Search results for "reliability"

showing 10 items of 1563 documents

Uncertainty assessment of a model for biological nitrogen and phosphorus removal: Application to a large wastewater treatment plant

2012

Abstract In the last few years, the use of mathematical models in WasteWater Treatment Plant (WWTP) processes has become a common way to predict WWTP behaviour. However, mathematical models generally demand advanced input for their implementation that must be evaluated by an extensive data-gathering campaign, which cannot always be carried out. This fact, together with the intrinsic complexity of the model structure, leads to model results that may be very uncertain. Quantification of the uncertainty is imperative. However, despite the importance of uncertainty quantification, only few studies have been carried out in the wastewater treatment field, and those studies only included a few of …

EngineeringSettore ICAR/03 - Ingegneria Sanitaria-AmbientaleMathematical modelbusiness.industryNitrogen phosphorus removalMonte Carlo methodUncertainty analysiEnvironmental engineeringWastewater modellingGeophysicsGeochemistry and PetrologyData qualityCalibrationProbability distributionBiochemical engineeringUncertainty quantificationGLUEbusinessActivated-sludge modelReliability (statistics)Uncertainty analysisPhysics and Chemistry of the Earth, Parts A/B/C
researchProduct

A procedure to calculate the five-parameter model of crystalline silicon photovoltaic modules on the basis of the tabular performance data

2013

Abstract Only few manufactures provide the wide set of graphical data that are necessary to use high performance predictive tools for PV systems. On the other hand, reliable graphical data require accurate laboratory measurements that increase manufacturing costs. For this reason PV system designers have to choose between the use of cheap PV modules, lacking in technical data, and the reliable energy predictions that are possible only if the current–voltage characteristics are provided by the PV module manufacturers. This paper describes the procedure to evaluate the parameters of a one-diode equivalent circuit able to accurately represent the electrical behaviour of a PV panel by means of …

EngineeringSettore ING-IND/11 - Fisica Tecnica AmbientaleBasis (linear algebra)business.industryMechanical EngineeringReliability (computer networking)Photovoltaic systemBuilding and ConstructionVisual Basic for ApplicationsManagement Monitoring Policy and LawReliability engineeringSet (abstract data type)General EnergyPhotovoltaic modules; Five-parameter model; I–V characteristics; Solar energyEquivalent circuitCrystalline siliconbusinessEnergy (signal processing)Applied Energy
researchProduct

Sensitivity analysis to quantify uncertainty in Life Cycle Assessment: The case study of an Italian tile

2011

Abstract The results of a Life Cycle Assessment (LCA) study can be affected by several uncertainty sources, mainly due to the methodological choices, the initial assumptions, i.e. allocation rules, system boundaries and impact assessment methods, and the quality of the available data. Then, the experts should estimate the extent of the above-mentioned sources of uncertainty for improving the reliability and the representativeness of the obtained eco-profiles. To estimate the uncertainty is necessary to obtain reliable, transparent and representative LCA results and to correctly support decision-makers in the selection of different product or process options. The following paper starts from …

EngineeringSettore ING-IND/11 - Fisica Tecnica AmbientaleOperations researchRenewable Energy Sustainability and the Environmentbusiness.industryImpact assessmentProcess (engineering)media_common.quotation_subjectLife Cycle Analysis (LCA) Sensitivity analysis Uncertainty Tiles Energy Environmental impactRepresentativeness heuristicReliability engineeringEnvironmental impact assessmentQuality (business)Sensitivity (control systems)businessLife-cycle assessmentReliability (statistics)media_common
researchProduct

Is the transfer function method reliable in a European building context? A theoretical analysis and a case study in the South of Italy

2005

Abstract The available tools for dynamic simulation of the buildings thermal behaviour are manifold, and the most modern ones, known as TRNSYS, are founded upon the use of the Z-transform (ZT) set also called transfer function method (TFM). The transfer function method (TFM), recommended by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), is one of the most modern tools available to solve heat transfer problems in building envelopes and environments. TFM utilises Z-transforms to solve the equation system that describes the heat transfer in a multi-layered wall. Due to an analogy with an electric circuit, it is possible to write the equation system in a mat…

EngineeringSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industryEnergy Engineering and Power TechnologyMechanical engineeringContext (language use)Control engineeringTRNSYSTransfer functionIndustrial and Manufacturing EngineeringDynamic simulationStep responseHeat transferASHRAE 90.1businessCTF coefficients ASHRAE heat balance method Thermal building simulationReliability (statistics)
researchProduct

Review of the energy and economic parameters involved in the effectiveness of grid-connected PV systems installed in multi-storey buildings

2014

Abstract The assessment of PV energy in an urban context is extremely complex because many factors have to be considered. Moreover, when the purpose is calculating the realistic amount of the electricity demand of a city that can be covered by the photovoltaic generation, it is necessary to estimate the number of photovoltaic systems whose installation is economically advantageous. Such a topic requires an economic analysis, which is affected by the number of energy and economic parameters involved and the values assigned to them to perform calculations. Some parameters are perfectly known and unvarying, like the paid incentives. Adversely, some parameters, like the efficiency degradation o…

EngineeringSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industryMechanical EngineeringPhotovoltaic systemBuilding and ConstructionManagement Monitoring Policy and LawGridCivil engineeringEnergy policyReliability engineeringEconomic parametersGeneral EnergyIncentiveGrid-connected photovoltaic power systemEconomic analysisProfitability indexbusinessPhotovoltaic Grid-connected PV systems Energy parameters Economic parameters
researchProduct

Comparing different control strategies for indoor thermal comfort aimed at the evaluation of the energy cost of quality of building

2010

Abstract The rapid improvement in the standard of living requires more detailed and sophisticated methods of evaluating comfort conditions. But, maintaining thermal comfort conditions in confined environments may require complex regulation procedures and the proper management of heating, ventilating and air conditioning (HVAC) systems. In turn, the requirements for indoor thermal comfort do not necessarily coincide with those of energy saving purposes, which in the last years are becoming a crucial issue owing to the enactment of the European Energy Performance of Buildings Directive (EPBD). The aim of this work is to compare different indoor control thermal comfort strategies in view of th…

EngineeringSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industrymedia_common.quotation_subjectWork (physics)Energy Engineering and Power TechnologyPID controllerThermal comfortControl engineeringIndustrial and Manufacturing EngineeringReliability engineeringControl theoryAir conditioningHVACQuality (business)indoor thermal comfort quality building energy performancebusinessEnergy (signal processing)media_commonApplied Thermal Engineering
researchProduct

Seismic Performance of Masonry Infilled RC Structures via N2 Pushover Assessment Procedures: Outcomes under Different Modeling Hypotheses of a Case S…

2016

The assessment of the capacity of RC masonry infilled RC structures constitutes nowadays a still debated issue. Pushover based procedures for the evaluation of seismic performance, such as N2 method, are largely used in practice and in force in several technical codes. The latter has proved to be reliable for a large number of structural typologies, however in the case of infilled frames, the choices made on the modelling strategy may radically modify the outcomes observable from the capacity curves and the consequent performance levels achievable. In the paper, the extent of different modelling choices on the results of the application of N2 procedure is investigated by the deep analysis o…

EngineeringShear ActionPushoverbusiness.industryN2General MedicineStructural engineeringMasonryInfilled FramesReinforced concreteInfilled framesShear (sheet metal)reinforced concrete shear action infilled frames masonry n2 pushoverMasonrybusinessInfilled Frames Masonry N2 Pushover Reinforced Concrete Shear ActionReinforced ConcreteReliability (statistics)Applied Mechanics and Materials
researchProduct

Research Toward The Optical Equipment For An Autonomous Robot For TviV Environment

1989

The paper consists of three major parts: basic technical problems in very high power/megavolt environment, signal processing and mechanical equipment for this environment, construction of a sensor equipped robot for this environment. The first part contains mainly metrological confinements and reliability considerations for the optical, optoelectronic and electronic part of a system. The second part contains mechanics and robotics problems. The result of these two parts is a choice of a system to be realized.

EngineeringSignal processingReliability (semiconductor)business.industryControl systemRobotRoboticsControl engineeringArtificial intelligencebusinessAutonomous robotMechanical equipmentPower (physics)Industrial Inspection
researchProduct

A robust calibration methodology for an On-Board Diagnostic car system

2006

New car models are now by law equipped with on-board diagnostic (OBD) systems aimed at monitoring the state of health of strategic components that ensure low levels of polluting exhaust emissions. During development phases, for each new car model, the OBD system must be finely calibrated. This article presents a robust calibration methodology taking into account sources of variability mainly due to production process, operating, and environmental conditions. The methodology enables us to evaluate the false alarm and failure to detect risks intrinsically related to the adopted calibration. An application concerning an upstream oxygen sensor monitored by the OBD is presented.

EngineeringState of healthCalibration (statistics)business.industrySettore SECS-S/02 - Statistica Per La Ricerca Sperimentale E TecnologicaIndustrial and Manufacturing EngineeringAutomotive engineeringFault detection and isolationOn-board diagnosticsApplications in engineering and industry Fault detection Hypothesis testing On-board diagnostics Robust parameter designUpstream (networking)False alarmSafety Risk Reliability and QualityRobust parameter designbusinessSimulationStatistical hypothesis testing
researchProduct

Reliability Approach to the Design, Construction and Use of Natural Draught Cooling Towers

1989

Structures or structural elements should be designed and constructed such they are suited to their intended use. But principles for the design, construction, use and maintenace are changing evolutionary. It is due to fundamental research and the progress in technology.

EngineeringStructural loadbusiness.industrySteering systemDeep beamCooling towerbusinessCivil engineeringReliability (statistics)Natural (archaeology)
researchProduct