Search results for "rection"
showing 10 items of 965 documents
The disintegrin ADAM9 indirectly contributes to the physiological processing of cellular prion by modulating ADAM10 activity
2005
The cellular prion protein (PrP(c)) is physiologically cleaved in the middle of its 106-126 amino acid neurotoxic region at the 110/111 downward arrow112 peptidyl bond, yielding an N-terminal fragment referred to as N1. We recently demonstrated that two disintegrins, namely ADAM10 and ADAM17 (TACE, tumor necrosis factor alpha converting enzyme) participated in both constitutive and protein kinase C-regulated generation of N1, respectively. These proteolytic events were strikingly reminiscent of those involved in the so-called "alpha-secretase pathway" that leads to the production of secreted sAPPalpha from betaAPP. We show here, by transient and stable transfection analyses, that ADAM9 also…
Modeling crowd dynamics through coarse-grained data analysis
2018
International audience; Understanding and predicting the collective behaviour of crowds is essential to improve the efficiency of pedestrian flows in urban areas and minimize the risks of accidents at mass events. We advocate for the development of crowd traffic management systems, whereby observations of crowds can be coupled to fast and reliable models to produce rapid predictions of the crowd movement and eventually help crowd managers choose between tailored optimization strategies. Here, we propose a Bi-directional Macroscopic (BM) model as the core of such a system. Its key input is the fundamental diagram for bi-directional flows, i.e. the relation between the pedestrian fluxes and d…
An alternative simple approach to estimate atmospheric correction in multitemporal studies
1989
Abstract Studies that use multitemporal images require the conversion of original digital data into the corresponding physical magnitudes. Atmospheric correction is one of the most important steps in this process, which is usually undertaken using atmospheric radiative transfer models. The main difficulty in these models is the need of atmospheric input data which are not usually available. An alternative approach to atmospheric correction is proposed in this Letter. It is based on the idea that the atmospheric effects over two or more dates can be determined in a relative way, by using the apparent reflectance values of surfaces whose ground reflectance can be considered unchangeable with …
HICO L1 and L2 data processing: Radiometric recalibration, atmospheric correction and retrieval of water quality parameters
2015
The Hyperspectral Imager for the Coastal Ocean (HICO) is an imaging spectrometer designed with a very high signal-to-noise ratio to monitor coastal ocean and inland waters. The processing of Top-Of-Atmosphere radiance data down to surface reflectance is fundamental for the retrieval of water quality products. However, the current HICO processing chain does not provide atmospheric corrected data nor higher-level water quality products. This paper describes the algorithms implemented within an HICO data processing chain that includes image pre-processing, atmospheric correction and the retrieval of water quality parameters. The implemented algorithms have been validated over a set of HICO ima…
HICO level-2 data processing toolbox for the atmospheric correction and the retrieval of water quality parameters
2014
The Hyperspectral Imager for the Coastal Ocean (HICO) is an imaging spectrometer specifically designed to monitor the coastal ocean. The processing of Top-Of-Atmosphere (TOA) radiance data down to surface reflectance is fundamental for the retrieval of water quality products. However, the current HICO processing chain does not provide atmospheric corrected data nor higher-level water quality products. This work describes a toolbox for the atmospheric correction of HICO data and the retrieval of water quality products. The HICO toolbox, consisting on three main modules (image pre-processing, atmospheric correction and retrieval of water quality products), has been used over a set of HICO ima…
<title>Methodology for quantitative analysis of scaling effects in multiresolution datasets acquired with airborne sensors flying at different …
2001
Scaling issues are always playing a critical role in most studies based on remote sensing data. The process of getting quantitative scaling information from raw multi-resolution images is not trivial, and many aspects must be taken very carefully into consideration. To get a better picture about the role of spatial resolution, we conducted a series of flights in summer 1997, in several test sites over Spain and Portugal. In order to minimize the time of acquisition (to get minimal changes in atmospheric status and solar illumination) we used three flight altitude levels, that produced images with 1.25 m, 3 m and 12 m resolutions. The main steps in our methodology are: a) Geometrical registr…
Angular variations of brightness surface temperatures derived from dual-view measurements of the Advanced Along-Track Scanning Radiometer using a new…
2019
Abstract Surface temperatures derived from remote sensing data over heterogeneous, non-isothermal land surfaces depend on the viewing and solar angles mainly due to variations in sunlit and shaded fractions of the different elements in the field of view. The near-simultaneous dual-view capability of the Advanced Along-Track Scanning Radiometer (AATSR) can be used to estimate differences in brightness surface temperatures (BSTs) between the nadir (satellite zenith angle of 0°–21.7°) and forward views (53°–55.6°) in the 11 and 12 μm bands. BST is defined as the black-body temperature corresponding to the radiance at surface level (that is, corrected for atmospheric absorption and emission). W…
Effects of minute misregistrations of prefabricated markers for image-guided dental implant surgery: an analytical evaluation
2012
Objectives The goal of the present study was to develop a theoretical analysis of errors in implant position, which can occur owing to minute registration errors of a reference marker in a cone beam computed tomography volume when inserting an implant with a surgical stent. Material and methods A virtual dental-arch model was created using anatomic data derived from the literature. Basic trigonometry was used to compute effects of defined minute registration errors of only voxel size. The errors occurring at the implant's neck and apex both in horizontal as in vertical direction were computed for mean ±95%-confidence intervals of jaw width and length and typical implant lengths (8, 10 and 1…
Thermal equation of state of ruthenium characterized by resistively heated diamond anvil cell
2019
AbstractThe high-pressure and high-temperature structural and chemical stability of ruthenium has been investigated via synchrotron X-ray diffraction using a resistively heated diamond anvil cell. In the present experiment, ruthenium remains stable in the hcp phase up to 150 GPa and 960 K. The thermal equation of state has been determined based upon the data collected following four different isotherms. A quasi-hydrostatic equation of state at ambient temperature has also been characterized up to 150 GPa. The measured equation of state and structural parameters have been compared to the results of ab initio simulations performed with several exchange-correlation functionals. The agreement b…
Corrected whole blood biomarkers : the equation of Dill and Costill revisited
2018
An exercise bout or a dehydration often causes a reduction in plasma volume, which should be acknowledged when considering the change in biomarkers before and after the plasma changing event. The classic equation from Dill and Costill (1974, J. Appl. Physiol., 37, 247–248) for plasma volume shift is usually utilized in such a case. Although this works well with plasma and serum biomarkers, we argue in this note that this traditional approach gives misleading results in the context of whole blood biomarkers, such as lactate, white cells, and thrombocytes. In this study, we demonstrate that to calculate the change in the total amount of circulating whole blood biomarker, one should utilize a …