Search results for "preparation"
showing 10 items of 939 documents
Phytochemical profile and bioactivity of traditional ayurvedic decoctions and hydro-alcoholic macerations of Boerhaavia diffusa L. and Curculigo orch…
2015
Decoctions (DECs) and hydro-alcoholic extracts (HEs) prepared from roots of Boerhaavia diffusa L. (Nyctaginaceae) and Curculigo orchioides Gaertn. (Hypoxidaceae) were phytochemically characterised by HPLC-DAD and profiled for their antioxidant, antigenotoxic and cytotoxic activities. B. diffusa DEC was rich in ferulic acid and vanillin, while the HE also contained boeravinone B and eupalitin. Both C. orchioides HE and DEC displayed the main occurrence of orcinol-β-d-glucoside and curculigoside A. Antioxidant activity was assayed through spectrophotometric DPPH, ABTS and β-carotene bleaching test, and using (HP)TLC bioautographic strategies. For both crude drugs, HE was the best performing p…
Supported liquid membrane extraction with single hollow fiber for the analysis of fluoroquinolones from environmental surface water samples
2010
Abstract In this work, the simple analytical method for the determination of four fluoroquinolone antibiotics: ciprofloxacin, enrofloxacin, norfloxacin and danofloxacin, in environmental surface water samples is described. Sample pretreatment step was performed by the application of a technique based on supported liquid membrane extraction with the configuration of single hollow fiber (HF-SLM). The HPLC system with diode array detection was used for final analysis of studied analytes. Various parameters affecting the extraction efficiency during HF-SLM enrichment, such as type of membrane diluent, pH of donor (sample) and acceptor phases, as well as an enrichment time and salt content of sa…
IMI – Oral biopharmaceutics tools project – Evaluation of bottom-up PBPK prediction success part 4: Prediction accuracy and software comparisons with…
2020
Oral drug absorption is a complex process depending on many factors, including the physicochemical properties of the drug, formulation characteristics and their interplay with gastrointestinal physiology and biology. Physiological-based pharmacokinetic (PBPK) models integrate all available information on gastro-intestinal system with drug and formulation data to predict oral drug absorption. The latter together with in vitro-in vivo extrapolation and other preclinical data on drug disposition can be used to predict plasma concentration-time profiles in silico. Despite recent successes of PBPK in many areas of drug development, an improvement in their utility for evaluating oral absorption i…
Determination of quality parameters of beers by the use of attenuated total reflectance-Fourier transform infrared spectroscopy
2005
Abstract The estimation of important quality parameters of beers, such as original and real extracts and alcohol content, has been evaluated by attenuated total reflectance-Fourier transform infrared spectroscopy (ATR-FTIR) using a partial least square (PLS) calibration approach. Two sample populations, one consisting of 24 samples and other of 21 samples, obtained from the Spanish market and covering different types of beer were used. The first set was used for building and validating the model, whereas the second, measured 6 months after, was used for evaluating its robustness. The spectral range and the size of the calibration set and its suitability for building the PLS model have been …
Cutting efficiency of heat-treated nickel-titanium single-file systems at different incidence angles.
2020
Cutting efficiency of Reciproc R25 (REC) and Reciproc blue R25 (REB) at different inclinations was evaluated. Sixty new files were tested at 90°, 70° and 45° of inclination in relation to the sample (n = 10), using a customised machine. All files were activated in reciprocation against standardised gypsum blocks for 120 s. Cutting efficiency was determined by measuring the block weight loss with an analytical balance and measuring the length of the block surface cut using a digital calliper. Data were statistically analysed (two-way ANOVA, Bonferroni t-test) with the significance level set at P < 0.05. There was no difference for REC among the tested angles. REB had no statistical differenc…
Length of endodontic files measured in digital radiographs with and without noise-suppression filters: an ex-vivo study
2011
The aim of this study is to evaluate if theoretically possible edge shifts induced by noise-suppression filters potentially occur on objects found in digital radiographs. Most manufacturers carry out noise-suppression filtering of their images before they are displayed to the user. It is not usually possible for the user to disrupt the function of the filters. The use of these filters can lead to deletion of small image structures.K-files (ISO size 06, 08, 10 and 15) were placed in the root canals of 6 human teeth located in cadaver jaw segments. File tip positions were measured on original and filtered digital images by three observers. The file position was marked on each filtered image a…
Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization
2010
Aim: The aim of the present study was to electrochemically evaluate corrosion resistance of RaCe and Mtwo files after repeated sterilization and preparation procedures. Study Design: A total of 450 rotary files were used. In the working groups, 72 files from each file type were distributed into 4 groups. RaCe and Mtwo files were used to prepare one root canal of the mesial root of extracted human mandibular first molars. The procedure was repeated to prepare 2 to 8 canals. The following irrigation solutions were used: group 1, RaCe files with 2.5% NaOCl; group 2, RaCe files with normal saline; group 3, Mtwo files with 2.5% NaOCl; and group 4, Mtwo files with normal saline in the manner desc…
Survival rates of a lithium disilicate-based core ceramic for three-unit esthetic fixed partial dentures: a 10-year prospective study.
2013
Purpose The aim of this prospective study was to evaluate the clinical efficacy and long-term survival rate of three-unit fixed partial dentures (FPDs) made from lithium disilicate-based core ceramic. Materials and methods Twenty-one three-unit FPDs were placed in 19 patients to replace single lost teeth in the esthetic area, following a study protocol that took clinical, esthetic, and radiologic aspects into consideration. Each case was reviewed at 1 week following placement, at 6 months, and then annually for 10 years. Statistical analysis was performed using Kaplan-Meier survival analysis. Results Out of the 19 patients, 14.3% presented reversible postoperative sensitivity. Recession was…
Shaping ability of nickel-titanium rotary instruments in simulated S-shaped root canals.
2009
Objective The aim of this study was to compare the shaping ability of 4 nickel-titanium rotary techniques and 1 hand technique in simulated S-shaped curved root canals. Study design Seventy-five simulated double-curved resin root canals were divided into 5 groups (n = 15). The canals were compared at 12 different levels and at 3 different times: before preparation and after preparation to master apical 25 and 35. Data were statistically analyzed by performing 2-by-2 comparisons with the Tukey parametric test of variance analysis using a confidence interval of 95%. Results All of the 75 resin blocks presented transportation of the root canals by transforming the apical curvature into a strai…
Addition of thiourea and hydrochloric acid: Accurate nanogram level analysis of mercury in humic-rich natural waters by inductively coupled plasma ma…
2020
Abstract An analytical method was developed for the direct determination of total mercury in natural waters at low ng L−1 level by inductively coupled plasma mass spectrometry (ICP-MS). The presented method overcomes previously observed problems relating to poor spike recoveries by adding 0.12% thiourea in addition to 3% HCl to all samples and standards. The sample preparation is fast and easy to perform by the developed method since it requires only the addition of HCl and thiourea to the water samples. A very low instrument detection limit (0.4 ng L−1) was obtained without time-consuming preconcentration procedures. The accuracy and precision of the developed method were found excellent b…