Search results for "reparation"
showing 10 items of 944 documents
Pressurized liquid extraction combined with capillary electrophoresis–mass spectrometry as an improved methodology for the determination of sulfonami…
2007
A new analytical method, based on capillary electrophoresis and tandem mass spectrometry (CE-MS2), is proposed and validated for the identification and simultaneous quantification of 12 sulfonamides (SAs) in pork meat. The studied SAs include sulfathiazole, sulfadiazine, sulfamethoxypyridazine, sulfaguanidine, sulfanilamide, sulfadimethoxyne, sulfapyridine, sulfachloropyridazine, sulfisoxazole, sulfasalazine, sulfabenzamide and sulfadimidine. Different parameters (i.e. separation buffer, sheath liquid, electrospray conditions) were optimized to obtain an adequate CE separation and high MS sensitivity. MS2 experiments using an ion trap as analyzer, operating in the selected reaction monitori…
Chromatographic multivariate quality control of pharmaceuticals giving strongly overlapped peaks based on the chromatogram profile
2004
In the present paper, the simultaneous quantification of two analytes showing strongly overlapped chromatographic peaks (alpha = 1.02), under the assumption that both available equipment and training of the laboratory staff are basic, is studied. A pharmaceutical preparation (Mutabase) containing two drugs of similar physicochemical properties (amitriptyline and perphenazine) is selected as case of study. The assays are carried out under realistic working conditions (i.e. routine testing laboratories). Uncertainty considerations are introduced in the study. A partial least squares model is directly applied to the chromatographic data (with no previous signal transformation) to perform quali…
Enantiomeric quality control of antihistamines in pharmaceuticals by affinity electrokinetic chromatography with human serum albumin as chiral select…
2007
The present paper deals with the enantiomeric separation of six antihistaminic enantiomers by affinity electrokinetic chromatography (AEKC)-partial filling technique using human serum albumin (HSA) as chiral selector. A multivariate optimization approach of the most critical experimental variables in enantioresolution, running pH, HSA concentration and HSA plug length (SPL) was carried out since there are interactions between variables that could not be considered in an univariate optimization. The estimated and experimental resolution values obtained for antihistaminic enantiomers varied from 1.13 (for orphenadrine) to 2.15 (for brompheniramine). The optimum experimental conditions for ena…
Biopartitioning micellar chromatoraphy to predict blood to lung, blood to liver, blood to fat and blood to skin partition coefficients of drugs
2009
[EN] Biopartitioning micellar chromatography (BMC), a mode of micellar liquid chromatography that uses micellar mobile phases of Brij35 in adequate experimental conditions, has demonstrated to be useful in mimicking the drug partitioning process into biological systems. In this paper, the usefulness of BMC for predicting the partition coefficients from blood to lung, blood to liver. blood to fat and blood to skin is demonstrated. PLS2 and multiple linear regression (MLR) models based on BMC retention data are proposed and compared with other ones reported in bibliography. The proposed models present better or similar descriptive and predictive capability. (C) 2008 Elsevier B.V. All rights r…
Molecular topology as a novel approach for drug discovery
2012
Molecular topology (MT) has emerged in recent years as a powerful approach for the in silico generation of new drugs. One key part of MT is that, in the process of drug design/discovery, there is no need for an explicit knowledge of a drug's mechanism of action unlike other drug discovery methods.In this review, the authors introduce the topic by explaining briefly the most common methodology used today in drug design/discovery and address the most important concepts of MT and the methodology followed (QSAR equations, LDA, etc.). Furthermore, the significant results achieved, from this approach, are outlined and discussed.The results outlined herein can be explained by considering that MT r…
A topological substructural approach for the prediction of P-glycoprotein substrates
2006
A topological substructural molecular design approach (TOPS-MODE) has been used to predict whether a given compound is a P-glycoprotein (P-gp) substrate or not. A linear discriminant model was developed to classify a data set of 163 compounds as substrates or nonsubstrates (91 substrates and 72 nonsubstrates). The final model fit the data with sensitivity of 82.42% and specificity of 79.17%, for a final accuracy of 80.98%. The model was validated through the use of an external validation set (40 compounds, 22 substrates and 18 nonsubstrates) with a 77.50% of prediction accuracy; fivefold full cross-validation (removing 40 compounds in each cycle, 80.50% of good prediction) and the predictio…
Modeling the chiral resolution ability of highly sulfated β-cyclodextrin for basic compounds in electrokinetic chromatography
2013
Abstract Despite the fact that extensive research in the field of enantioseparations by capillary electrophoresis has been carried out, it is difficult to predict whether a concrete chiral selector would be useful for the separation of a racemic compound. Hence, several experimental effort is necessary to test the abilities of individual chiral selectors, usually by trial and error procedures. Thus, the enantioseparation of a new racemate becomes a time- and money-consuming task. In this work, the ability of highly sulfated β-cyclodextrin (HS-β-CD) as chiral selector in electrokinetic chromatography (EKC) is modeled for the first time, using exclusively directly-available structural data of…
Blocking of an ion channel by a highly charged drug: Modeling the effects of applied voltage, electrolyte concentration, and drug concentration
2005
We present a simple physical model to estimate the blocked pore probability of an ion channel that can be blocked by a highly charged drug in solution. The model is inspired by recent experimental work on the blocking of the ${\mathrm{PA}}_{63}$ channel, involved in the anthrax toxin infection, by a highly charged drug [Karginov et al. PNAS 102, 15075 (2005)]. The drug binding to the pore is highly specific but the strong dependence of blocking on the applied voltage and electrolyte concentration suggests that long range electrostatic interactions are important. Since basic electrostatic concepts rather than detailed molecular models are considered, the microscopic details of the channel bl…
An effective negative pressure cavitation-microwave assisted extraction for determination of phenolic compounds in P. calliantha H. Andr.
2013
A novel negative pressure and microwave assisted extraction technique (NMAE) was first proposed and applied for extraction of phenolic compounds from pyrola. [C₄MIM]BF₄ aqueous solution was selected as extraction solvent. Optimal extraction conditions were microwave power 700 W, negative pressure -0.07 MPa, temperature 40 °C, liquid-solid ratio 20 : 1, ionic liquid (IL) concentration 0.5 M, extraction time 15 min. The predominance of NMAE was investigated by comparing with microwave-assisted extraction (MAE) and negative pressure cavitation extraction (NPCE) using a first-order kinetics equation. The C∞ values of the target compounds by NMAE were from 0.406 to 5.977 mg g⁻¹ higher than these…
Rapid analysis of effluents generated by the dairy industry for fat determination by preconcentration in nylon membranes and attenuated total reflect…
2014
Abstract This paper describes a new approach for the determination of fat in the effluents generated by the dairy industry which is based on the retention of fat in nylon membranes and measurement of the absorbances on the membrane surface by ATR-IR spectroscopy. Different options have been evaluated for retaining fat in the membranes using milk samples of different origin and fat content. Based on the results obtained, a method is proposed for the determination of fat in effluents which involves the filtration of 1 mL of the samples through 0.45 µm nylon membranes of 13 mm diameter. The fat content is then determined by measuring the absorbance of band at 1745 cm −1 . The proposed method c…