Search results for "radiometry"

showing 10 items of 170 documents

Automatic generation of emissivity maps on a European scale

2009

The remote sensing measurement of the land surface temperature from satellites provides an overview of this magnitude on a continuous and regular basis. The study of its evolution in time and space is a critical factor in many scientific fields such as weather forecasting, detection of forest fires, climate change, and so on. The main problem of making this measurement from satellite data is the need to correct the effects of the atmosphere and the surface emissivity. In this work, these corrections have been made using a split-window algorithm. The aim was to define an enhanced vegetation cover method and develop a system that used it, in order to automatically generate maps of land surfac…

MeteorologyEmissivityWeather forecastingMagnitude (mathematics)Climate changeRadiometryEnvironmental scienceAATSRVegetationScale (map)computer.software_genrecomputerRemote sensing2009 IEEE International Geoscience and Remote Sensing Symposium
researchProduct

Implementation of dosimetry equipment and phantoms at the MedAustron light ion beam therapy facility

2017

Purpose: To describe the implementation of dosimetry equipment and phantoms into clinical practice of light ion beam therapy facilities. This work covers standard dosimetry equipment such as computerized water scanners, films, 2D-array, thimble and plane parallel ionization chambers, but also dosimetry equipment specifically devoted to the pencil beam scanning delivery technique such as water columns, scintillating screens or multi-layer ionization chambers. Method: Advanced acceptance testing procedures developed at MedAustron and complementary to the standard acceptance procedures proposed by the manufacturer are presented. Detailed commissioning plans have been implemented for each piece…

medicine.medical_specialtyIon beamComputer scienceNuclear engineeringmedicine.medical_treatmentImaging phantomPelvis030218 nuclear medicine & medical imagingMedical physicist03 medical and health sciences0302 clinical medicinemedicineHumansDosimetryMedical physicsRadiometryPencil-beam scanningIonsPhantoms ImagingRadiation DosimetersUncertaintyGeneral MedicinePencil (optics)Radiation therapy030220 oncology & carcinogenesisSoftwareMedical Physics
researchProduct

Atmospheric water vapor content over land surfaces derived from the AVHRR data: application to the Iberian Peninsula

1999

A study has been carried out using simulated NOAA/advanced very high resolution radiometer (AVHRR) data at 11 and 12 /spl mu/m (with LOWTRAN-7, MODTRAN 2.0, and the TIGR database), AVHRR images of the Iberian Peninsula and the Palma de Mallorca Island, radiosonde observations at seven meteorological stations, and the AVISO database provided by Meteo France to describe, compare, and analyze two different approaches for estimating the total atmospheric water vapor content (W) over land surfaces from AVHRR data. These two techniques are: 1) the split-window covariance-variance ratio (SWCVR), based on a quadratic relationship between W and the ratio of the spatial covariance and variance of bri…

Advanced very-high-resolution radiometerMODTRANAtmospheric modelStandard deviationlaw.inventionlawBrightness temperatureRadiosondeGeneral Earth and Planetary SciencesRadiometryEnvironmental scienceElectrical and Electronic EngineeringWater vaporRemote sensingIEEE Transactions on Geoscience and Remote Sensing
researchProduct

Dosimetric effect of respiratory motion on planned dose in whole-breast volumetric modulated arc therapy using moderate and ultra-hypofractionation.

2021

Abstract Background and purpose The interplay effect of respiratory motion on the planned dose in free-breathing right-sided whole-breast irradiation (WBI) were studied by simulating hypofractionated VMAT treatment courses. Materials and methods Ten patients with phase-triggered 4D-CT images were included in the study. VMAT plans targeting the right breast were created retrospectively with moderately hypofractionated (40.05 Gy in 15 fractions of 2.67 Gy) and ultra-hypofractionated (26 Gy 5 fractions of 5.2 Gy) schemes. 3D-CRT plans were generated as a reference. All plans were divided into respiratory phase-specific plans and calculated in the corresponding phase images. Fraction-specific d…

Lung Neoplasmsrespiratory motionrintasyöpäultrahypofractionationwhole-breast irradiationRadiotherapy Dosagevolumetric modulated arc therapysädehoitobreast cancersäteilyannoksetOncologyhengitysHumansRadiology Nuclear Medicine and imagingRadiation Dose HypofractionationRadiotherapy Intensity-ModulatedradiologiaRadiometryRetrospective StudiesRadiation oncology (London, England)
researchProduct

A Comparative Study of Land Surface Emissivity Retrieval from NOAA Data

2001

Abstract A comparative study has been carried out on the most recent algorithms for the estimation of land surface emissivity (ϵ) using Advanced Very High Resolution Radiometer (AVHRR) data. Three of the algorithms are based on the Temperature-Independent Spectral Indices (TISI) concept using atmospherically corrected channels 3, 4, and/or 5, namely: (1) TISI BL , (2) TS-RAM, and (3) Δ day. The fourth is a simplified method based on the estimation of ϵ using atmospherically corrected data in the visible and near-infrared channels, called Normalized Difference Vegetation Index (NDVI) Thresholds Method (NDVI THM ). This method integrates a wide spectral data set of bare soil reflectivity meas…

MeteorologyAdvanced very-high-resolution radiometerSoil ScienceGeologyVegetationNormalized Difference Vegetation IndexRoot mean squareData retrievalEmissivityRadiometryEnvironmental scienceComputers in Earth SciencesRoot-mean-square deviationRemote sensingRemote Sensing of Environment
researchProduct

Calibration and Validation of Algorithms for the Estimation of Chlorophyll-A in Inland Waters with Sentinel-2

2018

The Ocean Color 2 (OC2), Ocean Color 3 (OC3) and Dall'Olmo three-band (TBDO) algorithms used for the estimation of the chlorophyll-a concentration [Chl-a] have been calibrated and validated for Sentinel-2 spectral bands. Measurements of in situ chlorophyll-a, radiometry and simulations with HydroLight have been used for this purpose within the Ecological Status of AQuatic Systems Satellites (ESAQS) Project to estimate water quality in aquatic systems in Spain. The results show that Sentinel-2 spectral bands are suitable for studying the chlorophyll-a concentration in inland waters. The TBDO algorithm have been applied to Sentinel-2 images and satisfactory results have been obtained in Albuf…

EstimationChlorophyll aCalibration and validation02 engineering and technologySpectral bands021001 nanoscience & nanotechnology01 natural sciences010309 opticschemistry.chemical_compoundchemistryOcean color0103 physical sciencesCalibrationEnvironmental scienceRadiometryWater quality0210 nano-technologyAlgorithmIGARSS 2018 - 2018 IEEE International Geoscience and Remote Sensing Symposium
researchProduct

A tailor-made nucleoside-based colourimetric probe of formic acid

2014

A ratiometric, specific probe of formic acid has been developed. It is based on intermolecular nucleobase-pairing of inosine-capped plasmonic nanoparticles to form nucleoside channels, which are destabilised by the analyte.

AnalyteFormatesFormic acidCatalysischemistry.chemical_compoundmental disordersMaterials ChemistryOrganic chemistryRadiometryAcetic AcidPlasmonic nanoparticlesIntermolecular forceMetals and AlloysNucleosidesGeneral ChemistryCombinatorial chemistryGold CompoundsInosineSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialschemistrySolventsCeramics and CompositesNanoparticlesColorimetryIndicators and ReagentsChloroformNucleosideChem. Commun.
researchProduct

Radiation-induced changes in levels of selected proteins in peripheral blood serum of breast cancer patients as a potential triage biodosimeter for l…

2014

The threat of a large scale radiological emergency, where thousands of people may require fast biological dosimetry for the purpose of triage, makes it necessary to search for new, high throughput biological dosimeters. The authors tested an assay based on the quantitative analysis of selected proteins in peripheral blood serum. They were particularly interested in testing proteins that are specific to irradiation of skin, as these can be used in cases of partial body exposure. Candidate proteins were identified in an earlier study with mice, where skin of the animals was exposed to different doses of radiation and global expression of serum proteins was analyzed. Eight proteins were found,…

medicine.medical_specialtyradiation responseEpidemiologyHealth Toxicology and Mutagenesis[SDV]Life Sciences [q-bio]Radiation inducedEnzyme-Linked Immunosorbent AssayBreast NeoplasmsradiometryDose-Response RelationshipMiceBreast cancerRadiation MonitoringbloodmedicineDosimetryHumansAnimalsAnimaliaRadiology Nuclear Medicine and imaginganimalhumanproceduresRadiation Injuriesmouseemergency health serviceRadiationbusiness.industryemergencyMusDose-Response Relationship RadiationBlood Proteinsmedicine.diseasebiological markerTriagePeripheral blood3. Good healthenzyme linked immunosorbent assayfemaleplasma proteinRadiological weaponEmergency medicineBiological MarkersMedical emergencyEmergenciesTriagebusinessBiomarkers
researchProduct

Characterization of phenolic pellets for ESR dosimetry in photon beam radiotherapy

2017

This work deals with the dosimetric features of a particular phenolic compound (IRGANOX 1076 ® ) for dosimetry of clinical photon beams by using electron spin resonance (ESR) spectroscopy. After the optimization of the ESR readout parameters (namely modulation amplitude and microwave power) to maximise the signal without excessive spectrum distortions, basic dosimetric properties of laboratory-made phenolic dosimeters in pellet form, such as reproducibility, dose–response, sensitivity, linearity and dose rate dependence were investigated. The dosimeters were tested by measuring the depth dose profile of a 6 MV photon beam. A satisfactory intra-batch reproducibility of the ESR signal of the …

Models MolecularPhotonBiophysicsMolecular ConformationIRGANOX 1076 ®RadiationSignal030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineNuclear magnetic resonancePhenolsDosimetryDosimetrySpectroscopyMicrowavesRadiometryGeneral Environmental ScienceESRReproducibilityPhotonsDosimeterRadiationPhenolRadiotherapy2300ChemistryElectron Spin Resonance SpectroscopyRadiotherapy DosagePhotonBiophysic030220 oncology & carcinogenesisMicrowaveMicrowave
researchProduct

Dosimetric feasibility study for an extracorporeal BNCT application on liver metastases at the TRIGA Mainz

2010

This study investigates the dosimetric feasibility of Boron Neutron Capture Therapy (BNCT) of explanted livers in the thermal column of the research reactor in Mainz. The Monte Carlo code MCNP5 is used to calculate the biologically weighted dose for different ratios of the (10)B-concentration in tumour to normal liver tissue. The simulation results show that dosimetric goals are only partially met. To guarantee effective BNCT treatment the organ has to be better shielded from all gamma radiation.

Radiationbusiness.industryLiver NeoplasmsBoron Neutron Capture TherapyRadiotherapy DosageModels BiologicalExtracorporealTRIGANeutron captureMonte carlo codeLiver tissueHumansMedicineComputer SimulationRadiometryNuclear medicinebusinessApplied Radiation and Isotopes
researchProduct