Curvature of iris profile in spectral domain optical coherence tomography and dependency to refraction, age and pupil size - the MIPH Eye&Health …
2016
Purpose Optical coherence tomography (OCT) of the anterior segment allows quantitative analysis of the geometry of the iris. We performed spectral domain OCT examinations in healthy emmetropic, hyperopic and myopic subjects to investigate iris curvature and its associations. Methods In a cross-sectional study, out of 4617 eyes (2309 subjects) those with refractive errors of +3 dioptres were identified by objective refraction. The iris was examined using the anterior segment mode of a spectral domain 3D OCT-2000 (Topcon Inc., Japan) in the temporal meridian, and OCT scans were investigated with respect to presence and amount of convex and concave iris configuration. Ninety-three eyes of 50 s…
Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer
2018
Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…
Interchangeability among five devices that measure anterior eye distances.
2014
The aim was to study the interchangeability of various devices that measure anterior chamber depth (ACD) and white-to-white (WTW) distance.Eighty right eyes of eighty patients aged 20 to 40 years were included. Their spherical equivalent ranged from -4.25 to +1.00 dioptres. Each eye's ACD and the WTW distance were measured using the following devices: a Castroviejo surgical calliper, CA-200F Corneal Analyser, Orbscan II, Pentacam HR and IOLMaster 500.The Pentacam HR measured significantly greater ACD (p0.01) than the other two devices, whereas IOLMaster 500 and Orbscan II yielded comparable (p0.01) distances. Nonetheless, in every device comparison, the mean difference was within clinically…
Precision of a commercial hartmann-shack aberrometer: limits of total wavefront laser vision correction.
2012
Purpose To assess the intrasession and intersession precision of higher-order aberrations (HOAs) measured using a commercial Hartmann-Shack wavefront sensor (Zywave; Bausch & Lomb) in refractive surgery candidates. Design Prospective, experimental study of a device. Methods To analyze intrasession repeatability, 1 experienced examiner measured 30 healthy eyes 5 times successively. To study intersession reproducibility, the same clinician obtained measurements from another 30 eyes in 2 consecutive sessions at the same time of day 1 week apart. Results For intrasession repeatability, excellent intraclass correlation coefficients (ICCs) were obtained for total ocular aberrations, total HOAs, a…
Posterior chamber phakic intraocular lenses to correct high myopia: A comparative study between Staar and Adatomed models
2001
ABSTRACT PURPOSE: To determine the feasibility of using posterior chamber phakic intraocular lenses (PIOLs) to treat high myopia, comparing two different models, Staar and Adatomed. METHODS: Twenty-four eyes from 12 patients were studied prospectively. A phakic Staar IOL was implanted in one eye of each patient, and the other eye received a phakic Adatomed IOL. Patients with uveitis or ocular trauma prior to ocular surgery, diabetic retinopathy, or capsular pseudoexfoliation were excluded. The mean preoperative spherical equivalent refraction was -16.00 ± 5.05 D for the Staar group and -15.39 ± 2.83 D for the Adatomed group. Average follow-up was 32.4 months (range, 19 to 46 mo) for the Ada…
Intraocular pressure after excimer laser myopic refractive surgery
2001
The aim of this study was to determine whether intraocular pressure (IOP), as measured by Goldmann applanation or non-contact tonometry, shows systematic changes in patients who have undergone photorefractive keratectomy (PRK) or laser in situ keratomileusis (LASIK). IOP was measured by central Goldmann and non-contact tonometry in 54 patients pre and post-PRK, and in 43 patients pre- and post-LASIK. An interval of 12 months was allowed after surgery. Patients were selected to have one of four specific initial values of refractive error (-2.5, -5.0, -7.5 and -10.0 D). Fellow unoperated eyes were used as controls. A paired Student's t-test and a one-way ANOVA test were used for statistical a…
Subjective Satisfaction in Long-term Orthokeratology Patients
2013
Purpose: To AU3 evaluate the subjective satisfaction in visual stability, night vision complains, and light distortion phenomena, and also the number of hours and days per week of lens wear, in patients with myopia undergoing orthokeratology (OK) treatment for at least 1 year. Methods: A visual analog scale (VAS) questionnaire containing 18 items was administered to 44 patients, 29 women and 15 men (mean age, 24.39 6 9.11 years), with a baseline spherical equivalent refractive error of 22.40 6 0.94 diopters and astigmatism up to 20.5 diopters. Average treatment period by the time of data collection was 19 6 7 months. Patients rated their satisfaction with the correction, with complaints of …
Light distortion of soft multifocal contact lenses with different pupil size and shape
2020
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…
Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation
2009
PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …
Nine Loci for Ocular Axial Length Identified through Genome-wide Association Studies, Including Shared Loci with Refractive Error
2013
Refractive errors are common eye disorders of public health importance worldwide. Ocular axial length (AL) is the major determinant of refraction and thus of myopia and hyperopia. We conducted a meta-analysis of genome-wide association studies for AL, combining 12,531 Europeans and 8,216 Asians. We identified eight genome-wide significant loci for AL (RSPO1, C3orf26, LAMA2, GJD2, ZNRF3, CD55, MIP, and ALPPL2) and confirmed one previously reported AL locus (ZC3H11B). Of the nine loci, five (LAMA2, GJD2, CD55, ALPPL2, and ZC3H11B) were associated with refraction in 18 independent cohorts (n = 23,591). Differential gene expression was observed for these loci in minus-lens-induced myopia mouse …