Search results for "result"
showing 10 items of 2426 documents
European Sero-Epidemiology Network: standardisation of the assay results for pertussis
2003
A standardisation process was developed in order to compare and harmonize serological results of pertussis toxin (PT) antibody measurements performed by laboratories using different technical procedures for detection. This involved the development of a common panel, of sera by a designed reference centre, the distribution of the panel to each participating laboratory for testing with their routine methods, the comparison of the obtained results to those of the reference centre, and the calculation of standardisation equations by regressing the quantitative results against those of the reference centre. As a cut-off indicative of protection against pertussis has not yet been defined, a parti…
Factors related to quality of ambulatory blood pressure monitoring in a pediatric population.
1999
To assess the factors related to the quality of ambulatory blood pressure monitoring in a pediatric population, we performed 24-h ambulatory blood pressure monitorings on 333 unselected children aged 3 to 18 years using a Spacelabs 90207 monitor. For each individual, the percentages of valid measurements (ratio between valid and total number of measurements, 76.4% +/-15.6%) and of successful measurements (percentage of valid preset measurements, 89.8% +/- 11.5%) were calculated. Two hundred eighty-one (84.1%) monitorings had a successful measurement rate of >80%. Two hundred thirteen (64%) were of excellent quality, as defined by the percentage of successful measurements being higher than o…
Repeated assessment of the Tower of Hanoi test: reliability and age effects.
2000
The purpose of this research was to analyze the effects of repeating an executive function test. Three versions of the Tower of Hanoi (TOH) test were repeated three times each, with test-retest intervals of 2 months. Two groups of children participated in the research (7.7 and 11.6 years, n = 22 and n = 28). Repeating the assessment improved the performance and decreased the total performance time in both of the groups. The older participants improved their performance faster than the younger ones. The reliability of all the scores, besides the error scores, seemed to be satisfactory after the first few assessments. The stability of the scores was maintained through all the assessments. Th…
Diurnal blood pressure curve in children and adolescents
1996
Objective To investigate the diurnal blood pressure curve in healthy normotensive children. Thirty-one children were re-examined after a median interval of 123 days in order to study the reproducibility of the diurnal profile. Subjects Twenty-four-hour ambulatory blood pressure monitoring and conventional blood pressure readings were obtained in 228 normotensive children, whose ages ranged from 6 to 16 years and of whom 116 were boys and 112 girls. Results The conventional blood pressure averaged 99+/-11/57+/-9 mmHg in boys and 98+/-12/56+/-9 mmHg in girls (means+/-SD); the corresponding 24 h pressures were 111+/-7/66+/-5 mmHg and 109+/-7/65+/-5 mmHg, respectively. Of the children, 83% had …
Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair: A Prospective Multi…
2020
Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-rel…
Prediction of response to disease modifying antirheumatic drugs in rheumatoid arthritis.
2010
Abstract Aim To investigate potential predictors of response to conventional DMARDs in RA. Methods Study design – 6-month follow-up prospective study. Participants RA patients with active disease. Intervention and follow-up Introduction of one DMARD. Response to treatment evaluated at 6 months (ACR20 criteria). Analysis Potential predictors of response, patients’ demographics, disease activity, percentages of PBMC subsets expressing P-gp, serum IL-1β, IL-6, IL-8, IL-10, IL-12, TNF-α levels, were evaluated using univariate and multivariate logistic regression analysis. ROC curve analyses were performed in order to obtain thresholds allowing the prediction of response. Results Forty-two patie…
Event-related potentials in newborns with and without familial risk for dyslexia: principal component analysis reveals differences between the groups
2003
Differences revealed by factor scores extracted by principal component analysis (PCA) from event-related potential (ERP) data of newborns with and without familial risk for dyslexia were examined and compared to results obtained by using original averaged ERPs. ERPs to consonant-vowel syllables (synthetic /ba/, /da/, /ga/; and natural /paa/, /taa/, /kaa/) were recorded from 26 at-risk and 23 control 1-7 day-old infants. The stimuli were presented equiprobably and with interstimulus intervals varying at random from 3,910 to 7,285 ms. Statistically significant between-group differences were found to be relatively similar irrespective of the methods of analysis (original ERPs vs. factor scores…
Cardiac kinematic parameters computed from video of in situ beating heart
2017
AbstractMechanical function of the heart during open-chest cardiac surgery is exclusively monitored by echocardiographic techniques. However, little is known about local kinematics, particularly for the reperfused regions after ischemic events. We report a novel imaging modality, which extracts local and global kinematic parameters from videos of in situ beating hearts, displaying live video cardiograms of the contraction events. A custom algorithm tracked the movement of a video marker positioned ad hoc onto a selected area and analyzed, during the entire recording, the contraction trajectory, displacement, velocity, acceleration, kinetic energy and force. Moreover, global epicardial veloc…
Accuracy, sensitivity and specificity of fine needle aspiration biopsy in salivary gland tumours: A retrospective study
2010
Objective: the aim of this study was to evaluate the diagnostic accuracy, sensitivity and specificity of fine needle aspiration biopsies (FNAB) of salivary gland tumours performed at the Erasto Gaertner Hospital over the course of a four year period. Study design: A retrospective study was carried out between 2001-2005 to review the cases of patients with salivary gland tumours who had undergone pre-operative FNAB and had been diagnosed during post-operative histopathology examination. Results: A total of 106 cases of salivary gland tumours were considered for this study, but 27 cases (25.5%) of the samples were considered unsatisfactory for analysis. the sensitivity, specificity and accura…
The accuracy of flexible spectral imaging colour enhancement for the diagnosis of gastric intestinal metaplasia
2014
Background Targeting biopsies on the basis of visual recognition of mucosal changes in the stomach instead of the currently accepted random biopsy sampling may be attractive. Aim The aim of this study was to evaluate the accuracy of endoscopic findings using flexible spectral imaging colour enhancement (FICE) for intestinal metaplasia (IM) in the gastric mucosa. Methods A consecutive cohort of 126 individuals aged over 50 years (27% men) was subjected to upper endoscopy using FICE. Histological assessment (per patient and per biopsy) was considered the gold standard to accuracy estimates. Results Histological assessment revealed IM in 50% of the individuals [OLGIM (operative link on gastric…