Search results for "reproducibility of results"
showing 10 items of 1838 documents
Alanine blends for ESR measurements of thermal neutron fluence in a mixed radiation field
2007
In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known…
EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD
2004
Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…
Reproducibility of irritant patch test reactions to sodium lauryl sulfate in a double-blind placebo-controlled randomized study using clinical scorin…
1999
Reading of doubtful patch test reactions can be improved by comparing them to defined negative, allergic and irritant controls. For the latter, an irritant patch test is needed that gives sufficiently reproducible results. In our double-blind, placebo-controlled. randomized study, we have analysed the synchronous reproducibility of patch tests with 0%, 0.0625%, 0.125%, 0.25%, 0.5% and 1.0% sodium lauryl sulfate (SLS). Tests and readings were done according to ESCD guidelines. 139 patients (75 women, 64 men) 18 to 77 years old were tested. The % of positive patients as well as the % of reproducible positive reactions increased with rising concentrations of SLS to a maximum of approximately 9…
Reproducibility of Skin Temperature Response after Cold Stress Test Using the Game Ready System: Preliminary Study
2021
The objective of this preliminary study was to determine the reproducibility of lower limbs skin temperature after cold stress test using the Game Ready system. Skin temperature of fourteen participants was measured before and after cold stress test using the Game Ready system and it was repeated the protocol in four times: at 9:00, at 11:00, at 19:00, and at 9:00 h of the posterior day. To assess skin temperature recovery after cold stress test, a logarithmic equation for each region was calculated, and constant (β0) and slope (β1) coefficients were obtained. Intraclass correlation coefficient (ICC), standard error (SE), and within-subject coefficient of variation (CV) were determined. No …
Four color-measuring devices compared with a spectrophotometric reference system
2009
Abstract Objectives The objective of this study was to compare the L*C*h° color coordinates of dental color-measuring devices with those of a spectrophotometric reference system. Methods The International Commission on Illumination (CIE) L*C*h° color coordinates of ceramic samples, matching the colors of the VITA Linearguide, were recorded using four color-measuring devices (VITA Easyshade (A), VITA Easyshade compact (B), Degudent Shadepilot (C), X-Rite Shadevision (D)) and a spectrophotometric reference system under standardized test conditions. The intraclass correlation coefficients, regression lines with coefficients of determination, and mean deviations of the dental color-measuring de…
Screening for inhibitors of HIV gp120-CD4 binding using an enzyme-linked immunoabsorbent assay.
1993
Binding of the HIV-1 major viral surface glycoprotein, gp120, to the major cell receptor, CD4, is essential for HIV infection of the target cell and syncytium formation. An enzyme-linked immunoassay using solid phase CD4 was used to quantitate the binding of HIV-1 gp120 to CD4, and to assess the activity and mechanism of action of putative inhibitors of that reaction. Monoclonal antibodies to the gp120 binding site on CD4 (e.g., Leu3a) blocked gp120 binding, while monoclonal antibodies to other portions of CD4 (e.g. OKT4) did not. Both aurintricarboxylic acid and sulfonated polysaccharides (e.g., dextran sulfate) blocked CD4-gp120 interactions by binding to the CD4 component. Human polyclon…
The effects of ezetimibe on LDL-cholesterol: quantitative or qualitative changes ?
2009
Ezetimibe represents the first of a new class of agents, the cholesterol absorption inhibitors, able to reduce low-density lipoproteins (LDL)-cholesterol by 15-25% from baseline in monotherapy and on top of statins and fibrates. To-date all the data regarding the efficacy of ezetimibe comes from the studies of its lipid-lowering power. Yet, recent findings from the ENHANCE study on atherosclerosis progression showed that the addition of ezetimibe to simvastatin in patients with heterozygous familial hypercholesterolemia did not affect the mean change in carotid intima-media thickness, although a significant reduction in LDL-cholesterol levels was present. Therefore, we cannot exclude that e…
Reproducibility and validity of ambulatory blood pressure monitoring in children.
2002
During the past several years ambulatory blood pressure monitoring (ABPM) has been introduced into the study of hypertension and has become a useful tool in making clinical decisions. The ABPM improves the reproducibility of the estimates of a subject's casual blood pressure (BP) both in normotensive and in hypertensive subjects, independent of age. The advantages of ambulatory BP (ABP) over its office counterpart have been studied in children to observe the relationship between BP measurement and early markers of organ damage. In different groups of subjects that have included normotensives, essential hypertensives, renal transplant recipients, or patients with repair of an aortic coarctat…
Ambulatory blood pressure monitoring is ready to replace clinic blood pressure in the diagnosis of hypertension: con side of the argument.
2014
The San Francisco experience with Perloff and Sokolow was the starting point for the clinical application of ambulatory blood pressure (ABP) measurement. Using a semiautomatic device, the superiority of ABP to office measurement was demonstrated in the relationship with hypertension-induced organ damage1 and in the risk for cardiovascular events.2 This seminal study impelled an issue with the largest production and impact in the field of hypertension in recent decades, boosting research and having an enormous influence on daily clinical practice. Initially restricted to specialized clinics, ABP monitoring (ABPM) has largely expanded to primary care in many countries. Similarly, scientific p…
Role of virtopsy in the post-mortem diagnosis of drowning.
2014
Purpose: Due to admitted limits of autopsy-based studies in the diagnosis of drowning, virtopsy is considered the new imaging horizon in these post-mortem studies. The aim of our study was to evaluate the role of virtopsy performed through computed tomography (CT) in the forensic diagnosis of drowning. Materials and methods: We retrospectively examined the CT data of four cadavers recovered from sea water and suspected to have died by drowning. Each patient underwent a full-body post-mortem CT scan, and then a traditional autopsy. Conclusion: To date, there are no autopsy findings pathognomonic of drowning. This study proves that virtopsy is a useful tool in the diagnosis of drowning in tha…