Search results for "quantitative analysi"

showing 10 items of 307 documents

A new principle to normalize plasma concentrations allowing single-sample clearance determinations in both children and adults.

1992

A sufficiently accurate quantification of renal function requiring only one plasma sample without an additional gamma-camera study has, until now, only been possible in adults. A new principle will be presented here allowing the universal application of known algorithms, regardless of the clearance substance used, by normalizing the plasma concentrations with respect to the individual body dimensions of the patients - for infants as well as for adults. In this respect, algorithms are developed for clearance determinations using technetium-99m mercaptoacetyltriglycine (99mTc-MAG3), which are based on steady-state studies as the reference. They allow the calculation of quantitative clearance …

AdultAdolescentRenal functionSingle sampleKidneylaw.inventionRenal CirculationTechnetium Tc 99m MertiatidelawBlood plasmaMedicineHumansRadiology Nuclear Medicine and imagingChildRadionuclide ImagingGamma camerabusiness.industryInfant NewbornInfantGeneral MedicineOrganotechnetium CompoundsStandard errorChild PreschoolPlasma concentrationbusinessNuclear medicineQuantitative analysis (chemistry)OligopeptidesAlgorithmsBlood samplingEuropean journal of nuclear medicine
researchProduct

Interleukin-6 in plasma collected with an indwelling cannula reflects local, not systemic, concentrations.

1994

AdultMalePathologymedicine.medical_specialtybiologybusiness.industryInterleukin-6medicine.medical_treatmentBiochemistry (medical)Clinical BiochemistryMiddle AgedCannulaCytokineCatheters IndwellingRegional Blood FlowBlood plasmaImmunologybiology.proteinMedicineHumansFemalebusinessInterleukin 6Quantitative analysis (chemistry)Clinical chemistry
researchProduct

Immunonephelometric determination of the C4b-binding protein.

1993

A fully mechanised immunonephelometric method for the rapid and specific determination of C4b-binding protein (C4b-BP) in citrated plasma is described. The method utilizes commercially available rabbit antiserum against human C4b-BP and a nephelometer analyser. A single determination can be performed within 6 min, requiring 80 microliters sample volume. The measuring range is about 10 to 200% of normal C4b-BP. Precision is characterized by intraassay coefficients of variation between 1.5% and 2.8%, and interassay coefficients of variation between 4.0% and 4.6% for the same C4b-BP concentrations. The nephelometry of C4b-BP was correlated with electroimmunodiffusion (Laurell technique; r = 0.…

AdultMalePercentileImmunodiffusionAnalytical chemistryAdministration Oralchemical and pharmacologic phenomenaFibrinogenRabbit antiserumNephelometry and TurbidimetryBlood plasmamedicineComplement C4bHumansAgedGlycoproteinsInflammationComplement Inactivator ProteinsChromatographyChemistryC4b-binding proteinHeparinHealthy subjectsAnticoagulantsHematologyMiddle AgedEvaluation Studies as TopicFemaleCarrier ProteinsQuantitative analysis (chemistry)Nephelometrymedicine.drugThrombosis research
researchProduct

Automated Determination of Fluvoxamine in Plasma by Column-Switching High-Performance Liquid Chromatography

1992

Abstract A column-switching system with high-performance liquid-chromatographic separation and ultraviolet detection is described for automated determination of fluvoxamine in human plasma or serum. Samples were injected and the drug was retained in a clean-up column [20 x 4.6 mm (i.d.)] filled with C8 reversed-phase material (10-micron particles). After unwanted material was washed out, the drug was eluted and separated with an analytical chromatography column, 4.6 x 250 mm (i.d.), filled with Nucleosil 100 CN (5-micron particles) with an acetonitrile:methanol:0.01 mol/L phosphate buffer eluent (188:578:235 by vol) at a flow rate of 1.5 mL/min for < 20 min and detected by spectromet…

AdultMaleQuality ControlDetection limitAutoanalysisChromatographyDepressionChemistryElutionBiochemistry (medical)Clinical BiochemistryFluvoxamineMiddle AgedMass spectrometryHigh-performance liquid chromatographyColumn chromatographyFluvoxaminemedicineHumansFemaleChromatography columnQuantitative analysis (chemistry)Chromatography High Pressure LiquidAgedmedicine.drugClinical Chemistry
researchProduct

Automated Determination of Ziprasidone by HPLC With Column Switching and Spectrophotometric Detection

2005

An isocratic high-performance liquid chromatography (HPLC) method with column switching and ultraviolet (UV) detection is described for quantitative analysis of the new antipsychotic drug ziprasidone. After centrifugation of serum or plasma samples and addition of fluperlapine as internal standard, the samples were injected into the HPLC system. On-line sample clean-up was conducted on a column (10 x 4.0 mm ID) filled with silica C8 material (20-microm particle size) using 8% (vol/vol) acetonitrile in deionized water as eluent. Ziprasidone was eluted and separated on ODS Hypersil C18 material (5 microm; column size 250 x 4.6 mm ID) using acetonitrile-water-tetramethylethylendiamine (50:49.6…

AdultMaleTime FactorsSensitivity and SpecificityHigh-performance liquid chromatographyDrug Administration SchedulePiperazinesAutomationBenzodiazepinesBlood serumColumn chromatographymedicineHumansPharmacology (medical)ZiprasidoneClozapineChromatography High Pressure LiquidPharmacologyDetection limitChromatographymedicine.diagnostic_testElutionChemistryReproducibility of ResultsMiddle AgedThiazolesOlanzapineSpectrophotometryTherapeutic drug monitoringSchizophreniaFemaleDrug MonitoringQuantitative analysis (chemistry)medicine.drugTherapeutic Drug Monitoring
researchProduct

Quantitative analysis of emphysema in 3D using MDCT: Influence of different reconstruction algorithms

2008

Abstract Purpose The aim of the study was to compare the influence of different reconstruction algorithms on quantitative emphysema analysis in patients with severe emphysema. Material and methods Twenty-five patients suffering from severe emphysema were included in the study. All patients underwent inspiratory MDCT (Aquilion-16, slice thickness 1/0.8 mm). The raw data were reconstructed using six different algorithms: bone kernel with beam hardening correction (BHC), soft tissue kernel with BHC; standard soft tissue kernel, smooth soft tissue kernel (internal reference standard), standard lung kernel, and high-convolution kernel. The only difference between image data sets was the algorith…

AdultMalegenetic structuresinformation scienceAbsolute differenceStatistics NonparametricPulmonary function testingImaging Three-DimensionalHumansMedicinenatural sciencesRadiology Nuclear Medicine and imagingLung volumesAgedPhantoms Imagingbusiness.industryfood and beveragesSoft tissueReconstruction algorithmGeneral MedicineMiddle AgedRespiratory Function TestsPulmonary EmphysemaKernel (statistics)Radiographic Image Interpretation Computer-AssistedFemaleTomographyTomography X-Ray ComputedbusinessNuclear medicineAlgorithmQuantitative analysis (chemistry)AlgorithmsSoftwareEuropean Journal of Radiology
researchProduct

Enhanced oxidative susceptibility and reduced antioxidant content of metabolic precursors of small, dense low-density lipoproteins.

2001

Abstract PURPOSE: Elevated plasma concentrations of low-density lipoproteins (LDL) increase risk for coronary heart disease. However, lipoprotein profiles rich in small, dense LDL particles confer greater risk than those that mainly consist of large, buoyant LDL. This may be due, in part, to the greater oxidative susceptibility of small, dense LDL. In the current studies, we tested whether differences in the oxidative behavior of buoyant and dense LDL arise from differences in their immediate metabolic precursors, intermediate-density lipoproteins. SUBJECTS AND METHODS: We compared the properties of intermediate-density lipoproteins and buoyant and dense LDL subfractions in 9 subjects with …

AdultMalemedicine.medical_specialtyAntioxidantParinaric Acidmedicine.medical_treatmentOxidative phosphorylationAntioxidantsReference ValuesInternal medicineMedicineHumansPolyacrylamide gel electrophoresisFluorescent DyesIntermediate-density lipoproteinbusiness.industryGeneral MedicineLipoproteins LDLEndocrinologyPhenotypeFatty Acids Unsaturatedlipids (amino acids peptides and proteins)Electrophoresis Polyacrylamide GelFemaleUltracentrifugebusinessQuantitative analysis (chemistry)Oxidation-ReductionLipoproteinThe American journal of medicine
researchProduct

Comparison of UV and charged aerosol detection approach in pharmaceutical analysis of statins

2009

Abstract CAD (charged aerosol detector) has recently become a new alternative detection system in HPLC. This detection approach was applied in a new HPLC method for the determination of three of the major statins used in clinical treatment—simvastatin, lovastatin and atorvastatin. The method was optimized and the influence of individual parameters on CAD response and sensitivity was carefully studied. Chromatography was performed on a Zorbax Eclipse XDB C18 (4.6 mm × 75 mm, 3.5 μm), using acetonitrile and formic acid 0.1% as mobile phase. The detection was performed using both CAD (20 pA range) and DAD (diode array detector—238 nm) simultaneously connected in series. In terms of linearity, …

AerosolsSimvastatinAccuracy and precisionChromatographyChemistryFormic acidDetectorAnalytical chemistryLinearityCADHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundEquipment and SuppliesHeptanoic AcidsWide dynamic rangeAtorvastatinPyrrolesLovastatinHydroxymethylglutaryl-CoA Reductase InhibitorsQuantitative analysis (chemistry)Chromatography High Pressure LiquidTabletsTalanta
researchProduct

Determination of nitrite by inhibition of the chemiluminescence of acriflavine in a flow-injection assembly

2001

The indirect determination of nitrite was performed with a flow-injection assembly on the basis of the inhibition of the analytical output obtained in a luminometer by oxidation of acriflavine. The acriflavine solution merged with the nitrite and the resulting mixture was injected into a pure water stream. This solution merged with the oxidant solution (potassium permanganate in sulfuric acid medium) and the resulting chemiluminiscence was affected (inhibited) by the presence of nitrite after reaction with the aminoacridine. The method was applicable over the range 10–800 μg l−1 of nitrite with a correlation coefficient of 0.9960. The relative standard deviation was 1.4% and the throughput …

AminoacridineChromatographyInorganic chemistrySulfuric acidAmberliteBiochemistryAnalytical Chemistrylaw.inventionchemistry.chemical_compoundPotassium permanganatechemistrylawFlow Injection AnalysisLuminescent MeasurementsElectrochemistryEnvironmental ChemistryAcriflavineEnvironmental PollutantsAcriflavineNitriteQuantitative analysis (chemistry)NitritesSpectroscopyChemiluminescenceThe Analyst
researchProduct

The generalized H-point standard-additions method to determine analytes present in two different chemical forms in unknown matrix samples. Part II. C…

2000

The generalized H-point standard-additions method (GHPSAM) is used in order to obtain the total Cr(VI) and chromate concentration in water samples whose matrices are completely unknown. Moreover, a new methodology, which is a modification of the GHPSAM, is proposed for the simultaneous determination of the two major chemical forms of Cr(VI) present in the sample. The method is based on the location of spectral intervals where the behaviour of the interferent absorbance can be considered as linear. From these intervals, the analyte concentration free from bias error can be estimated. Spiked samples of dig and harbour water measured in the UV–visible spectral region have been tested to check …

AnalyteAbsorption spectroscopyChromate conversion coatingChemistryAnalytical chemistryBiochemistryAnalytical ChemistryChemometricsAbsorbanceMatrix (mathematics)Standard additionElectrochemistryEnvironmental ChemistryQuantitative analysis (chemistry)SpectroscopyThe Analyst
researchProduct