Search results for "pull"
showing 10 items of 125 documents
Fabrication, characterization, thermal stability and nanoassemblies of novel pullulan-aspirin conjugates
2017
Abstract Present study deals with homogeneous and one-pot synthesis of novel macromolecular prodrugs (MPDs) of aspirin onto naturally occurring hydrophilic biopolymer pullulan. Pullulan-aspirin conjugates were synthesized by using green carboxylic acid activating reagent 1,1′-carbonyldiimidazole (CDI). The aspirin was first reacted with CDI to prepare aspirin-imidazolide at RT for 24 h which in situ reacted with pre-dissolved pullulan and the reaction preceded further for 24 h at 80 °C under nitrogen. Degree of substitution (DS 0.32–0.40) of aspirin onto pullulan was calculated from 1H NMR spectroscopy. Spectroscopic techniques confirmed the high covalent drug loading and purity. Thermal an…
High-Efficiency Regulation Method for a Zero-Current and Zero-Voltage Current-Fed Push–Pull Converter
2011
A new high-efficiency regulation method for a zero-current and zero-voltage current-fed push-pull converter is presented. The method proposed is based on the use of a controlled transformer as a post-regulator, which adds or subtracts an additional voltage to the output filter of the converter. An auxiliary regulator, which only handles a percentage of the output power, controls this transformer, and therefore, results in much higher efficiency than a normal preregulator would have. The novelty of the presented converter is that regulation is achieved without affecting the zero-voltage and zero-current switching in any working conditions. Small- and large-signal models of the converter have…
Gender differences in elite athletes heart rate dynamics following a supra maximal complex effort
2017
Regarding the importance of recovery in sport performance assessment of post exercise Heart Rate HR Dynamics has become a useful tool to understand such an individual process Heart Rate Variability HRV analysis is widely used as a non invasive marker of Autonomic Nervous System regulation of HR where the nonlinear methods Detrended Fluctuation Analysis DFA have become a promising complementary analysis technique In order to deepen on the effects of supra maximal complex efforts integrating specific endurance and strength requirements on cardiac autonomic regulation our research group is working in different protocols looking for the analysis of specific responses under supra maximal exertio…
Dependence of fracture toughness of composite laminates on interface ply orientations and delamination growth direction
2004
A critical review has been performed of the published experimental research concerning delamination onset and growth in composite laminate interfaces of different lay-ups under single-mode loadings. It was found that, depending on the loading mode and interface lay-up, the traditional fracture toughness characterization by unidirectionally reinforced composite tests can lead to marked under- or overestimation of material resistance to crack growth. Empirical models of fracture toughness as a function of delamination front orientation with respect to reinforcement directions of the adjacent laminae have been validated and their applicability range established.
Computation of lock-in range for classic PLL with lead-lag filter and impulse signals
2016
For a classic PLL with square waveform signals and lead-lag filter for all possible parameters lock-in range is computed and corresponding diagrams are given. peerReviewed
Finite element modelling of slipage between FRP rebar and concrete in pull-out test
2014
The paper presents numerical results of direct pull-out test of glass fiber-reinforced polymer (GFRP) rebars embedded in concrete. Rebars of three different cross-sections are considered: circular without longitudinal ribs and with two and four ribs. The design analyses of the rebar configurations embedded in concrete are investigated by the 3D finite element method (FEM), which takes into account the non-linearity using ANSYS software. The results of the numerical model with two ribs were compared with the experimental results. Then, the effect of different rebar geometries to the load-slip pull-out curves was studied. It is concluded that the influence of rib height and width on the pull-…
Attractors of stochastic lattice dynamical systems with a multiplicative noise and non-Lipschitz nonlinearities
2012
AbstractIn this paper we study the asymptotic behavior of solutions of a first-order stochastic lattice dynamical system with a multiplicative noise.We do not assume any Lipschitz condition on the nonlinear term, just a continuity assumption together with growth and dissipative conditions, so that uniqueness of the Cauchy problem fails to be true.Using the theory of multi-valued random dynamical systems we prove the existence of a random compact global attractor.
The Egan problem on the pull-in range of type 2 PLLs
2021
In 1981, famous engineer William F. Egan conjectured that a higher-order type 2 PLL with an infinite hold-in range also has an infinite pull-in range, and supported his conjecture with some third-order PLL implementations. Although it is known that for the second-order type 2 PLLs the hold-in range and the pull-in range are both infinite, the present paper shows that the Egan conjecture may be not valid in general. We provide an implementation of the third-order type 2 PLL, which has an infinite hold-in range and experiences stable oscillations. This implementation and the Egan conjecture naturally pose a problem, which we will call the Egan problem: to determine a class of type 2 PLLs for …
The ziqqurath of exact sequences of n-groupoids
2011
In this work we study exactness in the sesqui-category of n-groupoids. Using homotopy pullbacks, we construct a six term sequence of (n-1)-groupoids from an n-functor between pointed n-groupoids. We show that the sequence is exact in a suitable sense, which generalizes the usual notions of exactness for groups and categorical groups. Moreover, iterating the process, we get a ziqqurath of exact sequences of increasing length and decreasing dimension. For n = 1 we recover a classical result due to R. Brown and, for n = 2 its generalizations due to Hardie, Kamps and Kieboom and to Duskin, Kieboom and Vitale.
European experiences with push-and-pull enteroscopy in double-balloon technique (double-balloon enteroscopy).
2006
This article describes research concerning push-and-pull enteroscopy. Clear and possible indications for this technique are highlighted.