Search results for "plasma physics"
showing 10 items of 393 documents
X-ray imaging of the heating zone of non-normal incidence pumped XRL plasma
2006
Soft x-ray emission, above 600 eV, from a grazing incidence pumped Ni-like Mo x-ray laser (GRIP-XRL) [1] plasma was investigated. Using a pinhole camera looking along the target surface, perpendicular to the direction of the XRL emission, spatially-resolved information was obtained with a resolution which was limited only by the pinhole size of 10 μm. The relative distance from the target surface to the plasma zone heated by th e picosecond pulse was investigated for different GRIP angles, energy ratios and delays between the plasma producing and the plasma heating pulses.
Some Advantages of the Gyrotrons with Width Emitters
2020
The main trends in gyrotron development are escalation of the radiated power and increasing the frequency of coherent radiation. For both trends it is beneficial to develop gyrotrons with wide emitters because this allows one to use cryomagnets with smaller inner bore sizes. For analyzing and optimizing the operation of gyrotrons with wide emitters it is proposed to represent such emitters as a superposition of thin rings and analyze the properties of electron beams emitted by each of these rings. The analysis of electron beam properties, for electron optical systems with different emitters is presented. The possibility to reduce velocity spread by anode profiling is discussed. The dynamics…
Ultrapure laser-synthesized Si nanoparticles with variable oxidation states for biomedical applications
2020
We employ a method of femtosecond laser fragmentation of preliminarily prepared water-dispersed microcolloids to fabricate aqueous solutions of ultrapure bare Si-based nanoparticles (Si-NPs) and assess their potential for biomedical applications. The nanoparticles appear spherical in shape, with low size dispersion and a controllable mean size, from a few nm to several tens of nm, while a negative surface charge (−35 mV ± 0.10 according to z-potential data) provides good electrostatic stabilization of colloidal Si-NP solutions. Structural analysis shows that the Si-NPs are composed of Si nanocrystals with inclusions of silicon oxide species, covered by a SiOx (1 < x < 2) shell, while the to…
Photo-assisted O− and Al− production with a cesium sputter ion source
2021
It has been recently proposed that the production of negative ions with cesium sputter ion sources could be enhanced by laser-assisted resonant ion pair production. We have tested this hypothesis by measuring the effect of pulsed diode lasers at various wavelengths on the O− and Al− beam current produced from Al2O3 cathode of a cesium sputter ion source. The experimental results provide evidence for the existence of a wavelength-dependent photo-assisted enhancement of negative ion currents but cast doubt on its alleged resonant nature as the effect is observed for both O− and Al− ions at laser energies above a certain threshold. The beam current transients observed during the laser pulses s…
Periodic unmixing of a binary metallic vapor
2005
We report on a type of surface structuring after short pulse laser ablation of a binary alloy. We observe the emergence of a concentric ring structure with changing elemental composition. The composition changes are interpreted by condensation of the ambient ablation vapor due to stress wave excitations in the ablation spot.
The effect of gas mixing and biased disc voltage on the preglow transient of electron cyclotron resonance ion source
2012
The effect of gas mixing and biased disc voltage on the preglow of electron cyclotron resonance ion source plasma has been studied with the AECR-U type 14 GHz ion source. It was found that gas mixing has a significant effect on the preglow. The extracted transient beam currents and efficiency of the heavier species increase, while the currents and efficiency of the lighter species decrease when gas mixing is applied. The effect of the biased disc was found to be pronounced in continuous operation mode in comparison to preglow. The data provide information on the time scales of the plasma processes explaining the effects of gas mixing and biased disc. The results also have implications on pr…
Microwave emission from ECR plasmas under conditions of two-frequency heating induced by kinetic instabilities
2018
Multiple frequency heating is one of the most effective techniques to improve the performances of ECR ion sources. It has been demonstrated that the appearance of the periodic ion beam current oscillations in ECRIS at high heating power and low magnetic field gradient is associated with kinetic plasma instabilities. Recently it was proven that one of the main features of multiple frequency heating is connected with stabilizing effect, namely the suppression of electron cyclotron instability in ECRIS plasmas. Due to this kind of stabilization it is possible to run the ion source in stable mode using higher total microwave power and thus to obtain better ion beam parameters. Unfortunately, ev…
The extraction of negative carbon ions from a volume cusp ion source
2017
Acetylene and carbon dioxide gases are used in a filament-powered volume-cusp ion source to produce negative carbon ions for the purpose of carbon implantation for gettering applications. The beam was extracted to an energy of 25 keV and the composition was analyzed with a spectrometer system consisting of a 90° dipole magnet and a pair of slits. It is found that acetylene produces mostly C−2 ions (up to 92 µA), while carbon dioxide produces mostly O− with only trace amounts of C−. Maximum C−2 current was achieved with 400 W of arc power and, the beam current and composition were found to be highly dependent on the pressure in the source. The beam properties as a function of source settings…
Electron cyclotron resonance ion source plasma chamber studies using a network analyzer as a loaded cavity probe
2012
A method and first results utilizing a network analyzer as a loaded cavity probe to study the resonance properties of a plasma filled electron cyclotron resonance ion source (ECRIS) plasma chamber are presented. The loaded cavity measurements have been performed using a dual port technique, in which two separate waveguides were used simultaneously. One port was used to ignite and sustain the plasma with a microwave source operating around 11 GHz and the other was used to probe the cavity properties with the network analyzer using a frequency range around 14 GHz. The first results obtained with the JYFL 14 GHz ECRIS demonstrate that the presence of plasma has significant effects on the reson…
Production of negative osmium ions by laser desorption and ionization.
2010
The interest to produce negative osmium ions is manifold in the realm of high-accuracy ion trap experiments: high-resolution nearly Doppler-free laser spectroscopy, antihydrogen formation in its ground state, and contributions to neutrino mass spectrometry. Production of these ions is generally accomplished by sputtering an Os sample with Cs(+) ions at tens of keV. Though this is a well-established method commonly used at accelerators, these kind of sources are quite demanding and tricky to operate. Therefore, the development of a more straightforward and cost effective production scheme will be of benefit for ion trap and other experiments. Such a scheme makes use of desorption and ionizat…