Search results for "pillar"

showing 10 items of 877 documents

Field testing parameter sensitivity of the two-term infiltration equation using differentiated linearization

2003

Knowledge of soil hydraulic conductivity in the vadose zone is important in many agronomic, engineering and environmental areas. Transient tension infiltrometer experiments can be used to estimate the hydraulic conductivity, K0, corresponding to a given pressure head by the single-test (TST) method that uses the coefficients C1 and C2 of the two-term infiltration equation. The “Differentiated Linearization” (DL) method has been proposed to estimate these coefficients when a layer of contact material is used for the experiment. A field test of the DL and TST methods was conducted on a sandy loam and a clay soil. Eliminating the early-time influence of the contact layer was easy when the sorp…

Capillary actionSorptivitySoil hydraulic conductivitySoil SciencePressure headInfiltration (hydrology)Hydraulic conductivitytension infiltrometerLoamVadose zoneSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-ForestaliInfiltrometerGeotechnical engineeringMathematics
researchProduct

Real-time microfluorescence studies of Langmuir-Blodgett deposition: Monolayer adsorption and desorption

1990

Abstract Observations of the meniscus region in a typical Langmuir-Blodgett configuration are obtained using fluorescence microscopy. Studies of the meniscus position as a function of pH demonstrate that the meniscus height increases upon charging the monolayer owing to the repulsive interaction between monolayer and substrate surfaces. Through the correspondence between meniscus height and contact angle the adhesion forces between monolayer and substrate as a function of monolayer charge are assessed. The phenomenon of desorption upon resubmerging a deposited film is described and it is shown that the meniscus height at the onset of the desorption is greater for higher pH.

Capillary condensationChemistryMetals and AlloysAnalytical chemistrySurfaces and InterfacesSubstrate (electronics)musculoskeletal systemLangmuir–Blodgett filmSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialsbody regionsContact angleAdsorptionDesorptionMonolayerMaterials ChemistryMeniscusThin Solid Films
researchProduct

Pore Size Analysis of MCM-41 Type Adsorbents by Means of Nitrogen and Argon Adsorption

1998

Methods of nonlocal density functional theory (NLDFT), proposed recently for predictions of adsorption equilibrium and calculations of pore size distributions in micro- and mesoporous materials, were tested on reference MCM-41 materials. Five newly synthesized MCM-41 adsorbents with presumably uniform pore channels varying from 32 to 45 Å were characterized by X-ray diffraction (XRD), nitrogen adsorption at 77 K, and argon adsorption at 77 and 87 K. New sets of intermolecular interaction parameters of the NLDFT model for N2 and Ar adsorption on MCM-41 were determined. The parameters were specified to reproduce the bulk liquid-gas equilibrium densities and pressures, liquid-gas interfacial t…

Capillary condensationNanoporousChemistryMineralogyThermodynamicsFlory–Huggins solution theoryMolecular sieveSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsBiomaterialsColloid and Surface ChemistryAdsorptionDesorptionZeoliteMesoporous materialJournal of Colloid and Interface Science
researchProduct

QS159. Structural Adaptations Increase Mucosal Capillary Density in Prolonged Murine Colitis

2008

Capillary densityChemistryImmunologyMurine colitisSurgeryJournal of Surgical Research
researchProduct

Acrylate ester-based monolithic columns for capillary electrochromatography separation of triacylglycerols in vegetable oils

2011

Abstract A simple and reliable method for the evaluation of triacylglycerols (TAGs) in vegetable oils by capillary electrochromatography (CEC) with UV–Vis detection, using octadecyl acrylate (ODA) ester-based monolithic columns, has been developed. The percentages of the porogenic solvents in the polymerization mixture, and the mobile phase composition, were optimized. The optimum monolith was obtained at the following ratios: 40:60% (wt/wt) monomers/porogens, 60:40% (wt/wt) ODA/1,3-butanediol diacrylate and 23:77% (wt/wt) 1,4-butanediol/1-propanol (14 wt% 1,4-butanediol in the polymerization mixture). A satisfactory resolution between TAGs was achieved in less than 12 min with a 65:35 (v/v…

Capillary electrochromatographyAcrylategeographyChromatographygeography.geographical_feature_categoryResolution (mass spectrometry)Organic ChemistryDiscriminant Analysis1-PropanolGeneral MedicineBiochemistryAnalytical Chemistrychemistry.chemical_compoundMonomerVegetable oilAcrylateschemistryPolymerizationCapillary ElectrochromatographyMicroscopy Electron ScanningPlant OilsMonolithButylene GlycolsAmmonium acetateTriglyceridesJournal of Chromatography A
researchProduct

Preparation and characterization of hexyl methacrylate monolithic columns for CEC

2008

The preparation of hexyl methacrylate (HMA) monolithic columns for CEC separations has been investigated with two initiation systems: (i) ammonium peroxodisulphate and TEMED to activate the polymerization reaction, and (ii) by thermal initiation with AIBN. For both initiators, the influence of composition of porogenic solvent on morphological and chromatographic properties of monoliths was investigated. Two porogenic solvent systems, aqueous and non-aqueous media, were also studied for monolithic beds polymerized with AIBN. Under optimal conditions, low minimum plate heights (9.6 mum for peroxodisulphate, 8.4 and 10.0 mum for AIBN in aqueous and non-aqueous porogenic solvents, respectively)…

Capillary electrochromatographyChromatographyAqueous solutionChemistryClinical BiochemistryAcrylic ResinsReproducibility of ResultsRepeatabilityEthylenediaminesMethacrylateBiochemistryAnalytical ChemistrySolventPolymerizationCapillary Electrochromatographyvisual_artMicroscopy Electron Scanningvisual_art.visual_art_mediumMethacrylatesAcrylic resinHexyl methacrylateELECTROPHORESIS
researchProduct

Pressurized flow electrochromatography with reversed phase capillary columns

1995

Pressurized flow electrochromatography (PEC) is a hybrid of capillary LC and capillary electroendosmotic chromatography (CEC). Both a pressure gradient and an electric field are applied across a packed capillary. The feasability of a simple, easy to handle PEC instrumentation is demonstrated. Home made capillary columns with four different silica-based reversed phase packings have been operated under PEC conditions separating non ionic and ionic low molecular weight analytes. The capillary columns have been characterized with respect to their separation efficiency and selectivity and the results have been compared to those obtained with the purely pressure driven system. An electrochromatog…

Capillary electrochromatographyChromatographyCapillary electrophoresisElectrochromatographyChemistryCapillary actionPhase (matter)Analytical chemistryReversed-phase chromatographyBiochemistryCapacity factorPressure gradientAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

Influence of temperature on the behaviour of small linear peptides in capillary electrochromatography

2000

The influence of temperature, T, on the retention times, peak widths, peak symmetry coefficients and theoretical plate numbers of two small linear peptides, [Met5]enkephalin and [Leu5]enkephalin, has been studied with capillary electrochromatography (CEC) capillary columns of 100 microm I.D. and 250 mm packed length with a total length of 335 mm, containing 3 microm Hypersil n-octadecyl bonded silica. With increasing column temperature from 15 to 60 degrees C, the electroosmotic flow (EOF) and the column efficiencies increased, whereas the retention coefficients (Kcec) of both peptides decreased. A linear relationship was found between the EOF value and the square root of the temperature ov…

Capillary electrochromatographyChromatographyChemistryCapillary actionOrganic ChemistryTemperatureAnalytical chemistryElectro-osmosisGeneral MedicineReversed-phase chromatographyAtmospheric temperature rangeBiochemistryAnalytical ChemistryColumn chromatographyElectrochromatographyTheoretical platePeptidesChromatography Micellar Electrokinetic CapillaryJournal of Chromatography A
researchProduct

Peroxodisulfate as a chemical initiator for methacrylate-ester monolithic columns for capillary electrochromatography

2008

Organic monolithic stationary phases for CEC were synthesized in situ in fused-silica capillaries. Polymerization mixtures were composed of butyl methacrylate, ethylene dimethacrylate, and [2-(methacryloyloxy)ethyl]trimethyl ammonium chloride in the presence of a porogenic solvent, using ammonium peroxodisulfate as chemical initiator, and N,N,N',N'-tetramethylethylenediamine to activate the reaction. The influence of the amount of initiator, temperature, and composition of porogenic solvent on the physical and chromatographic properties of monolithic stationary phases has been investigated. A minimum plate height of 14.5 microm was obtained at 18 wt% of 1,4-butanediol in the polymerization …

Capillary electrochromatographyChromatographySilicon dioxideClinical BiochemistryAcrylic ResinsAzobisisobutyronitrileEthylenediaminesSilicon DioxideMethacrylateBiochemistryAnalytical ChemistrySolventchemistry.chemical_compoundchemistryPolymerizationAmmonium SulfateCapillary ElectrochromatographyNitrilesMethacrylatesAmmoniumAmmonium chloridePorosityNuclear chemistryELECTROPHORESIS
researchProduct

A critical appraisal of capillary electrochromatography.

2002

Although still in its infancy, CEC promises some advantages over competitive techniques for separating charged analytes including biomolecules.

Capillary electrochromatographyCritical appraisalSpectrometry Mass Electrospray IonizationChemistryElectrophoresis CapillaryProteinsNanotechnologyEquipment DesignPeptidesChromatography High Pressure LiquidAnalytical ChemistryAnalytical chemistry
researchProduct