Search results for "plates"
showing 10 items of 123 documents
Multispectral analysis of color vision deficiency tests
2011
Color deficiency tests are usually produced by means of polygraphy technologies and help to diagnose the type and severity of the color deficiencies. Due to different factors, as lighting conditions or age of the test, standard characteristics of these tests fail, thus not allowing diagnosing unambiguously the degree of different color deficiency. Multispectral camera was used to acquire the spectral images of the Ishihara and Rabkin pseudoisochromatic plates in the visible spectrum. Spectral data was converted to cone signals, and successive mathematics applied to provide a simple simulation of the test performance. Colorimetric data of the each pixel of the test image can be calculated an…
Analysis of the effects of magnetic field on the induced stress in drilled plates
2013
Abstract A drilled plate of ferromagnetic material suitably coupled by coils of enameled copper wire fed by a DC power supply to 30 V is considered in this paper. It is analyzed with finite element and later experiments are performed to validate the obtained results. After polishing the plate, two strain gauges for measuring the deformation along the x axis and along the z axis are installed. The values of strain are 5 μm/m in z direction and −2 μm/m in x direction. The experimental–numerical comparison shows that the laboratory results are lower than numerical, while signs and orders of magnitude are the same. It is concluded that the results of the FEM analysis can be considered acceptabl…
Analysis of stability of axially moving orthotropic membranes and plates with a linear non-homogeneous tension profile
2011
Generation of programmable 3D optical vortex structures through devil’s vortex-lens arrays
2013
Different spatial distributions of optical vortices have been generated and characterized by implementing arrays of devil's vortex lenses in a reconfigurable spatial light modulator. A simple design procedure assigns the preferred position and topological charge value to each vortex in the structure, tuning the desired angular momentum. Distributions with charges and momenta of the opposite sign have been experimentally demonstrated. The angular velocity exhibited by the phase distribution around the focal plane has been visualized, showing an excellent agreement with the simulations. The practical limits of the method, with interest for applications involving particle transfer and manipula…
Minimally invasive plate fixation in femoral shaft fractures
1997
Bridge-plating with its advantages in terms of vascularity and bone healing is a well established procedure today in the treatment of comminuted femoral fractures. Bridge-plating means that the fracture site is not interfered with during the operative procedure. This paper introduces a surgical technique in which the plate is inserted through isolated proximal and distal incisions only, behind the vastus lateralis. Alignment is secured by the plates, the fracture site remains untouched, fixation and screw insertion is restricted to the proximal and distal main fragments. Longitudinal femoral fractures extending right into the trochanteric and or condylar areas are the main indication for mi…
A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates.
2004
OBJECTIVES To examine the biomechanical behavior of 2 techniques of double-plate osteosynthesis for fractures of the adult distal humerus using conventional reconstruction plates and locking compression plates. DESIGN Basic science study. SETTING Experimental in vitro study. PATIENTS/PARTICIPANTS Forty fresh-frozen human distal humeri specimens. INTERVENTION Four matched groups with 10 humeri each, median age 74 years (46-95), were created using similar bone mineral density values. Two standard configurations of double-plate osteosynthesis (dorsal or 90 degrees configuration) with either conventional reconstruction plates or locking compression plates were studied for biomechanical properti…
Locked Plate Fixation and Intramedullary Nailing for Proximal Humerus Fractures: A Biomechanical Evaluation
2005
Background Internal fixation of proximal humeral fractures is associated with a considerable secondary malalignment rate. Fixed-angle implants have been suggested to increase the stability of fixation. Methods The biomechanical properties of four different implants were tested. These included an internal fixator with semi-elastic properties (reference), the Synthes T-plate, a locked plate with rigid properties and a spiral blade locked intramedullary nail (PHN). These implants were assessed in twenty-four osteotomized pairs of human cadaveric humeri. Specimens were subjected to two-hundred cycles of axial loading and torque followed by load to failure. Results The PHN had greater axial stif…
The Surgery of Neglected Distal Humerus Fractures in Children and Adults
2008
The restoration of function after a neglected distal humerus fracture presents a formidable challenge to the surgeon because of both the complexity of the regional anatomy and the proximity of numerous neurovascular structures. Inadequate or unstable fixation, a failure to reposition the articular fragments anatomically, prolonged post-operative immobilization, or the development of soft-tissue complications will result in substantial disability for the patient. Complications after injuries affecting a child’s elbow are common due to understimating the severity of the injury on the native X-rays where the growth plates and cartilage structures can not be seen.
Stability of radial head and neck fractures: a biomechanical study of six fixation constructs with consideration of three locking plates.
2007
Open reduction and internal fixation of radial neck fractures can lead to secondary loss of reduction and nonunion due to insufficient stability. Nevertheless, there are only a few biomechanical studies about the stability achieved by different osteosynthesis constructs.Forty-eight formalin-fixed, human proximal radii were divided into 6 groups according to their bone density (measured by dual-energy x-ray absorptiometry). A 2.7-mm gap osteotomy was performed to simulate an unstable radial neck fracture, which was fixed with 3 nonlocking implants: a 2.4-mm T plate, a 2.4-mm blade plate, and 2.0-mm crossed screws, and 3 locking plates: a 2.0-mm LCP T plate, a 2.0-mm 6x2 grid plate, and a 2.0…
Inattentional deafness under dynamic musical conditions
2009
While inattentional blindness is a modern classic in attention and perception research, analogous phenomena of inattentional deafness are less well-known. In music, inattentional deafness has never been demonstrated under controlled experimental conditions, despite of indirect evidence for related effects. We tested inattentional deafness with real music in both musicians and non-musicians. Participants listened to the first 1’50” of Richard Strauss’ Thus Spake Zarathustra, with the experimental group having the task of counting the number of tympani beats and the control group just listening. The unexpected event was an e-guitar solo during the last 20s of this sequence. In Study 1, among …