Resting-State Functional Connectome in Patients with Brain Tumors Before and After Surgical Resection
2020
Purpose: High-grade glioma surgery has evolved around the principal belief that a safe maximal tumor resection improves symptoms, quality of life, and survival. Mapping brain function has been recently improved by resting-state functional magnetic resonance imaging (rest-fMRI), a novel imaging technique that explores networks connectivity at “rest.” Methods: This prospective study analyzed 10 patients with high-grade glioma in whom rest-fMRI connectivity was assessed both in single-subject and in group analysis before and after surgery. Seed-based functional connectivity analysis was performed with CONN toolbox. Network identification focused on 8 major functional connectivity networks. A v…
Single region of interest versus multislice T2* MRI approach for the quantification of hepatic iron overload.
2011
Purpose To evaluate the effectiveness of the single ROI approach for the detection of hepatic iron burden in thalassemia major (TM) patients in respect to a whole liver measurement. Materials and Methods Five transverse hepatic slices were acquired by a T2* gradient-echo sequence in 101 TM patients and 20 healthy subjects. The T2* value was calculated in a single region of interest (ROI) defined in the medium-hepatic slice. Moreover, the T2* value was extracted on each of the eight ROIs defined in the functionally independent segments. The mean hepatic T2* value was calculated. Results For patients, the mean T2* values over segments VII and VIII were significantly lower. This pattern was su…
Improved T2* assessment in liver iron overload by magnetic resonance imaging.
2009
In the clinical MRI practice, it is common to assess liver iron overload by T2* multi-echo gradient-echo images. However, there is no full consensus about the best image analysis approach for the T2* measurements. The currently used methods involve manual drawing of a region of interest (ROI) within MR images of the liver. Evaluation of a representative liver T2* value is done by fitting an appropriate model to the signal decay within the ROIs vs. the echo time. The resulting T2* value may depend on both ROI placement and choice of the signal decay model. The aim of this study was to understand how the choice of the analysis methodology may affect the accuracy of T2* measurements. A softwar…
Feasibility, reproducibility, and reliability for the T*2 iron evaluation at 3 T in comparison with 1.5 T
2012
This study aimed to determine the feasibility, reproducibility, and reliability of the multiecho T * 2 Magnetic resonance imaging technique at 3 T for myocardial and liver iron burden quantification and the relationship between T * 2 values at 3 and 1.5 T. Thirty-eight transfusion-dependent patients and 20 healthy subjects were studied. Cardiac segmental and global T * 2 values were calculated after developing a correction map to compensate the artifactual T * 2 variations. The hepatic T * 2 value was determined over a region of interest. The intraoperator and interoperator reproducibility for T * 2 measurements at 3 T was good. A linear relationship was found between patients' R (1000/T * …
Effects of Interobserver Variability on 2D and 3D CT- and MRI-Based Texture Feature Reproducibility of Cartilaginous Bone Tumors
2021
AbstractThis study aims to investigate the influence of interobserver manual segmentation variability on the reproducibility of 2D and 3D unenhanced computed tomography (CT)- and magnetic resonance imaging (MRI)-based texture analysis. Thirty patients with cartilaginous bone tumors (10 enchondromas, 10 atypical cartilaginous tumors, 10 chondrosarcomas) were retrospectively included. Three radiologists independently performed manual contour-focused segmentation on unenhanced CT and T1-weighted and T2-weighted MRI by drawing both a 2D region of interest (ROI) on the slice showing the largest tumor area and a 3D ROI including the whole tumor volume. Additionally, a marginal erosion was applied…
Comparison of ultrasound and bone mineral density assessment of the calcaneus with different regions of interest in healthy early menopausal women.
1998
This study investigated the effect of different sized regions of interest (ROIs) on quantitative ultrasound (QUS) variables of the calcaneus. The effect on QUS of using a fixed ROI as opposed to an ROI adjusted for foot length was also assessed. Eighty Caucasian women, aged 50-57 yr (mean 53 +/- 2) who were healthy and within 0. 5-5 yr of the onset of menopause participated in this study. Using the QUS-1(trade mark) Ultrasonometer (Metra Biosystems, Mountain View, CA), we assessed broadband ultrasound attenuation ([BUA] and UBI-4, dB/MHz), the average transit time through the heel ([TTH], mus) and a multiple-factor index (UBI-4T = UBI-4/TTH, dB/[MHz. mus]). The QUS measurement results were …
Automatic Calibration of an Industrial RGB-D Camera Network Using Retroreflective Fiducial Markers
2019
This paper describes a non-invasive, automatic, and robust method for calibrating a scalable RGB-D sensor network based on retroreflective ArUco markers and the iterative closest point (ICP) scheme. We demonstrate the system by calibrating a sensor network comprised of six sensor nodes positioned in a relatively large industrial robot cell with an approximate size of 10 m × 10 m × 4 m . Here, the automatic calibration achieved an average Euclidean error of 3 c m at distances up to 9.45 m . To achieve robustness, we apply several innovative techniques: Firstly, we mitigate the ambiguity problem that occurs when detecting a marker at long range or low resolution by comparing the…
Enhancing TIR Image Resolution via Bayesian Smoothing for IRRISAT Irrigation Management Project
2013
Accurate estimation of physical quantities depends on the availability of High Resolution (HR) observations of the Earth surface. However, due to the unavoidable tradeoff between spatial and time resolution, the acquisition instants of HR data hardly coincides with those required by the estimation algorithms. A possible solution consists in constructing a synthetic HR observation at a given time k by exploiting Low Resolution (LR) and HR data acquired at different instants. In this work we recast this issue as a smoothing problem, thus focusing on cases in which observations acquired both before and after time k are available. The proposed approach is validated on a region of interest for t…
Comparison of region of interest segmentation methods for video-based heart rate measurements
2018
International audience; Conventional contact photoplethysmography (PPG) sensors are not suitable in situations of skin damage or when unconstrained movement is required. As a consequence, remote photoplethysmography (rPPG) has recently emerged because it provides remote physiological measurements without expensive hardware and improves comfort for long-term monitoring. RPPG estimation methods use the spatially averaged RGB values of pixels in a Region Of Interest (ROI) to generate a temporal RGB signal. The selection of ROI is a critical first step to obtain reliable pulse signals and must contain as many skin pixels as possible with a low percentage of non-skin pixels. In this paper, we ex…
Full field of view super-resolution imaging via two static masks
2008
The usage of two static gratings for obtaining super resolved imaging dates back to the work by Bachl and Lukosz in 1967. However, in that approach, a severe reduction in the field of view was the necessary condition for improving the resolution. In this paper we present two approaches that are also based upon two static gratings but without the need to sacrifice in the field of view. The key idea for not paying with the field of view is performed in two ways: First, by using white light illumination that averages the ghost images obtained outside the region of interest since the positions of those images are wavelength dependent. Second, by using two random functions for the encoding and t…