Search results for "portable"
showing 10 items of 71 documents
Tecniche di Test Innovative per la Caratterizzazione di Memorie a Gate Flottante
L’affidabilità nella ritenzione dei dati memorizzati è una delle problematiche fondamentali delle memorie flash; esse vengono normalmente testate, in produzione con procedure specifiche implementate su ATE (Automated Test Equipments), per rilevare problemi di lettura, programmazione e cancellazione; vengono inoltre provate altre procedure per identificare possibili faults e per il corretto trimming dei parametri interni. Oggi, il testing classico con ATE è supportato dalle tecniche BIST (Built-In-Self-Test), tramite le quali si prevede in progetto, all’interno dei circuiti integrati, una parte di hardware e software supplementari per permettere l’auto-test (funzionale e/o parametrico), così…
Wireless battery chargers for portable applications: Design and test of a high-efficiency power receiver
2013
In this study, the authors present a 5 W wireless battery charger for handheld devices. Efficiency-related issues are addressed. A power receiver architecture which improves power conversion efficiency is proposed. Design hints are provided for further applications. Comparison with a conventional architecture is provided as well. Laboratory prototypes of both the proposed and the conventional architectures have been realised. Both prototypes are tested by using the same power transmitter to perform a valuable comparison. As shown by the experimental results, in the receiver side power conversion efficiency is increased up to 99% thanks to the proposed solution.
Combination of ozonation and photocatalysis for purification of aqueous effluents containing formic acid as probe pollutant and bromide ion
2014
The treatment by advanced oxidation processes (AOPs) of waters contaminated by organic pollutants and containing also innocuous bromide ions may generate bromate ions as a co-product. In the present work heterogeneous photocatalysis and ozonation have individually been applied and in combination (integrated process) to degrade the organic compounds in water containing also bromide anions. The results show that: i) the sole photocatalysis does not produce bromate ions and in the case of its presence, it is able to reduce bromate to innocuous bromide ions; ii) the integration of photocatalysis and ozonation synergistically enhances the oxidation capabilities; and iii) in the integrated proces…
Analysis of Sagunto Ibero-Roman votive bronze statuettes by portable X-ray fluorescence
2019
Abstract The main objective of this work was the study of chemical composition of an important collection of Ibero-Roman votive bronze statuettes exposed in the Archaeological Museum of Sagunto (Spain). Precision and accuracy of the measurements were obtained developing a proper analytical method, also avoiding any possible damage to the studied objects using a portable energy dispersive X- ray fluorescence system. Principal Components Analysis (PCA) to discriminate between groups based on ratios Fe/Cu, Pb/Cu, Sn/Cu, Ag/Cu, Ni/Cu and Impurities/Cu were employed to observe differences between the used smelting, manufacturing processes and raw materials. The characterisation of bronze statuet…
Anaerobic removal of 1-methoxy-2-propanol under ambient temperature in an EGSB reactor
2015
Two laboratory-scale expanded granular sludge bed (EGSB) reactors were operated at 18 and 25 °C, respectively, for the treatment of synthetic wastewater composed of ethanol and 1-methoxy-2-propanol (M2P) in a mass ratio of 4:1. Reactors were operated first with continuous wastewater supply and after with discontinuous substrate supply (5 days a week, 16 h a day) to simulate shift working conditions. Under continuous wastewater supply chemical oxygen demand (COD), removal efficiency higher than 95 % was achieved at the end of the trial applying organic loading rates (OLR) of 29 and 43 kg COD m(-3) day(-1) at 18 and 25 °C; thus, corresponding to M2P OLR of 6.4 and 9.3 kg COD m(-3) day(-1), re…
Study on a photocatalytic membrane reactor for water purification
2000
Abstract Some results obtained in a photocatalytic membrane reactor, to be used for degradation of toxic organic species dissolved in water, are reported. The catalyst, TiO 2 P25 Degussa, was immobilised by means of a flat sheet polymeric membrane and 4-Nitrophenol (4-NP) was used as a model molecule to evaluate the reactor performance. A preliminary investigation of the stability, under UV irradiation, of some eligible polymeric membranes was carried out by using scanning electron microscopy (SEM), optical microscopy (OM), determinations of water permeation flux (WPF) and total organic carbon (TOC). These tests showed that commercial membranes made of fluoride + PP (FS 50 PP-Dow), polysulp…
Low invasive multisensor acquisition system for real-time monitoring of cardiovascular and respiratory parameters
2020
The recent advances in multiparametric monitoring of biosignals and management of big data prompt for the development of devices and techniques for the extraction of indicators with physiological relevance. In this context, we have designed and realized a portable electronic system, equipped with simple biomedical sensors, able to synchronously record multiple electrocardiographic (ECG), photoplethysmographic (PPG) and breathing signals, for carrying out a non-invasive monitoring of several cardiovascular parameters. In this work, we show the results of preliminary measurements performed following a specific physiological protocol (i.e., deep breathing with 10 s per cycle). The system allow…
Portability in analytical chemistry: a green and democratic way for sustainability
2019
International audience; Recent advances in portability of analytical equipment have been considered to enlighten the advantages offered by portable instrumentation on greening the analytical methods. Their use drastically reduces sampling, sample stockage, and transport, thus avoiding environmental side effects and risks, also improving decision-making. The fact that portable instrumentation is, in general, less expensive than bench instruments and apparatuses makes also available the analytical tools for extended sectors of the population, thus making accessible the advantages derived from analytical methods. The role of sensor technology and portable miniaturized systems has been consider…
Portable microwave assisted extraction: An original concept for green analytical chemistry.
2013
International audience; This paper describes a portable microwave assisted extraction apparatus (PMAE) for extraction of bioac-tive compounds especially essential oils and aromas directly in a crop or in a forest. The developed procedure, based on the concept of green analytical chemistry, is appropriate to obtain direct in-field information about the level of essential oils in natural samples and to illustrate green chemical lesson and research. The efficiency of this experiment was validated for the extraction of essential oil of rosemary directly in a crop and allows obtaining a quantitative information on the content of essential oil, which was similar to that obtained by conventional m…
Portable non invasive analyses for Cultural Heritage
2014
The requirements that the scientific analyses for Cultural Heritage must have are: nondestructive and noninvasive, multielemental, sensitive, reliable and sufficiently rapid, able to carry out measurements in situ on objects of all types, and to deduce information practically on-line. Among the techniques that fulfill these requirements we find: multispectral imaging, portable EDXRF, Raman and UV-VIS-NIR spectrometry. In this paper we are going to show some cases in which it will appear clear the necessity of the correct order with which applying the non invasive techniques and what data of each of them it is necessary to understand in situ to obtain the maximum of the subsequent scientific…