligopeptidesImmunobiology
researchProduct

Mechanical activity of small and large intestine in normal and mdx mice: a comparative analysis.

1999

The aim of this study was to compare the motor pattern (recorded as changes in intraluminal pressure) of isolated duodenum and proximal colon between dystrophic mdx and normal mice. When duodenal recordings from control preparations were compared with mdx mice there was no significant difference in the spontaneous motor pattern, responses to electrical nerve stimulation or sensitivity to pharmacological agents. Colonic segments from mdx mice showed a more complex motor pattern, consisting of contractions with amplitude and frequency similar to those of controls and by additional contractions with lower amplitude and higher frequency. Moreover, 70% of the colonic preparations from mdx mice d…

musculoskeletal diseasesMalecongenital hereditary and neonatal diseases and abnormalitiesmedicine.medical_specialtyNerve stimulationPhysiologyColonDuodenumDuchenne muscular dystrophyIn Vitro TechniquesInhibitory postsynaptic potentialNitric oxidechemistry.chemical_compoundMiceReference ValuesInternal medicineIntestine SmallmedicineAnimalsLarge intestineProximal colonIntestine LargeEndocrine and Autonomic SystemsChemistrySignificant differenceGastroenterologyAnatomyMuscular Dystrophy Animalmusculoskeletal systemmedicine.diseaseElectric StimulationBiomechanical PhenomenaMice Inbred C57BLmedicine.anatomical_structureEndocrinologyDuodenumMice Inbred mdxGastrointestinal MotilityNeurogastroenterology and motility : the official journal of the European Gastrointestinal Motility Society
researchProduct

Biomechanical effectiveness of a distraction-rotation knee brace in medial knee osteoarthritis: preliminary results.

2013

Abstract Background Non-pharmacological therapies are recommended for the care of knee osteoarthritis patients. Unloader knee braces provide an interesting functional approach, which aims to modulate mechanical stress on the symptomatic joint compartment. We aimed to confirm the biomechanical effects and evaluate functional benefits of a new knee brace that combines a valgus effect with knee and tibial external rotation during gait in medial osteoarthritis patients. Methods Twenty patients with unilateral symptomatic medial knee osteoarthritis were included and they performed two test sessions of 3D gait analysis with and without the brace at the initial evaluation (W0) and after 5weeks (W5…

musculoskeletal diseasesMalemedicine.medical_specialtyWOMACVisual Analog ScaleOsteoarthritisPhysical medicine and rehabilitationmedicineHumansOrthopedics and Sports MedicineProspective StudiesGaitBracesbiologybusiness.industryEquipment DesignMiddle AgedOsteoarthritis Kneemusculoskeletal systembiology.organism_classificationmedicine.diseaseGaitBraceBiomechanical PhenomenaPreferred walking speedValgusmedicine.anatomical_structurePatient SatisfactionGait analysisFemaleAnklebusinesshuman activitiesLocomotionThe Knee
researchProduct