The Efficacy of Powered Oscillating Heads vs. Powered Sonic Action Heads Toothbrushes to Maintain Periodontal and Peri-Implant Health: A Narrative Re…
2021
Objectives: To compare the efficacy of rotating-oscillating heads (ORHs) VS sonic action heads (SAHs) powered toothbrushes on plaque accumulation and gingival inflammation. Methods: An electronic (MEDLINE, Embase, Inspec, PQ SciTech and BIOSIS) and a complementary manual search were made to detect eligible studies. RCTs meeting the following criteria were included: final timepoint longer than 15 days; year of publication after 2000; patients without orthodontic appliances or severe systemic/psychiatric diseases. Studies comparing two or more different types of sonic/roto-oscillating toothbrushes were excluded. Selection of articles, extraction of data, and assessment of quality were made in…
Multilayer capsules: a promising microencapsulation system for transplantation of pancreatic islets
2001
In 1980, Lim and Sun introduced a microcapsule coated with an alginate/polylysine complex for encapsulation of pancreatic islets. Characteristic to this type of capsule is, that it consists of a plain membrane which is formed during a single procedural step. With such a simple process it is difficult to obtain instantly a membrane optimized with respect to all the properties requested for islet transplantation. To overcome these difficulties, it is recommended to build up the membrane in several consecutive steps, each optimized for a certain property. In this study, we have analysed such a multilayer microcapsule for the encapsulation of pancreatic islets. Therefore, empty and islet contai…
The Foreign Body Response to an Implantable Therapeutic Reservoir in a Diabetic Rodent Model
2021
Advancements in type 1 diabetes mellitus treatments have vastly improved in recent years. The move toward a bioartificial pancreas and other fully implantable systems could help restore patient's glycemic control. However, the long-term success of implantable medical devices is often hindered by the foreign body response. Fibrous encapsulation "walls off" the implant to the surrounding tissue, impairing its functionality. In this study we aim to examine how streptozotocin-induced diabetes affects fibrous capsule formation and composition surrounding implantable drug delivery devices following subcutaneous implantation in a rodent model. After 2 weeks of implantation, the fibrous capsule sur…
A 10-Year Cone Beam Computerized Tomography Observation of the Buccal Bony Wall of an Immediately Placed Implant at the Anterior Maxilla: A Case Repo…
2017
Since the introduction of immediate implant placements, the buccal bony wall has been a major consideration for success due to its correlation with soft tissue contour and color. This report presents the stability of the buccal wall thickness of an immediately placed implant at the anterior maxilla over 10 years. Although the width of the buccal wall decreased at the 2-year post-op follow-up, it remained stable afterward according to cone beam computerized tomography (CBCT) scans. Hence, this report suggests that ensuring adequate bony wall thickness with bone augmentation and fixture position may promise the longevity of the buccal bony wall and surrounding soft tissue in an immediate impl…
Effect of electron-beam irradiation on structure of ultra high molecular weight polyethylene used in medical implants
2004
Określono wpływ napromieniania strumieniem elektronów dawką równoważną stosowanej w praktyce podczas sterylizacji radiacyjnej endoprotez chirurgicznych (26 kGy) oraz dwukrotnie większą (2 . 26 kGy) na zmianę struktury PE-UHMW o nazwie handlowej „,Chirulen 1120”' (tabela 1) służącego do otrzymywania panewek endoprotez biodrowych. Metodą FT-IR zbadano zmiany strukturalne polimeru, stwierdzając głównie występowanie skutków jego utlenienia (wzrost udziału grup karbonylowych typu ketonowego, estrowego i nadestrowego, grup hydroksylowych oraz winylowych) (rys. 1). Metodą GPC stwierdzono, że napromienianie powoduje także częściową degradację makrocząsteczek (zmniejszenie ciężaru cząsteczkowego o j…
Prosthetic strap system for simplified ventral hernia repair. Its results in a porcine experimental model.
2010
Abstract: Introduction Aiming to achieve a simplified ventral hernia repair, a proprietary shaped mesh was experimentally tested in the porcine model. The mesh is structured with a large central body and radiating straps. The friction of the straps passing through the tissues are hypothesized to be adequate to maintain the mesh in place during tissue ingrowth, avoiding classic point fixation while ensuring a wide coverage of the abdomen. Methods The mesh, having 6 radial straps, was placed using a sublay preperitoneal technique in 4 pigs. All straps were passed laterally through the abdominal wall and exteriorized from the skin. The straps were trimmed at the level of the skin, allowing the…
Nickel release after implantation of the Amplatzer occluder.
2003
Background Transcatheter closure of atrial septal defects is a new and less traumatic technique than open heart surgery. In recent years, patients with a patent foramen ovale sustaining potential paradoxical embolism have also become candidates for interventional closure devices. One of the more popular occluding devices is the Amplatzer septal occluder, which, like many other occluders, is made of nitinol. Nitinol-based alloys are widely used in medical products, for example, in orthopedics and orthodontics. However, the clinical use of nitinol, which contains 55% nickel, is still controversial because of concerns about its biocompatibility. Therefore, we examined the systemic nickel relea…
Spring constants of capsular tension rings.
2004
Purpose To determine the spring constants of several types of capsular tension rings (CTRs). Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Fourteen models of CTRs provided by 9 companies were tested; all were 11.0 mm in diameter. The CTRs were positioned in a special retainer of a material-testing machine and compressed at a constant speed of 10.0 mm per minute. The distance and force values were recorded, and each CTR model was tested 3 times using a new specimen each time. The resulting measurements were used to calculate a mean spring constant for each CTR model. Results All tested CTRs showed linear proportionality between force and compress…
A diagnostic trap for the dermatopathologist: granulomatous reactions from cutaneous microimplants for cosmetic purposes.
2007
We present a case of late granulomatous reactions from silicone that first appeared in a site different from that of the injection causing an incorrect diagnosis of liposarcoma in the beginning. The histological picture was a cystic-macrophagic granuloma in both the injection site (upper lip) and the migrating site (paranasal regions). We think that the foreign body has undergone an antigravity migration from the upper lip to the right paranasal region. To our knowledge, such a phenomenon has not been yet reported in literature.
Biomechanical and histological evaluation of abdominal wall compliance with intraperitoneal onlay mesh implants in rabbits: A comparison of six diffe…
2012
Abstract Background An ideal prosthetic mesh for incisional hernia repair should mimic the anisotropic compliance of the abdominal wall, and at lower loads should exhibit higher distensibility without impairment of safety at higher loads. This study evaluated the biomechanical properties of six meshes in a rabbit model. Methods New Zealand white rabbits were used for this study. Two meshes of the same brand (Ethicon Physiomesh™, Bard Composix ® L/P, Gore Dualmesh ® , Bard Sepramesh ® , Ethicon Proceed ® or Parietex™ Composite) were implanted into each animal for assessment of intra-abdominal hernia repair, with a total of ten meshes per group. Twelve weeks after implantation, the abdominal …