Search results for "presbyopia"

showing 10 items of 51 documents

Visual performance of two simultaneous vision multifocal contact lenses

2012

Purpose To evaluate and compare the visual performance of two simultaneous vision multifocal contact lenses (CLs). Methods In this cross-over study design 20 presbyopic subjects were fitted with two different simultaneous vision multifocal CLs (the PureVision Multifocal Low Add and Acuvue Oasys for Presbyopia) in random order. After 1 month, binocular distance visual acuity (BDVA) under photopic (85 cd/m2) and mesopic (3 cd/m2) conditions, binocular near visual acuity (BNVA), binocular distance contrast sensitivity function (CSF) under photopic and mesopic conditions, binocular near CSF and defocus curve were measured. Subjects were then refitted with the alternative correction and the proc…

AdultMaleVisual acuitygenetic structuresContact LensesMesopic visionmedia_common.quotation_subjectVisual Acuitylaw.inventionContrast SensitivitylawmedicineHumansContrast (vision)media_commonVision BinocularCross-Over Studiesbusiness.industryIntermediate distanceBoth lensesPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologyOptometryFemalemedicine.symptombusinessOptometryPhotopic visionOphthalmic and Physiological Optics
researchProduct

Visual Performance of Four Simultaneous-Image Multifocal Contact Lenses Under Dim and Glare Conditions

2014

To assess and compare the effects of four simultaneous-image multifocal contact lenses (SIMCLs), and those with distant-vision-only contact lenses on visual performance in early presbyopes, under dim conditions, including the effects of induced glare.In this double-masked crossover study design, 28 presbyopic subjects aged 40 to 46 years were included. All participants were fitted with the four different SIMCLs (Air Optix Aqua Multifocal [AOAM; Alcon], PureVision Multifocal [PM; BauschLomb], Acuvue Oasys for Presbyopia [AOP; JohnsonJohnson Vision], and Biofinity Multifocal [BM; CooperVision]) and with monofocal contact lenses (Air Optix Aqua, Alcon). After 1 month of daily contact lens wear…

AdultMalegenetic structuresContact LensesComputer scienceCrossoverVisual AcuityGlareContrast SensitivityOpticsDouble-Blind MethodHumansLightingAnalysis of VarianceCross-Over Studiesbusiness.industryGlare (vision)PresbyopiaMiddle AgedCrossover studyeye diseasesOphthalmologyOptometryFemalesense organsbusinessEye & Contact Lens: Science & Clinical Practice
researchProduct

Changes in accommodative responses with multifocal contact lenses: a pilot study.

2011

Our aim was to evaluate induced changes in pupil and accommodative response for different accommodative stimuli with three different multifocal contact lenses (CLs). Accommodative and pupil responses with three aspheric multifocal CLs of simultaneous focus center near (PureVision Low Add, PureVision High Add and Focus Progressives) for two accommodative stimuli of -2.5 and -4.00 D were recorded in 10 young subjects. Accommodative response, peak velocity, and time constant of accommodation and pupil constriction were assessed. The measurements were evaluated in all the participants with distance-single vision CLs and with the three multifocal CLs. The monocular measurements were performed in…

AdultMalemedicine.medical_specialtyAccommodative responsegenetic structuresContact LensesVisual AcuityPilot ProjectsRefraction OcularPupillaw.inventionOpticsCLs upper limitslawOphthalmologymedicineHumansMathematicsMonocularCross-Over Studiesbusiness.industryAccommodation OcularPupilPresbyopiaEquipment Designmedicine.diseaseRefractive Errorseye diseasesLens (optics)OphthalmologyTreatment OutcomePeak velocityOftalmologíaFemalebusinessAccommodationOptometryFollow-Up StudiesOptometry and vision science : official publication of the American Academy of Optometry
researchProduct

Multisectorial changes in the ciliary muscle during accommodation measured with high-resolution optical coherence tomography

2019

ABSTRACT Purpose: To measure changes in the anterior ciliary muscle during accommodation at the nasal, superior, temporal, and inferior sectors by means of an anterior chamber optical coherence tomographer, and correlate them with vergence changes. Methods: Twenty-four subjects with healthy, phakic eyes, whose mean age was 27.1 ± 8.9 years, underwent measurement with an anterior chamber optical coherence tomographer. The anterior ciliary muscle was measured at the nasal, temporal, superior, and inferior sectors for 0, -1, -2, and -3 D of vergence. A linear model was used to assess the correlation of each eye parameter with the accommodative demand. Results: The anterior ciliary muscle area …

AdultMalemedicine.medical_specialtyBiometryHigh resolutionVergenceStatistics NonparametricYoung Adult03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyOptical coherence tomographyReference ValuesOphthalmologyHumansMedicineTomographyMúsculo ciliarBiometriaAnalysis of Variancemedicine.diagnostic_testbusiness.industryCiliary BodyOptical coherenceBiomechanicsAccommodation OcularPresbyopiaGeneral MedicinePresbyopiamedicine.diseaseBiomechanical PhenomenaCiliary muscleOphthalmologyCiliary musclelcsh:RE1-994Acomodação ocularTomografia de coerência ópticaAccommodation ocularLinear Models030221 ophthalmology & optometryPositive relationshipFemalesense organsPresbiopiabusinessAccommodationTomography Optical CoherenceArquivos Brasileiros de Oftalmologia
researchProduct

Visual performance with simultaneous vision multifocal contact lenses.

2011

Purpose:  The aim was to assess visual performance after PureVision high addition multifocal contact lens (PM) fitting through contrast sensitivity measured under different illumination levels for both distance and near. Methods:  In a cross-over study, 20 presbyopic patients were randomly assigned to PM or spectacles. Near contrast sensitivity was measured with the Vistech VCTS 6500 system. Distance contrast sensitivity and distance visual acuity (VA) were measured with the Functional Vision Analyser under photopic (85 cd/m2) and mesopic (3.0 cd/m2) conditions, the latter also under two levels of induced glare: 1.0 lux and 28 lux. Near VA was measured by logMAR charts under approximately 8…

Adultmedicine.medical_specialtyDistance visual acuitygenetic structuresMesopic visionContact Lensesmedia_common.quotation_subjectVisual AcuityContrast SensitivityOpticsOphthalmologymedicineContrast (vision)Humansmedia_commonMathematicsMonocularCross-Over Studiesbusiness.industryGlare (vision)Accommodation OcularPresbyopiaEquipment DesignPresbyopiaMiddle Agedmedicine.diseaseeye diseasesContact lensOphthalmologyTreatment OutcomebusinessOptometryPhotopic visionFollow-Up StudiesClinicalexperimental optometry
researchProduct

Accommodative intraocular lenses: current status

2005

Purpose of review The possibility of using a monofocal IOL with accommodative ability allows refractive cataract surgery with a clearly decreased potential of photic phenomena. Three IOLs of different designs and materials have demonstrated accommodative ability, but the degree of accommodative amplitude has been reported to different extents and variabilities. The plate-haptic CrystaLens has a hinged design that might permit forward movement of the optic as a result of pressure changes in the vitreous cavity. The 1CU has modified haptics that bend in the bag as the lens capsule contracts, which are supposed to cause anterior displacement of the lens optic. With the dual-optic one-piece Syn…

Anterior lensgenetic structuresmedicine.medical_treatmentCataract ExtractionProsthesis Designlaw.inventionLens Implantation IntraocularlawmedicineHumansLenses IntraocularLens capsulebusiness.industryAccommodation OcularPresbyopiaGeneral MedicinePresbyopiaCataract surgerymedicine.diseaseeye diseasesLens (optics)OphthalmologyIntraocular lensesCapsular bagOptometrysense organsbusinessAccommodationCurrent Opinion in Ophthalmology
researchProduct

Proposal of a new diffractive corneal inlay to improve near vision in a presbyopic eye

2020

[EN] A new class of diffraction-based corneal inlays for treatment of presbyopia is described. The inlay is intended to achieve an improvement of the near focus quality over previous designs. Our proposal is a two-zone hybrid device with separated amplitude and phase areas having a central aperture and no refractive power. An array of micro-holes is distributed on the surface of the inlay conforming a binary photon sieve. In this way, the central hole of the disk contributes to the zero order of diffraction, and the light diffracted by the micro-holes in the peripheral photon sieve produces a real focus for near vision. We employed ray-tracing software to study the performance of the new in…

DiffractionApertureComputer scienceVisual AcuityOptical powerRefraction OcularDiffraction efficiencyModels Biological01 natural sciencesCorneaCorneal Transplantation010309 opticsOpticsOptical transfer function0103 physical sciencesMyopiamedicine03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edadesHumansComputer SimulationElectrical and Electronic EngineeringEngineering (miscellaneous)Vision BinocularInlaymedicine.diagnostic_testbusiness.industryCorneal TopographyPresbyopiaPresbyopiaModels Theoreticalmedicine.diseaseCorneal topographyCorneal inlayAtomic and Molecular Physics and OpticsPhoton sieveIntraocular lensesFISICA APLICADAbusinessOrbital ImplantsApplied Optics
researchProduct

Sintonika un presbiopija

2017

Pēdējos gados sintonika kā metode ir kļuvusi pieejamāka un pielietojamāka redzes uztveres optometristu vidū. Metodi pielieto, lai sabalansētu simpātisko un parasimpātisko nervu sistēmu saskaņotu darbību, pielietojot dažādu krāsu filtrus. Darba mērķis bija novērtēt sintonikā pielietoto filtru iespējas sākotnējas presbiopijas ārstēšanai. Darbā tiek analizēti pacientu dati par sintonikas iedarbības efektivitāti sākotnējās presbiopijas gadījumos. Redzes asums, bet novērtējot to bez tuvuma aditīva, akomodācijas amplitūda un zīlītes α-ω mērījumi uzrāda statistiski nozīmīgi atšķirīgus rezultātus pirms un pēc sintonikas pielietošanas. Ietekme ir arī uz formas redzes funkcionālo lauku, kā arī uz fun…

FiltersFizikaPresbyopiaVisual trainingPhototherapySyntonic
researchProduct

Visual and Refractive Outcomes in Hyperopic Pseudophakic Patients Implanted with the Acri.LISA 366D Multifocal Intraocular Lens

2009

Our purpose was to assess the visual quality after bilateral implantation of the Acri.LISA 366D intraocular lens (IOL; Carl Zeiss Meditec, Jena, Germany) in patients with hyperopia. We did a prospective and nonrandomized study. One hundred and seventy eyes of 85 patients had bilateral implantation of the Acri.LISA 366D IOL. The patients were divided into 2 groups: low to moderate hyperopia (IOL power, 21 to 24.5 diopters [D]) and high hyperopia (IOL power, 25 to 36 D). Monocular and binocular best spectacle-corrected visual acuity (BSCVA), best distance-corrected near visual acuity (BCNVA), binocular best distance-corrected intermediate visual acuity (VA), and distance contrast sensitivity …

MaleRefractive errormedicine.medical_specialtyVisual acuityPseudophakiagenetic structuresMesopic visionmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensContrast SensitivityVision disorderTonometry OcularLens Implantation IntraocularOphthalmologymedicineHumansProspective StudiesIntraocular PressureDioptreLenses IntraocularVision BinocularPhacoemulsificationbusiness.industryHipermetropíaPresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOftalmologíaOptometryFemalesense organsmedicine.symptombusinessPhotopic visionAmerican Journal of Ophthalmology
researchProduct

Effect of multizone refractive multifocal contact lenses on the Cirrus HD OCT retinal measurements

2011

Background Simultaneous vision multifocal contact lenses are widely used to alleviate the symptoms of presbyopia. These contact lenses create simultaneous retinal images due to the incoming light distribution being divided into two or more focuses. Our aim was to evaluate whether the multizone refractive multifocal contact lenses affect the measurements of the retinal nerve fibre layer (RNFL) and macular thickness using optical coherence tomography (OCT). Methods In this cross-over study, 30 eyes of 30 subjects with a mean age of 50.42 ± 7.82 years were fitted with multizone refractive multifocal contact lenses. Using the RNFL Thickness Analysis mode of the Cirrus HD (Carl Zeiss, Meditec, D…

MaleRetinal Ganglion Cellsmedicine.medical_specialtyMaterials sciencegenetic structuresContact LensesVisual AcuityRefraction Ocularchemistry.chemical_compoundNerve FibersOpticsOptical coherence tomographySignal strengthOphthalmologymedicineHumansÓpticaCross-Over Studiesmedicine.diagnostic_testbusiness.industryRetinalEquipment DesignPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseRefractioneye diseasesContact lensOphthalmologychemistryOftalmologíaFemaleCirrussense organsTomographybusinessTomography Optical CoherenceOptometryClinical and Experimental Optometry
researchProduct