Search results for "range"

showing 10 items of 4508 documents

An environmentally friendly multicommutated alternative to the reference method for anionic surfactant determination in water

2004

Abstract It has been developed a fully mechanized procedure for the spectrophotometric determination of anionic surfactants in water expressed in terms of SDS concentration. The reference method, based on the reaction of SDS with methylene blue (MB) followed by extraction in chloroform, was mechanized in order to reduce the consumption of organic solvents. The system was based on the multicommutation approach and provided a 35 times reduction of the waste production without sacrificing the figures of merit of the method in terms of sensitivity and repeatability, for a dynamic linear range from 0.2 to 1.7 mg l−1. Results obtained for washing water samples were comparable with those obtained …

Detection limitChromatographymedicine.diagnostic_testChemistryExtraction (chemistry)Analytical chemistryRepeatabilityAnalytical ChemistrySolventPulmonary surfactantLinear rangeSpectrophotometrymedicineSample preparationTalanta
researchProduct

DETECTION LIMITS FOR NATURAL CIRCULAR-DICHROISM OF CHIRAL COMPLEXES IN THE X-RAY RANGE

1993

Whereas both Magnetic Circular Dichroism and Faraday Rotation studies have been successfully carried out at the K-, L- and M-absorption edges of metal atoms in ferromagnetic systems, Natural optical activity of chiral complexes has not yet been detected quite unambiguously in the X-ray range. We review a number of theoretical arguments which confirm that the optical asymmetry factor gσ should be very small in the X-ray range for unoriented powdered samples, especially at the K-absorption edges. This stimulating challenge prompted us to start an intensive programme of measurements aimed at detecting natural circular dichroism in both the soft and “firm” X-ray ranges. Although some of our ex…

Detection limitCircular dichroismRange (particle radiation)Magnetic circular dichroismChemistrymedia_common.quotation_subjectXAFSSOFT-X-RAY SPECTROSCOPYGeneral EngineeringAnalytical chemistryX-rayGeneral Physics and AstronomyOPTICAL-ACTIVITYAsymmetryMolecular physicssymbols.namesakeROTATORY STRENGTHFerromagnetismNATURAL CDFaraday effectsymbolsABSORPTIONOPTICAL ASYMMETRYTRANSITION-METAL COMPLEXESmedia_commonJapanese journal of applied physics part 1-Regular papers short notes & review papers
researchProduct

Simultaneous determinations of zirconium, hafnium, yttrium and lanthanides in seawater according to a co-precipitation technique onto iron-hydroxide.

2013

Very low concentrations (pg mL(-1) or sub-pg mL(-1) level) along with the high salinity are the main problems in determining trace metal contents in seawater. This problem is mainly considered for investigations of naturally occurring YLOID (Y and Lanthanides) and Zr and Hf in order to provide precise and accurate results. The inductively coupled plasma mass spectrometry (ICP-MS), both in high and low resolution, offers many advantages including simultaneous analyses of all elements and their quantitative determination with detection limits of the order of pg mL(-1). However in the analysis of YLOID in seawater, a better determination needs an efficient combination of ICP-MS measurement wit…

Detection limitQuality ControlZirconiumSpectrophotometry AtomicAnalytical chemistrychemistry.chemical_elementFlocculationYttriumFerric CompoundsLanthanoid Series ElementsAnalytical ChemistryWorking rangeHafniumTrace ElementsCertified reference materialschemistryLimit of DetectionSeawaterSeawaterYttriumZirconiumInductively coupled plasma mass spectrometryHafniumTalanta
researchProduct

Oxidation of adrenaline and noradrenaline by solved molecular oxygen in a FIA assembly.

2002

A simple and effective procedure is proposed for the study and simultaneous determination of adrenaline and noradrenaline. The fluorimetric determination of both substances is performed in a flow injection assembly and by oxidation of both drugs with the solved molecular oxygen. The influence of different parameters is empirically studied and the interpretation of the reaction mechanism is also added. The determination of adrenaline is monitored at 450 nm and the outputs at 520 nm correspond to the adrenaline and noradrenaline global amount; for both lectures lambda(exc) 329 nm. The influence of temperature is relevant and analytical determination occurred at 55 degrees C by immersing the s…

Detection limitReaction mechanismChromatographyEpinephrineChemistryClinical BiochemistryAnalytical chemistryFluorescence spectrometryPharmaceutical ScienceFluorescence spectroscopyAnalytical ChemistryOxygenNorepinephrineLinear rangeDrug DiscoveryFlow Injection AnalysisFluorometryMolecular oxygenQuantitative analysis (chemistry)Oxidation-ReductionSpectroscopyAnalysis methodJournal of pharmaceutical and biomedical analysis
researchProduct

Selective and sentivive method based on capillary liquid chromatography with in-tube solid phase microextraction for determination of monochloramine …

2015

Abstract Due to the difficulties of working with chloramines, a critical examination of monochloramine standard preparation has been performed in order to select the best synthesis conditions. The analyte has been determined by in-tube solid phase extraction coupled to capillary liquid chromatography with UV detection (IT-SPME Capillary LC DAD). Potential factors affecting the response of monochloramine such as the pH of mobile phase and the volume of sample processed by IT-SPME Capillary LC DAD have been investigated and optimized. According to the results of the study, 0.1 mL or 4.0 mL of sample at neutral pH were loaded in the chromatographic system. A sensitive and selective method has …

Detection limitReproducibilityAnalyteChloramineChromatographyCapillary actionChloraminesOrganic ChemistryAnalytical chemistryElectrophoresis CapillaryWaterGeneral MedicineSolid-phase microextractionBiochemistryAnalytical Chemistrychemistry.chemical_compoundLinear rangechemistryLimit of DetectionSolid phase extractionSolid Phase MicroextractionWater Pollutants ChemicalChromatography LiquidJournal of Chromatography A
researchProduct

Indirect spectrophotometric determination of p-aminobenzoic acid in sunscreen formulations by sequential injection analysis

2003

Abstract A simple indirect sequential injection spectrophotometric method for the determination of the UV-filter p -aminobenzoic acid (PABA) in sunscreen formulations is proposed. The determination is based on the reaction of PABA with hypochlorite in acidic medium and the subsequent measurement of the residual chlorine by using the well-known reaction with o -tolidine. The experimental variables involved in the sequential injection analysis (SIA) system (sandwich arrangement, volumes of sample and reagents, propulsion flow rate, reaction coil length) and adequate concentrations of reagents were studied. The SIA method has a linear range up to 20 μg ml −1 (3 s y / x / b detection limit) of …

Detection limitSequential injection analysisChromatographymedicine.diagnostic_testTolidineHypochloriteBiochemistryAnalytical Chemistrychemistry.chemical_compoundLinear rangechemistrySpectrophotometryReagentmedicineEnvironmental ChemistryAminobenzoic acidSpectroscopyAnalytica Chimica Acta
researchProduct

Use of gold nanoparticle-coated sorbent materials for the selective preconcentration of sulfonylurea herbicides in water samples and determination by…

2012

Abstract Two new gold nanoparticle (NP) coated materials (silica supported on gold NP with and without ionic liquid) were synthesized for solid phase extraction of sulfonylurea herbicides (SUHs), such as bensulfuron-methyl (BSM), metsulfuron-methyl (MSM), pyrazosulfuron-methyl (PSM), thifensulfuron-methyl (TFM) and triasulfuron (TS), from water samples, followed by capillary liquid chromatography coupled to diode array detection (CLC–DAD). Several factors influencing the preconcentration efficiency of SUHs and its subsequent determination, such as pH of the sample, eluent and reusability of sorbents, have been investigated. Under the optimum conditions, the developed method allowed the dete…

Detection limitSorbentChromatographyCapillary actionHerbicidesNanoparticleMetal NanoparticlesAnalytical Chemistrychemistry.chemical_compoundColumn chromatographySulfonylurea CompoundschemistryLinear rangeMicroscopy Electron TransmissionIonic liquidSolid phase extractionGoldWater Pollutants ChemicalTalanta
researchProduct

On-line gel permeation chromatography–attenuated total reflectance–Fourier transform infrared determination of lecithin and soybean oil in dietary su…

2007

Gel permeation chromatography (GPC) with attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectrometry detection has been proposed for the simultaneous determination of lecithin and soybean oil in dietary supplements. The method involves the extraction of analytes with dichloromethane in an ultrasound water bath and the injection of 2 ml of centrifuged and filtered extracts into the system integrated by two Envirogel GPC columns (19 mm x150 mm, 19 mm x 300 mm) coupled on-line. Dichloromethane was used as mobile phase. A method has been developed to select the most appropriated wavenumber to be used for the determination of each considered compound from the calculation of a…

Detection limitfood.ingredientChromatographyFourier AnalysisChemistrySpectrum AnalysisOrganic ChemistryGeneral MedicineBiochemistryLecithinSoybean oilSoybean OilAnalytical ChemistryGel permeation chromatographyVegetable oilfoodLinear rangeAttenuated total reflectionDietary SupplementsLecithinsSpectroscopy Fourier Transform InfraredChromatography GelSoybeansFourier transform infrared spectroscopyJournal of Chromatography A
researchProduct

"A Detenção administrativa dos Estrangeiros irregulares na Itália e na União Europeia e o Direito humano fundamental à Liberdade privada e à ampla De…

2014

Na Itália, como em outros Estados da União Europeia, vem ocorrendo recentemente nos últimos anos o fenômeno da "detenção administrativa" dos cidadãos estrangeiros irregulares, bem como dos requerentes de asilo, a maioria proveniente da África, do Oriente Médio e da Península Balcânica. Esses imigrantes, pelo simples fato de terem ingressado irregularmente no território europeu, apesar da imigração ilegal não constituir delito, são privados da liberdade pessoal ou de circulação e permanência, sendo detidos pelas autoridades de segurança pública, às vezes sem a validação da autoridade jurisdicional, durante um período de tempo também muito prolongado, em determinados locais, formais ou inform…

Detenção administrativa Estrangeiros Migrantes Irregulares Requerentes de asilo Direitos fundamentaisSettore IUS/10 - Diritto AmministrativoAdministrative Detention Foreigners Migrants Asylum seekers Irregular Fundamental Human Rights
researchProduct

Biology of the preimaginal stages in trogid beetles (Coleoptera): Experimental data∗

1992

Abstract Some aspects of larval behaviour in two species of trogid beetles, Trox bispidus (Pontoppidan) from temperate Europe and Afromorgus tuberosus (Klug) from tropical Africa, have been studied experimentally. From the results obtained it emerges that the rise of the newborn larvae towards the soil surface is imputable to a simple negative geotropism. Larval food relocation also contributes to reducing aggressive interactions at the food source. The potential range of trophic and behavioural variation seems to be larger than that expressed in nature as a rule. This can contribute to explaining, in evolutive terms, the rare cases of transgression from a uniform trophic and behavioural pa…

Developmental stageLarvaTroxEcologyRange (biology)Larval behaviourTemperate climateZoologyAnimal Science and ZoologySoil surfaceBiologybiology.organism_classificationTrophic levelBolletino di zoologia
researchProduct