Italian inter-society expert panel position on radiological exposure in Neonatal Intensive Care Units.
2020
Abstract Background In the recent years, clinical progress and better medical assistance for pregnant women, together with the introduction of new complex technologies, has improved the survival of preterm infants. However, this result requires frequent radiological investigations mostly represented by thoracic and abdominal radiographs in incubators. This document was elaborated by an expert panel Italian inter-society working group (Radiologists, Paediatricians, Medical Physicists) with the aim to assist healthcare practitioners in taking choices involving radiation exposures of new-born infants and to provide practical recommendations about justification and optimization in Neonatal Inte…
CT coronary angiography at an ultra-low radiation dose (< 0.1 mSv): feasible and viable in times of constraint on healthcare costs
2013
Computed tomography coronary angiography (CTCA) has reached very high standards both in terms of diagnostic performance and radiation dose reduction. This commentary follows a report on CTCA using less than 0.1 mSv in selected patients. This is an extraordinary accomplishment, both for technology and for medicine. The difficult task is now to implement this tool in clinical practice so it can play the best possible role. CTCA can improve diagnostic pathways, can save money for healthcare systems and could even improve pharmacological therapy. All of this may happen, but it will require the combined effort of all the experienced operators in this field, including the referring clinicians. In…
Overdiagnosis and overimaging: an ethical issue for radiological protection
2019
Aims and objectives: This study aimed to analyse the key factors that influence the overimaging using X-ray such as self-referral, defensive medicine and duplicate imaging studies and to emphasize the ethical problem that derives from it. Materials and methods: In this study, we focused on the more frequent sources of overdiagnosis such as the total-body CT, proposed in the form of screening in both public and private sector, the choice of the most sensitive test for each pathology such as pulmonary embolism, ultrasound investigations mostly of the thyroid and of the prostate and MR examinations, especially of the musculoskeletal system. Results: The direct follow of overdiagnosis and overi…
Quality control for exposure assessment in epidemiological studies
2010
In the framework of an epidemiological study, dosemeters were used for the assessment of radio frequency electromagnetic field exposure. To check the correct dosemeter's performance in terms of consistency of recorded field values over the entire study period, a quality control strategy was developed. In this paper, the concept of quality control and its results is described. From the 20 dosemeters used, 19 were very stable and reproducible, with deviations of a maximum of +/- 1 dB compared with their initial state. One device was found to be faulty and its measurement data had to be excluded from the analysis. As a result of continuous quality control procedures, the confidence in the meas…
Evidence for a teratogenic risk in the offspring of health personnel exposed to ionizing radiation?!
2016
Background The evidence concerning safety of occupational exposure to ionizing radiation on teratogenic effects mainly relies on animal models, disaster epidemiology and experience in cancer etiology. Following an explorative result on maternal exposure in medical occupations we conducted a feasibility study, addressing congenital anomalies (CA) in the offspring of health workers potentially exposed to radiation. Methods In a prospective follow-up study, we enrolled women, identified by mandatory registration at the office of radiation protection as wearing a dosimeter. The participating women answered a questionnaire and if pregnant agreed to an examination of their infant. CA were diagnos…
Radiation leakage study for the Valencia applicators
2011
Abstract Introduction and purpose The Valencia applicators which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands) are designed to treat skin lesions. These cup-shaped applicators are an alternative to superficial/orthovoltage x-ray treatment units. They limit the irradiation to the required area using tungsten-alloy shielding, and are equipped with a tungsten-alloy flattering filter allowing the treatment of skin tumors, the oral cavity, vaginal cuff, etc. The tungsten-alloy thickness to shield radiation is not the same in all parts of the applicators. This fact led us to question whether the leakage radiation differs depending on where it is me…
Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy.
2014
In surface and interstitial high-dose-rate brachytherapy with either (60)Co, (192)Ir, or (169)Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields…
Risk assessment of component failure modes and human errors using a new FMECA approach: application in the safety analysis of HDR brachytherapy
2014
Failure mode, effects and criticality analysis (FMECA) is a safety technique extensively used in many different industrial fields to identify and prevent potential failures. In the application of traditional FMECA, the risk priority number (RPN) is determined to rank the failure modes; however, the method has been criticised for having several weaknesses. Moreover, it is unable to adequately deal with human errors or negligence. In this paper, a new versatile fuzzy rule-based assessment model is proposed to evaluate the RPN index to rank both component failure and human error. The proposed methodology is applied to potential radiological over-exposure of patients during high-dose-rate brach…
FIRST experiment: Fragmentation of Ions Relevant for Space and Therapy
2013
International audience; Nuclear fragmentation processes are relevant in different fields of basic research and applied physics and are of particular interest for tumor therapy and for space radiation protection applications. The FIRST (Fragmentation of Ions Relevant for Space and Therapy) experiment at SIS accelerator of GSI laboratory in Darmstadt, has been designed for the measurement of different ions fragmentation cross sections at different energies between 100 and 1000 MeV/nucleon. The experiment is performed by an international collaboration made of institutions from Germany, France, Italy and Spain. The experimental apparatus is partly based on an already existing setup made of the …
Monte Carlo evaluation of kerma in an HDR brachytherapy bunker
2004
In recent years, the use of high dose rate (HDR) after-loader machines has greatly increased due to the shift from traditional Cs-137/Ir-192 low dose rate (LDR) to HDR brachytherapy. The method used to calculate the required concrete and, where appropriate, lead shielding in the door is based on analytical methods provided by documents published by the ICRP, the IAEA and the NCRP. The purpose of this study is to perform a more realistic kerma evaluation at the entrance maze door of an HDR bunker using the Monte Carlo code GEANT4. The Monte Carlo results were validated experimentally. The spectrum at the maze entrance door, obtained with Monte Carlo, has an average energy of about 110 keV, m…