Influence of the patients sex, type of dental prosthesis and antagonist on residual bone resorption at the level of the premaxilla

2011

Objectives: To analyze the height and width of the ridge at the level of the premaxilla in edentulous patients, evaluating whether the sex of the patient, type of prosthetic rehabilitation and antagonist have an influence. Material and Method: We randomly selected a total of 89 patients, having an average age of 66.21 years old. A total of 308 measurements were made, all of them at the level of the premaxilla, in the intercanine area. As dependent variables, we analyzed the patients’ sex, age and the antagonist: removable (dental) prostheses (RP), fixed (dental) prostheses (FD), natural dentition (ND). As independent variables, we measured the height and residual width in sagittal sections …

MalePremaxillamedicine.medical_treatmentDentistryProsthesisBone resorptionDental ProsthesisSex FactorsClinical and Experimental DentistryMaxillamedicineHumansBone ResorptionGeneral DentistryAgedRetrospective StudiesDentitionbusiness.industryDental prosthesisAge FactorsAntagonistMiddle Aged:CIENCIAS MÉDICAS [UNESCO]Sagittal planemedicine.anatomical_structureOtorhinolaryngologyMaxillaUNESCO::CIENCIAS MÉDICASResearch-ArticleFemaleSurgerybusinessMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Non-sutureless minimally invasive aortic valve replacement: mini-sternotomy versus mini-thoracotomy: a series of 1130 patients

2016

Objectives Aortic valve replacement through conventional sternotomy still represents the gold-standard surgical approach for aortic valve disease. However, given the increasing number of patients with comorbidities, strategies that can improve operative results are always sought. Minimally invasive aortic valve surgery, although related to a steep learning curve, might be associated with improved postoperative outcomes. The main aim of this study was to assess whether significant differences exist in terms of operative and early results between a mini-sternotomy and a right mini-thoracotomy approach for isolated aortic valve replacement without sutureless technologies. Methods This is an ob…

MalePulmonary and Respiratory MedicineAortic valveAortic valve replacement • Exposure • Incision • Minimally invasive surgery • Surgery • Techniquemedicine.medical_specialtymedicine.medical_treatmentHeart Valve Diseases030204 cardiovascular system & hematologylaw.invention03 medical and health sciences0302 clinical medicineAortic valve replacementlawmedicineCardiopulmonary bypassHumansMinimally Invasive Surgical ProceduresThoracotomyAgedRetrospective StudiesHeart Valve Prosthesis Implantationbusiness.industrySuture TechniquesAortic valve disorderRetrospective cohort studymedicine.diseaseSternotomySurgerymedicine.anatomical_structureThoracotomy030228 respiratory systemAortic ValveHeart Valve ProsthesisAortic valve surgeryFemaleSurgeryObservational studyCardiology and Cardiovascular Medicinebusiness
researchProduct

Adjunct Perfusion Branch for Reduction of Spinal Cord Ischemia in the Endovascular Repair of Thoracoabdominal Aortic Aneurysms

2017

Background To analyze utilization of a perfusion branch for temporary sac perfusion to reduce the spinal cord ischemia (SCI) in the endovascular repair of thoracoabdominal aortic aneurysms (TAAAs). Methods Between January 2012 and August 2016, 30 patients (18, men; median age 72 years) were treated for TAAAs with total endovascular repair using customized branched/fenestrated endografts in our institution. The median aneurysm size was 6.6 cm. Types of TAAA were: type I, 9 (30%), type II, 5 (16.6%), type III, 4 (13.3%), type IV, 6 (20%), and type V, 6 (20%). Ten patients received a perfusion branch to create an intentional endoleak, which was occluded with vascular plugs in mean interval ti…

MalePulmonary and Respiratory Medicinemedicine.medical_specialtyMean arterial pressureTime FactorsAortographyComputed Tomography Angiography030204 cardiovascular system & hematologyAortographyBlood Vessel Prosthesis Implantation03 medical and health sciencesAortic aneurysm0302 clinical medicineAneurysmRisk FactorsHumansMedicineArterial PressureHospital MortalityAgedComputed tomography angiographyAged 80 and overAortic Aneurysm Thoracicmedicine.diagnostic_testSpinal Cord Ischemiabusiness.industryEndovascular ProceduresMiddle Agedmedicine.diseaseSurgeryPerfusionTreatment OutcomeBlood pressureSpinal CordRegional Blood FlowCardiothoracic surgeryFeasibility StudiesFemaleSurgeryCardiology and Cardiovascular MedicinebusinessPerfusion030217 neurology & neurosurgeryThe Thoracic and Cardiovascular Surgeon
researchProduct

Endovascular treatment of large and wide aortic neck: case report and literature review

2017

Large (24–34 mm) and wide (≥35 mm) aortic necks are a contraindication to endovascular aneurysm repair (EVAR). A 63-year-old man, unfit for conventional surgery, presented a 79 mm abdominal aortic aneurysm with 36.5 mm aortic neck and a 62 mm right common iliac artery aneurysm. He was treated endovascularly with standard commercially available stent-graft using the so-called ‘funnel technique’; by placing a thoracic stent-graft inside a bifurcated device to achieve proximal sealing. The completion angiography and the 6 months follow-up with computed tomography showed no stent-graft migration, limb occlusion or endoleak. The literature review reported 179 cases of large aortic neck managed w…

MalePulmonary and Respiratory Medicinemedicine.medical_specialtyTime FactorsEndoleakTime Factormedicine.medical_treatmentRight Common Iliac Artery030204 cardiovascular system & hematologyEndovascular aneurysm repairSettore MED/22 - Chirurgia Vascolare030218 nuclear medicine & medical imaging03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicineAneurysmOcclusionmedicineStentHumanscardiovascular diseasesComplications; Endoleak; Funnel technique; Large neck; Migration; Aortic Aneurysm Abdominal; Blood Vessel Prosthesis Implantation; Endovascular Procedures; Humans; Male; Middle Aged; Time Factors; Tomography X-Ray Computed; Stents; Surgery; Pulmonary and Respiratory Medicine; Cardiology and Cardiovascular MedicineContraindicationMigrationEndovascular Proceduremedicine.diagnostic_testLarge neckbusiness.industryEndovascular ProceduresGeneral MedicineMiddle Agedmedicine.diseaseAbdominal aortic aneurysmSurgerysurgical procedures operativeAngiographycardiovascular systemStentsSurgeryAortic neckbusinessFunnel techniqueTomography X-Ray ComputedCardiology and Cardiovascular MedicineComplicationAortic Aneurysm AbdominalHuman
researchProduct

Outcome after surgery for acute aortic dissection type A in patients over 70 years: data analysis from the German Registry for Acute Aortic Dissectio…

2010

Objective: The number of elderly patients undergoing emergency surgery for acute aortic dissection type A (AADA) is rising. Published results report a higher risk for thesepatients comparedwith younger patients. The aim of our study wasto analyse the surgicaloutcomeof these patients and to identify those at risk. Methods: Between July 2006 and June 2009, 44 centres participating in the German Registry for Acute Aortic Dissection Type A (GERAADA) reported a total of 1558 patients. As many as 381 patients were between 70 and 80 years of age (septuagenarians), while 83 patients were 80 years and older (octogenarians). We compared the clinical features and events occurring 30 days after surgery…

MalePulmonary and Respiratory Medicinemedicine.medical_specialtylaw.inventionBlood Vessel Prosthesis ImplantationAortic aneurysmAneurysmlawGermanyCardiac tamponademedicineHumansIn patientRegistriesAgedAged 80 and overAortic dissectionbusiness.industryPatient SelectionAge FactorsGeneral MedicineOdds ratiomedicine.diseaseIntensive care unitConfidence intervalAortic AneurysmSurgeryAortic DissectionTreatment OutcomeAcute DiseaseFemaleSurgeryEmergenciesCardiology and Cardiovascular MedicinebusinessEuropean Journal of Cardio-Thoracic Surgery
researchProduct

Effect of platform switching on crestal bone levels around implants in the posterior mandible: 3 years results from a multicentre randomized clinical…

2016

Objective Evaluation of differences in the clinical performance and crestal bone levels between implants restored with single crowns with platform-matched or platform-switched abutments after 3 years. Material and Methods The study enrolled adult patients missing two or more adjacent teeth in the posterior mandible with natural teeth mesial to the implant site. Randomization followed open-flap implant insertion and the corresponding matching or switching healing abutments placed at surgery. Conventional loading was made with cemented crowns. Clinical follow-up took place annually after loading up to 3 years. Bone level changes were measured in standardized radiographs as the variation in cr…

MaleRandomizationimplantRadiographyPlatform switchingAlveolar Bone LossDentistryDental AbutmentsMandiblelaw.inventioncrestal bone preservation03 medical and health sciences0302 clinical medicineRandomized controlled trialDental AbutmentslawMedicineHumansstandardized radiographDental ImplantsCrestal boneCrownsbusiness.industryplatform switchingDental Implantation EndosseousMandiblebone level030206 dentistryMiddle AgedDental Prosthesis Designimplant success030220 oncology & carcinogenesisRandomized Clinical Trialplatform matchPeriodonticsFemaleImplantbusinessImplant TherapyFollow-Up StudiesJournal of clinical periodontology
researchProduct

Obstructive uropathy following aortofemoral graft surgery.

1991

Fifty patients who had undergone aorto-bifemoral bypass with a bifurcated Dacron graft for aortoiliac arteriosclerotic obliteration were examined with real-time sectorial ultrasound to screen for the presence of hydronephrosis. Hydronephrosis was detected in only 1 case. The low incidence of this complication in our cases may be due to the fact that all our patients were explored at least 1 year after surgery. Some may have developed hydronephrosis early, but this may have resolved spontaneously during the first year after the operation, thus remaining undiagnosed. Pathogenic mechanisms suggested for the development of hydronephrosis and therapeutic approaches are discussed. We conclude tha…

MaleReconstructive surgerymedicine.medical_specialtyUrologyUrinary systemmedicine.medical_treatmentAortic DiseasesArterial Occlusive DiseasesFemoral arteryHydronephrosisProsthesisPostoperative Complicationsmedicine.arterymedicineHumansAorta AbdominalHydronephrosisObstructive uropathyUltrasonographybusiness.industryAbdominal aortaMiddle Agedmedicine.diseaseSurgeryBlood Vessel ProsthesisFemoral ArteryRadiologybusinessComplicationFollow-Up StudiesUrologia internationalis
researchProduct

Working-Age Cataract Patients: Visual Results, Reading Performance, and Quality of Life with Three Diffractive Multifocal Intraocular Lenses

2013

Purpose To compare the visual outcomes, reading performance, and quality of life (QoL) of working-age cataractous patients bilaterally implanted with 3 different diffractive multifocal intraocular lenses (MIOLs). Design Two-center, randomized, prospective, double-masked study. Participants Sixty-three consecutive patients (126 eyes) seen at Ophthalmology Section, Palermo and Florence University, Italy, randomized to receive the ReSTOR SN6AD3 (Alcon Laboratories, Inc, Irvine, CA) (20 patients, group A), ReSTOR SN6AD1 (Alcon Laboratories, Inc) (21 patients, group B), or TECNIS ZMA00 (Abbott Medical Optics, Santa Ana, CA) (22 patients, group C) MIOL. Intervention Phacoemulsification. Main Outc…

MaleRefractive errorVisual acuitygenetic structuresMesopic visionmedicine.medical_treatmentMesopic VisionVisual AcuitySettore MED/42 - Igiene Generale E ApplicataLens Implantation IntraocularSickness Impact ProfileSurveys and QuestionnairesMedicineContrast (vision)Prospective StudiesProspective cohort studyOPTICAL-QUALITYmedia_commonLenses IntraocularVision BinocularOUTCOMESMiddle AgedRESTORFemalemedicine.symptomA+3.00 DPhotopic visionDIOPTER ADDITIONmedicine.medical_specialtyINSTITUTE-REFRACTIVE ERRORmedia_common.quotation_subjectMODELSProsthesis DesignCataractDouble-Blind MethodOphthalmologyCONTRAST SENSITIVITYHumansBILATERAL IMPLANTATIONPhacoemulsificationColor Visionbusiness.industrySettore MED/30 - Malattie Apparato VisivoPhacoemulsificationMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyVISIONINSTITUTE-REFRACTIVE ERROR; CONTRAST SENSITIVITY; BILATERAL IMPLANTATION; DIOPTER ADDITION; OPTICAL-QUALITY; A+3.00 D; VISION; RESTOR; OUTCOMES; MODELSReadingQuality of LifeOptometryMultifocal IOL diffractive Quality of lifebusinessFollow-Up Studies
researchProduct

Identification of optimal device combinations for the chimney endovascular aneurysm repair technique within the PERICLES registry

2018

Abstract Objective The ideal stent combination for chimney endovascular aneurysm repair remains undetermined. Therefore, we sought to identify optimal aortic and chimney stent combinations that are associated with the best outcomes by analyzing the worldwide collected experience in the PERformance of chImney technique for the treatment of Complex aortic pathoLogiES (PERICLES) registry. Methods The PERICLES registry was reviewed for patients with pararenal aortic disease electively treated from 2008 to 2014. Eleven different aortic devices were identified with three distinct subgroups: group A (n = 224), nitinol/polyester; group B (n = 105), stainless steel/polyester; and group C (n = 69), n…

MaleRegistrieTime FactorsEndoleakmedicine.medical_treatmentComorbidity030204 cardiovascular system & hematology030230 surgeryEndovascular aneurysm repairSettore MED/22 - Chirurgia VascolareAortic aneurysm0302 clinical medicineRisk FactorsRetrospective StudieOcclusionOdds RatioStentRegistriesMultivariate AnalysiPolytetrafluoroethyleneAged 80 and overEndovascular ProceduresHazard ratioGraft Occlusion VascularEuropeBlood Vessel ProsthesiTreatment OutcomeCardiothoracic surgeryStentsFemaleCardiology and Cardiovascular MedicineSTENT GRAFT; CHIMENY GRAFT; CHIMNEY TECHINQUEHumanUnited Statemedicine.medical_specialtyHospitals Low-VolumeTime FactorPolyestersPolyesterProsthesis DesignDisease-Free Survival03 medical and health sciencesBlood Vessel Prosthesis ImplantationBlood vessel prosthesisAlloysmedicineHumansProportional Hazards ModelsRetrospective StudiesAgedEndovascular ProcedureAortic Aneurysm Thoracicbusiness.industryRisk FactorStentOdds ratiomedicine.diseaseStainless SteelUnited StatesBlood Vessel ProsthesisSurgeryMultivariate AnalysisAlloyProportional Hazards ModelSurgerybusinessHospitals High-VolumeAortic Aneurysm Abdominal
researchProduct

Modified Danielson Technique for Prosthetic Aortic Valve Endocarditis and Aortoventricular Discontinuity

2020

Endocarditis is a devastating complication of prosthetic aortic valve replacement. The infective process can destroy aortic annulus tissue, making conventional surgical valve replacement difficult or impossible and causing aortoventricular discontinuity. Several treatment techniques have been proposed. One of these, the Danielson technique, involves translocating the aortic valve to the native ascending aorta, débriding the abscess cavity, closing the coronary ostia, and bypassing the coronary arteries with a Y anastomosis between 2 vein grafts. We describe our use of a modified Danielson technique in a 68-year-old man with advanced prosthetic valve endocarditis that was associated with aor…

MaleReoperationAortic valvemedicine.medical_specialtyProsthesis-Related Infectionsmedicine.medical_treatmentAnastomosisValve replacementAortic valve replacementmedicine.arteryAscending aortaHumansMedicineEndocarditisCardiac skeletonCardiac Surgical ProceduresAgedbusiness.industryEndocarditis Bacterialmedicine.diseaseTechniquesSurgeryCoronary arteriesmedicine.anatomical_structureEchocardiographyAortic ValveHeart Valve Prosthesiscardiovascular systemCardiology and Cardiovascular MedicinebusinessTexas Heart Institute Journal