Search results for "photopic vision"

showing 10 items of 55 documents

Impact of lens material on objective refraction in eyes with trifocal diffractive intraocular lenses

2021

Purpose: Compare subjective (Rx) and objective (ObjRx) refractions outcomes with two autorefractors models and an aberrometer in eyes implanted with a hydrophobic trifocal IOL (FineVision POD F GF, Physiol, Liége, Belgium) and a hydrophilic one (FineVision POD F, Physiol, Liége, Belgium). Methods: Prospective comparative cohort study, with 100 subjects randomly assigned to either the POD F group (n = 50) or the POD F-GF group (n = 50). Postoperative eye examinations at 1-month visit included seven result sets, one for each assessment method: Rx, AR (automated refraction measured with the autorefractor KR8800), WF-P (Zernike-coefficients-based objective refraction, photopic pupil size), WF-M…

Malemedicine.medical_specialtyPseudophakiaMesopic visionmedicine.medical_treatmentVisual AcuityUlls -- Acomodació i refraccióIntraocular lensRefraction OcularIntraocular lensesPupillaw.invention03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicinelawOphthalmologymedicineHumansPostoperative PeriodProspective StudiesMathematicsAgedEye -- Accomodation and refractionVision BinocularIntraocular lensOpticsTrifocal diffractiveLents intraocularsHydrofilicRefractionSubjective refractionMultifocal Intraocular LensesSensory SystemsLens (optics)OphthalmologyRefractionAutorefractorPatient SatisfactionDifracció030221 ophthalmology & optometryFemale:Ciències de la visió [Àrees temàtiques de la UPC]Diffraction030217 neurology & neurosurgeryHydrofobicPhotopic visionFollow-Up Studies
researchProduct

Optical and visual performance of diffractive intraocular lens implantation after myopic laser in situ keratomileusis

2008

To evaluate the optical and visual quality in eyes with diffractive intraocular lenses (IOLs) after myopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.The best corrected visual acuity (BCVA [distance]) at 12.5%, 25.0%, and 100% contrasts under photopic and mesopic conditions; best distance-corrected near acuity; corneal total higher-order aberrations (HOAs); and optical quality by modulation transfer function (MTF) were measured after myopic LASIK in eyes with a spherical AcrySof ReSTOR SN60D3 IOL or an aspheric Acri.LISA 366D IOL and phakic eyes (control).Under photopic conditions at 100% contrast, the BCVA was 0.1 logMAR or better in all g…

Malemedicine.medical_specialtyRefractive errorPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentKeratomileusis Laser In SituVisual AcuityKeratomileusisIntraocular lensProsthesis DesignCataractPupilContrast SensitivityLens Implantation IntraocularOphthalmologyMyopiamedicineHumansProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryLASIKPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyOptometryFemaleLasers ExcimerSurgerysense organsbusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual quality after diffractive intraocular lens implantation in eyes with previous hyperopic laser in situ keratomileusis

2010

To evaluate distance, intermediate, and near visual quality in eyes with diffractive intraocular lens (IOL) implantation after previous hyperopic laser in situ keratomileusis (LASIK).Fernández-Vega Ophthalmological Institute, Oviedo, Spain.Cohort study.Corrected distance visual acuity (CDVA) at 12.5%, 25.0%, and 100% contrast levels under photopic and mesopic conditions; uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, defocus curves, and corneal higher-order aberrations (HOAs) were measured in eyes that had AcrySof Restor SN60D3 spherical IOL implantation (study group) and in phakic eyes (control group) after hyperopic LASIK.Under photopic conditions at 100% contrast, …

Malemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentKeratomileusis Laser In SituMesopic VisionVisual AcuityIntraocular lensKeratomileusisRefraction OcularCohort StudiesLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesAgedPostoperative CarePhacoemulsificationColor Visionbusiness.industryLASIKPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleLasers ExcimerSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual Acuity and Contrast Sensitivity in Eyes Implanted with Aspheric and Spherical Intraocular Lenses

2009

Purpose To compare visual acuity and contrast sensitivity (CS) in eyes implanted with aspheric and spherical intraocular lenses (IOLs) after cataract surgery. Design Randomized, prospective study. Participants Five hundred twenty-four eyes from 262 cataract surgery patients implanted with 2 IOL models: the AcrySof IQ (262 eyes) and AcrySof SN60AT (262 eyes; Alcon Laboratories, Fort Worth, TX). Methods High-contrast photopic best-corrected distance visual acuity (BCVA) and CS under photopic (85 cd/m 2 ) and mesopic (6 cd/m 2 ) conditions were measured. Pupil diameter was analyzed for distance vision under both lighting conditions. Follow-up was carried out for 6 months in all patients. Main …

Malemedicine.medical_specialtyVisual acuityLightPseudophakiagenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentAcrylic ResinsVisual AcuityDark AdaptationIntraocular lensCataract ExtractionProsthesis DesignContrast SensitivityLens Implantation IntraocularVision MonocularOphthalmologymedicineHumansContrast (vision)Prospective StudiesAgedmedia_commonLenses Intraocularbusiness.industryPupilCataract surgeryeye diseasesOphthalmologyAlcon LaboratoriesIntraocular lensesOptometryFemalesense organsmedicine.symptombusinessPhotopic visionOphthalmology
researchProduct

Optical quality of the eye after lens replacement with a pseudoaccommodating intraocular lens

2007

To examine the optical quality of healthy presbyopic eyes before and after implantation of the pseudoaccommodating AcrySof ReSTOR Natural intraocular lens (IOL) (Alcon Laboratories) by measuring visual acuity and wavefront aberrations.University of Valencia, Fernández-Vega Ophthalmological Institute, Valencia, Spain.Monocular refraction and photopic distance (6 m) and near (0.33 m) visual acuities were determined before and after clear lens extraction with bilateral AcrySof ReSTOR Natural IOL implantation in 30 hyperopic eyes (+0.50 to +4.00 diopters [D]) of presbyopic patients with low astigmatism (or = 1.00 D). Postsurgical binocular visual acuity was measured over a range of effective di…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensAstigmatismProsthesis DesignPupillaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineHumansDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryAccommodation OcularPresbyopiaPhacoemulsificationMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyHyperopiaOptometryFemaleSurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Visual Function after Implantation of a Presbyopia-Correcting Trifocal Intraocular Lens

2019

<b><i>Purpose:</i></b> To evaluate distance, intermediate, and near visual performance in patients implanted with a trifocal aspheric presbyopia-correcting intraocular lens (IOL). <b><i>Methods:</i></b> Forty patients were bilaterally implanted with the AcrySofIQ PanOptix IOL after femtosecond laser-assisted lens surgery. Binocular best corrected distance visual acuity (CDVA) (4 m), best distance-corrected near visual acuity (DCNVA) (40 and 30 cm), best corrected distance intermediate visual acuity (DCIVA) (70, 60, and 50 cm), binocular distance contrast sensitivity under photopic conditions (85 cd/m<sup>2</sup>), and defocus curve…

Malemedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityIntraocular lensProsthesis DesignRefraction Ocularlaw.inventionCellular and Molecular NeuroscienceLens Implantation IntraocularlawOphthalmologyHumansMedicineContrast (vision)In patientRetrospective Studiesmedia_commonVision BinocularColor Visionbusiness.industryGeneral MedicinePresbyopiaMiddle Agedmedicine.diseaseMultifocal Intraocular Lenseseye diseasesSensory SystemsLens (optics)OphthalmologyVisual functionFemalemedicine.symptombusinessFollow-Up StudiesPhotopic visionOphthalmic Research
researchProduct

Visual Comparison of an Artificial Pupil Contact Lens to Monovision

2012

PURPOSE To assess and compare the effects of contact-lens based artificial pupil design and monovision correction on visual performance. METHODS In a cross-over study design, 22 presbyopic patients (age range 50 to 64 years) were evaluated using artificial pupil contact lens on the non-dominant eye and monovision. After 1 month, binocular distance visual acuity (BDVA), binocular near visual acuity (BNVA), defocus curve, binocular distance contrast sensitivity, binocular near contrast sensitivity, and stereoacuity were measured, under photopic conditions (85 cd/m2), in each patient after contact lens fitting. Moreover, BDVA and binocular distance contrast sensitivity were examined under meso…

Malemedicine.medical_specialtyVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual AcuityPupilVision MonocularOphthalmologymedicineHumansContrast (vision)media_commonMathematicsCross-Over StudiesPupilEquipment DesignPresbyopiaMiddle Agedeye diseasesContact lensStereoscopic acuityOphthalmologyTreatment OutcomeFemaleSpatial frequencymedicine.symptomFollow-Up StudiesOptometryPhotopic visionOptometry and Vision Science
researchProduct

Visual Performance of a Multifocal Toric Soft Contact Lens

2012

PURPOSE To evaluate the visual performance of the Proclear multifocal toric contact lens (CL; CooperVision, US) for both presbyopia and astigmatism correction. METHODS In this crossover study design, 20 presbyopic subjects with astigmatism were fitted in a random order with either Proclear multifocal toric CL or Proclear toric single vision distance CL (DCL) combined with reading spectacles. After 1 month, high-contrast distance visual acuity, near high-contrast visual acuity, distance contrast sensitivity (CS) under photopic and mesopic conditions without and with glare, near CS, defocus curve, and stereopsis were measured. Subjects were then refitted with the alternative correction, and t…

Malemedicine.medical_specialtyVisual acuitygenetic structuresMesopic visionmedia_common.quotation_subjectVisual AcuityAstigmatismRefraction OcularOphthalmologymedicineHumansContrast (vision)AgedMathematicsmedia_commonCross-Over StudiesGlare (vision)Equipment DesignPresbyopiaMiddle AgedContact Lenses HydrophilicRefractive Errorsmedicine.diseaseeye diseasesContact lensOphthalmologyFemalemedicine.symptomOptometryPhotopic visionOptometry and Vision Science
researchProduct

Visual function after implantation of an aspheric bifocal intraocular lens.

2009

Purpose To evaluate distance, intermediate, and near vision after bifocal aspheric AcrySof ReSTOR SN6AD1 intraocular lens (IOL) implantation. Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods Binocular distance best corrected visual acuity (BCVA) (4.0 m), best distance-corrected near (40.0 cm) and intermediate (70.0, 60.0, 50.0 cm) acuities, and contrast sensitivity under photopic (85.0 candelas [cd]/m 2 ) and mesopic (3.0 cd/m 2 ) conditions with and without glare were measured postoperatively. A patient-satisfaction and visual phenomena questionnaire was administered. Results Six months postoperatively, the mean acuities (logMAR) were binocular BCVA, −0.064 ± 0.049…

Malemedicine.medical_specialtygenetic structuresMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVisual AcuityIntraocular lensProsthesis DesignContrast SensitivityLens Implantation IntraocularOphthalmologySurveys and QuestionnairesMedicineContrast (vision)HumansProspective StudiesDioptremedia_commonAgedLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)Middle Agedeye diseasesSensory SystemsOphthalmologyPatient SatisfactionVisual DisturbanceOptometrySurgeryFemaleSpatial frequencybusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct

Visual function after bilateral implantation of a new zonal refractive aspheric multifocal intraocular lens.

2011

Purpose To evaluate visual function after bilateral implantation of a zonal refractive aspheric multifocal intraocular lens (IOL). Setting Private practice surgery center, Valencia, Spain. Design Cohort study. Methods Consecutive eyes with cataract had bilateral implantation of Lentis Mplus LS-312 multifocal IOLs. Distance, intermediate, and near visual acuities; contrast sensitivity; defocus curves; and a quality-of-vision questionnaire, including presence of halos or dysphotopsia, were evaluated 6 months postoperatively. A control group of age-matched monofocal pseudophakic patients was included to compare contrast sensitivity function. Results In the multifocal group, the mean binocular …

Malemedicine.medical_specialtygenetic structuresPseudophakiaMesopic visionmedia_common.quotation_subjectmedicine.medical_treatmentVision DisordersVisual AcuityIntraocular lensProsthesis DesignCohort StudiesContrast SensitivityLens Implantation IntraocularOphthalmologySurveys and QuestionnairesmedicineContrast (vision)HumansProspective Studiesmedia_commonAgedLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryGlare (vision)PhacoemulsificationMultifocal intraocular lensMiddle Agedeye diseasesSensory SystemsOphthalmologyPrivate practiceQuality of LifeOptometrySurgeryFemalesense organsbusinessPhotopic visionJournal of cataract and refractive surgery
researchProduct