Procedimento estratégico em três estágios de seleção de variáveis para a obtenção de resultados equilibrados na pesquisa em saúde pública

2018

Multidisciplinary research in public health is approached using methods from many scientific disciplines. One of the main characteristics of this type of research is dealing with large data sets. Classic statistical variable selection methods, known as “screen and clean”, and used in a single-step, select the variables with greater explanatory weight in the model. These methods, commonly used in public health research, may induce masking and multicollinearity, excluding relevant variables for the experts in each discipline and skewing the result. Some specific techniques are used to solve this problem, such as penalized regressions and Bayesian statistics, they offer more balanced results a…

Biomedical ResearchStatistics as TopicInterdisciplinary Researchlcsh:MedicineMétodosInterdisciplinary researchPesquisa Interdisciplinar01 natural sciences010104 statistics & probability03 medical and health sciences0302 clinical medicineMethodsEstadística como AsuntoInvestigación InterdisciplinariaHumans030212 general & internal medicine0101 mathematicsEstatística como AssuntoModels StatisticalStatistics as topiclcsh:Public aspects of medicinelcsh:RPublic Health Environmental and Occupational HealthReproducibility of Resultslcsh:RA1-1270Reference StandardsResearch DesignRegression AnalysisPublic Health
researchProduct

Acute myeloid leukemia (AML)-reactive cytotoxic T lymphocyte clones rapidly expanded from CD8(+) CD62L((high)+) T cells of healthy donors prevent AML…

2008

Objective Current in vitro techniques for isolating leukemia-reactive cytotoxic T lymphocytes (CTLs) from healthy donors are of relatively low efficiency and yield responder populations with unknown biological significance. This study aimed at the development of a more reliable approach, allowing generation and expansion of acute myeloid leukemia (AML)-reactive CTLs using primary in vitro stimulation. Materials and Methods We established allogeneic mini-mixed lymphocyte-leukemia cultures (mini-MLLCs) by stimulating donor CD8 + T cells with human leukocyte antigen (HLA) class I–matched AML blasts in microtiter plates. Before culture, CD8 + T cells were separated into CD62L (high)+ and CD62L …

Cancer ResearchMyeloidGenes MHC Class Ichemical and pharmacologic phenomenaHuman leukocyte antigenMice SCIDBiologyCD8-Positive T-LymphocytesMiceImmune systemMice Inbred NODhemic and lymphatic diseasesGeneticsmedicineCytotoxic T cellAnimalsHumansL-SelectinMolecular BiologyAllelesCells CulturedMice KnockoutMyeloid leukemiahemic and immune systemsCell BiologyHematologyReference Standardsmedicine.diseaseCytotoxicity Tests ImmunologicClone CellsCTL*LeukemiaLeukemia Myeloid Acutemedicine.anatomical_structureImmunologyCD8Neoplasm TransplantationInterleukin Receptor Common gamma SubunitT-Lymphocytes CytotoxicExperimental hematology
researchProduct

Absolute and relative quantification of RNA modifications via biosynthetic isotopomers

2014

In the resurging field of RNA modifications, quantification is a bottleneck blocking many exciting avenues. With currently over 150 known nucleoside alterations, detection and quantification methods must encompass multiple modifications for a comprehensive profile. LC-MS/MS approaches offer a perspective for comprehensive parallel quantification of all the various modifications found in total RNA of a given organism. By feeding (13)C-glucose as sole carbon source, we have generated a stable isotope-labeled internal standard (SIL-IS) for bacterial RNA, which facilitates relative comparison of all modifications. While conventional SIL-IS approaches require the chemical synthesis of single mod…

Carbon IsotopesTandem Mass SpectrometryEscherichia coli500 Natural sciences and mathematicsMethods OnlineRNANucleosides500 NaturwissenschaftenReference Standards13PseudouridineChromatography LiquidNucleic Acids Research
researchProduct

Microscale synthesis of phosphatidyl-[3H]choline from 1,2-diacylglycerol. Assessment of isomerization by reversed-phase high-performance liquid chrom…

1995

The synthesis of rac-1-palmitoyl-2-oleoylglycero-3-phospho-[3H]choline of high specific activity was carried out on a microscale by making 7 mumol of rac-1-palmitoyl-2-oleoylglycerol react first with an equimolar amount of POCl3 and then of [3H]choline. After purification by thin-layer chromatography and normal-phase high-performance liquid chromatography and normal-phase high-performance liquid chromatography (HPLC), the yield of the synthesis of [3H]phosphatidylcholine (120 microCi/mumol) was 22%. rac-1-Palmitoyl-2-oleoylglycerol was purified before use by reversed-phase HPLC under conditions which were nonisomerizing and allowed the separation of 1,2- and 1,3-isomers of diacylglycerol. E…

Chromatography GasChromatographyOrganic ChemistryStereoisomerismCell BiologyReference StandardsBiochemistryHigh-performance liquid chromatographyDiglycerideschemistry.chemical_compoundchemistryPhosphatidylcholinePhosphatidylcholinesCholineChromatography Thin LayerMethanolAcetonitrileIsomerizationChromatography High Pressure LiquidCholine chlorideDiacylglycerol kinaseLipids
researchProduct

Determination of pyrethroid pesticide residues in fatty materials by solid-matrix dispersion partition, followed by mini-column size-exclusion chroma…

1999

The method studied uses a combination of a solid-matrix dispersion partition (SMDP) followed by high-performance size-exclusion chromatography on a minicolumn (HPmSEC) of 7.8 mm I.D. for the separation of pyrethroid (PYR) residues from fatty material. The solid-matrix dispersion extraction is carried out by absorbing a fat solution onto an Extrelut-3 cartridge (filled with a macroporous diatomaceous material) and extracting the PYR residues with acetonitrile. Up to 1 g of fatty material can be extracted with 15 ml acetonitrile. The small amount (mean +/- S.D. = 12.4 +/- 5.9 mg) of fatty material which is eluted into the acetonitrile is further removed by HPmSEC. PYR pesticide residues are c…

Chromatography GasChromatographyPesticide residueChemistryElutionOrganic ChemistrySize-exclusion chromatographyPesticide ResiduesTralomethrinGeneral MedicineReference StandardsBiochemistryAnalytical ChemistryFatsGel permeation chromatographychemistry.chemical_compoundColumn chromatographyPyrethrinsChromatography GelSolid phase extractionGas chromatographyChromatography High Pressure LiquidJournal of Chromatography A
researchProduct

Determination of organochlorine pesticide residues in honey from the central zone of Portugal and the Valencian community of Spain

2004

In this study nine organochlorine pesticide residues ([alpha]-, [beta]-, and [gamma]-hexachlorocyclohexane (HCH), hexachlorobenzene (HCB), aldrin, p,p'-DDE, p,p'-DDD, o,p'-DDT, and p,p'-DDT) in forty nine samples of honey collected from markets of Portugal and Spain during 2001 and 2002, respectively, were evaluated. For this evaluation, three analytical procedures were studied. The analytical procedure, based on LLE extraction with ethyl acetate followed by gas chromatography-electron-capture detection (GC-ECD) for quantification, and mass spectrometry (GC-MS) for confirmation, has been selected. Recoveries of spiked samples ranged from 68%, for [beta]-HCH, and 126% for p,p'-DDT, for forti…

Chromatography GasEthyl acetateOrganochlorineBiochemistryGas Chromatography-Mass SpectrometryAnalytical Chemistrychemistry.chemical_compoundElectrochemistryHydrocarbons ChlorinatedAldrinForty NinePesticidesDetection limitChromatographyPortugalPesticide residueOrganic ChemistryPesticide ResiduesReproducibility of ResultsHoneyGeneral MedicineHexachlorobenzeneReference StandardsPesticidechemistrySpainGas chromatography–mass spectrometryJournal of Chromatography A
researchProduct

Processing of Generator-Produced 68Ga for Medical Application

2007

The (68)Ge/(68)Ga generator provides an excellent source of positron-emitting (68)Ga. However, newly available "ionic" (68)Ge/(68)Ga radionuclide generators are not necessarily optimized for the synthesis of (68)Ga-labeled radiopharmaceuticals. The eluates have rather large volumes, a high concentration of H(+) (pH of 1), a breakthrough of (68)Ge, increasing with time or frequency of use, and impurities such as stable Zn(II) generated by the decay of (68)Ga, Ti(IV) as a constituent of the column material, and Fe(III) as a general impurity.We have developed an efficient route for the processing of generator-derived (68)Ga eluates, including the labeling and purification of biomolecules. Prec…

ChromatographyAqueous solutionElutionIon chromatographyGallium RadioisotopesFraction (chemistry)Hydrochloric acidEquipment DesignReference StandardsEquipment Failure Analysischemistry.chemical_compoundColumn chromatographychemistryGermanyIsotope LabelingAcetoneRadiology Nuclear Medicine and imagingRadionuclide GeneratorJournal of Nuclear Medicine
researchProduct

Univariate method for background correction in liquid chromatography–Fourier transform infrared spectrometry

2007

An univariate method is proposed for background correction in on-line gradient liquid chromatography-Fourier transform infrared (LC-FTIR) spectrometry using acetonitrile:water as mobile phase components. The method is based on the calculation of the ratio of absorbances (AR) at two characteristic wavenumbers for each spectrum. This parameter is subsequently used to locate the most appropriated eluent spectrum within a reference spectra matrix (RSM) to be subtracted from each spectrum included in the sample chromatogram. To correct minor changes in eluent spectra intensity during the elution of analytes, a correction factor (Kf), defined as the ratio of the absorbance of the sample and the s…

ChromatographyChemistryElutionOrganic ChemistryAnalytical chemistryInfrared spectroscopyGeneral MedicineReference StandardsMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)ChemometricsAbsorbanceDiuronSpectroscopy Fourier Transform InfraredAtrazineFourier transform infrared spectroscopyChromatography LiquidJournal of Chromatography A
researchProduct

Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by high-performance liquid chromatography wi…

2002

A method for the extraction of clenbuterol from calf urine samples using a molecularly imprinted polymer (MIP) has been developed. The aim was that the final extracts from the MIP should allow quantitation of clenbuterol down to 0.5 ng/mL urine using HPLC with UV detection. The MIP was produced using brombuterol as a template and the selectivity of the MIP, for clenbuterol, was tested against a non-imprinted polymer (produced without template) and was found to be high. After loading of 5 mL diluted centrifuged urine, selective binding was established in acetonitrile-acetic acid (98:2). For further elution of interferences, 0.5 M ammonium acetate buffer pH 5 and 70% acetonitrile in water was…

ChromatographyChemistryElutionOrganic ChemistryExtraction (chemistry)Molecularly imprinted polymerReproducibility of ResultsGeneral MedicineReversed-phase chromatographyReference StandardsSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryClenbuterolmedicineAnimalsCattleClenbuterolSpectrophotometry UltravioletSample preparationSolid phase extractionAdrenergic alpha-AgonistsChromatography High Pressure Liquidmedicine.drugJournal of Chromatography A
researchProduct

Determination of busulfan in human plasma using high-performance liquid chromatography with pre-column derivatization and fluorescence detection.

1999

A rapid, sensitive and reproducible high-performance liquid chromatographic assay for busulfan in human plasma was developed. After extraction of plasma samples with acetonitrile and methylene chloride, busulfan and the internal standard [1,5-bis(methanesulfonyloxy)pentane] were derivatized with 8-mercaptoquinoline to yield fluorescent compounds which were detected with a fluorescence detector equipped with filters of 360 nm (excitation) and 425 nm (emission). Calibration graphs showed a linear correlation (r>0.9990) over the concentration range of 20-2000 ng/ml. The recovery of busulfan from plasma standards was 70+/-5%. The detection and quantification limits for busulfan in plasma sample…

ChromatographyChemistryExtraction (chemistry)Reproducibility of ResultsGeneral ChemistryReference StandardsHigh-performance liquid chromatographyFluorescenceSensitivity and SpecificityFluorescence spectroscopyPentanechemistry.chemical_compoundSpectrometry FluorescenceCalibrationmedicineHumansDerivatizationQuantitative analysis (chemistry)Antineoplastic Agents AlkylatingBusulfanBusulfanChromatography High Pressure Liquidmedicine.drugJournal of chromatography. B, Biomedical sciences and applications
researchProduct