Search results for "resolution."
showing 10 items of 1825 documents
Coupled retrieval of aerosol optical thickness, columnar water vapor and surface reflectance maps from ENVISAT/MERIS data over land
2008
An algorithm for the derivation of atmospheric parameters and surface reflectance data from MEdium Resolution Imaging Specrometer Instrument (MERIS) on board ENVIronmental SATellite (ENVISAT) images has been developed. Geo-rectified aerosol optical thickness (AOT), columnar water vapor (CWV) and spectral surface reflectance maps are generated from MERIS Level-1b data over land. The algorithm has been implemented so that AOT, CWV and reflectance products are provided on an operational manner, making no use of ancillary parameters apart from those attached to MERIS products. For this reason, it has been named Self-Contained Atmospheric Parameters Estimation from MERIS data (SCAPE-M). The fund…
Spectral calibration and atmospheric correction of ultra-fine spectral and spatial resolution remote sensing data. Application to CASI-1500 data
2007
Imaging spectrometers operating in the solar spectrum measure the upwelling reflected solar radiation, and are an important tool in the bio/geochemical characterization of the Earth system. Surface reflectance is usually the starting point for the retrieval of biophysical parameters from remote measurements. Reliable radiometric and spectral calibrations and accurate atmospheric correction are mandatory in the interpretation of the surface reflectance. A complete surface reflectance retrieval scheme specifically designed for ultra-fine spectral resolution (bandwidth from 10 to 2 nm) and spatial resolution (pixel size less than 10 m) imaging spectrometers is presented in this work. The asses…
Reduction of Convective Low-Frequency Noise in Thermal Lens Spectrometry
1990
The construction and optimization of a thermal lens spectrometer with coaxial pump/probe configuration is reported. The low-frequency noise of convective origin is studied in detail, and it is demonstrated that a horizontal slit, instead of a pinhole, can be used as a simple way of reducing the noise to a negligible level without losing sensitivity.
Direct infusion mass spectrometry as a fingerprint of protein-binding media used in works of art
2005
A direct infusion mass spectrometry method for the characterization of proteinaceous glues from binding media used in pictorial works of art prior to conservation or restoration treatment is proposed. Amino acids are released by acid hydrolysis and dissolved in a mixture of acidic water and ethanol. This mixture is directly infused into a mass spectrometer without any derivatization. The mass spectrometer is operated in positive ion electrospray mode (ESI-MS) to yield [M+H]+ ions for the amino acids. Relative amounts of each amino acid are calculated for each protein (beef and porcine gelatines, albumin, casein and egg). The analyzed proteins were satisfactorily distinguished. The method is…
A preliminary assessment of a detailed two stream short-wave narrow-band model using spectral radiation measurements
1997
Abstract A data bank of measurements of global, direct and diffuse solar spectral irradiances at ground level for clear skies has been compiled for Valencia (Spain) dating back to December 1992. The measurements were made with a commercial Li-cor 1800 spectroradiometer with a range of 300–1100 nm and a spectral resolution of 6 nm. A preliminary comparative assessment has been carried out between the experimental data and model data. The chosen model was a detailed narrow-band model (208 spectral intervals from 0.2 to 4 μm) developed at the “Laboratoire d'Optique Atmospherique (LOA)” of the University of Lille (France). This plane-parallel multilayer model uses a two-flux method to solve the…
Single-Hemisphere Photoelectron Momentum Microscope With Time-of-Flight Recording
2020
Photoelectron momentum microscopy is an emerging powerful method for angle-resolved photoelectron spectroscopy (ARPES), especially in combination with imaging spin filters. These instruments record kx-ky images, typically exceeding a full Brillouin zone. As energy filters double-hemispherical or time-of-flight (ToF) devices are in use. Here we present a new approach for momentum mapping of the full half-space, based on a single hemispherical analyzer (path radius 225 mm). Excitation by an unfocused He lamp yielded an energy resolution of 7.7 meV. The performance is demonstrated by k-imaging of quantum-well states in Au and Xe multilayers. The alpha-square-aberration term (alpha: entrance an…
Deconvolution of XPS spectra
1991
The resolution of XPS spectra is limited mainly by instrumental parameters like the spectral line width of the exciting X-ray source and the finite energy resolution of the electron analyzer. If the line broadening functions resulting from the instrumental setup can be estimated and expressed by a spectrometer function, a mathematical recalculation of the intrinsic signal is possible by deconvolution. With the method presented in this paper, a resolution enhancement by a factor of 3 can be obtained. Measured spectra of physically correlated spin orbit doublets have been deconvoluted, and it is shown, that the intensity ratios and the positions are comparable with results obtained by highly …
The airway response to deep inspirations decreases with COPD severity and is associated with airway distensibility assessed by computed tomography.
2008
In patients with mild chronic obstructive pulmonary disease (COPD), the effect of deep inspirations (DIs) to reverse methacholine-induced bronchoconstriction is largely attenuated. In this study, we tested the hypothesis that the effectiveness of DI is reduced with increasing disease severity and that this is associated with a reduction in the ability of DI to distend the airways. Fifteen subjects [Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage I–II: n = 7; GOLD stage III–IV: n = 8] underwent methacholine bronchoprovocation in the absence of DI, followed by DI. The effectiveness of DI was assessed by their ability to improve inspiratory vital capacity and forced expira…
Funktionelle Bildgebung der Lunge mit gasförmigem Kontrastmittel: ³Helium-Magnetresonanztomographie
2005
Current imaging methods of the lung concentrate on morphology as well as on the depiction of the pulmonary parenchyma. The need of an advanced and more subtle imaging technology compared to conventional radiography is met by computed topography as the method of choice. Nevertheless, computed tomography yields very limited functional information. This is to be derived from arterial blood gas analysis, spirometry and body plethysmography. These methods, however, lack the scope for regional allocation of any pathology. Magnetic resonance imaging of the lung has been advanced by the use of hyperpolarised (3)Helium as an inhaled gaseous contrast agent. The inhalation of the gas provides function…
Performance of Radiomics Features in the Quantification of Idiopathic Pulmonary Fibrosis from HRCT.
2020
Background: Our study assesses the diagnostic value of different features extracted from high resolution computed tomography (HRCT) images of patients with idiopathic pulmonary fibrosis. These features are investigated over a range of HRCT lung volume measurements (in Hounsfield Units) for which no prior study has yet been published. In particular, we provide a comparison of their diagnostic value at different Hounsfield Unit (HU) thresholds, including corresponding pulmonary functional tests. Methods: We consider thirty-two patients retrospectively for whom both HRCT examinations and spirometry tests were available. First, we analyse the HRCT histogram to extract quantitative lung fibrosis…