Search results for "revers"
showing 10 items of 1630 documents
Comparative study of solvation parameter models accounting the effects of mobile phase composition in reversed-phase liquid chromatography
2007
Solvation parameter models relate linearly compound properties with five fundamental solute descriptors (excess molar refraction, dipolarity/polarizability, effective hydrogen-bond acidity and basicity, and McGowan volume). These models are widely used, due to the availability of protocols to obtain the descriptors, good performance, and general applicability. Several approaches to predict retention in reversed-phase liquid chromatography (RPLC) as a function of these descriptors and mobile phase composition are compared, assaying the performance with a set of 146 organic compounds of diverse nature, eluted with acetonitrile and methanol. The approaches are classified in two groups: those t…
Performance of a Chromolith RP-18e column for the screening of β-blockers
2009
The chromatographic performance of a monolithic column (Chromolith RP-18e) was comprehensively examined in the isocratic separation of ten beta-blockers, using ACN-water mobile phases, and compared with the performance of three microparticulate RP columns manufactured with different types of silica: Spherisorb ODS-2, Kromasil C18 and XTerra MS C18. The comparison considered the analysis time, selectivity, peak shape (column efficiency and asymmetry) and resolution, and was extended to a wide range of mobile phase compositions. The Chromolith column showed good performance for the analysis of beta-blockers with regard to the packed columns. In terms of selectivity and analysis time, the grea…
Prediction of peak shape in hydro-organic and micellar-organic liquid chromatography as a function of mobile phase composition
2007
A simple model is proposed that relates the parameters describing the peak width with the retention time, which can be easily predicted as a function of mobile phase composition. This allows the further prediction of peak shape with global errors below 5%, using a modified Gaussian model with a parabolic variance. The model is useful in the optimisation of chromatographic resolution to assess an eventual overlapping of close peaks. The dependence of peak shape with mobile phase composition was studied for mobile phases containing acetonitrile in the presence and absence of micellised surfactant (micellar-organic and hydro-organic reversed-phase liquid chromatography, RPLC). In micellar RPLC…
A comparative study of the performance of acetonitrile and methanol in the multi-linear gradient separation of proteic primary amino acids
2006
The performance of the separation of proteic primary amino acids using multi-linear gradients of acetonitrile and methanol was studied under an experimental-design basis, using an Inertsil ODS-3 column and pre-column derivatization with o-phthaldialdehyde (OPA) and N-acetyl-l-cysteine (NAC). Elution strength, peak properties, resolution, and analysis time, were examined. The optimal separation was established through modeling, using information obtained from isocratic data. By optimizing the separation with gradients of increasing complexity, acceptable resolution was possible, being glycine/threonine the critical pair. Multi-criteria decision-making (Derringer desirabilities) was applied t…
Interpretive optimisation strategy applied to the isocratic separation of phenols by reversed-phase liquid chromatography with acetonitrile–water and…
2000
An optimisation protocol is presented for the resolution of complex mixtures in isocratic RPLC with binary mobile phases of organic solvent and water, which is based on the prediction of peak position and shape of the individual compounds. A good description of the retention was achieved through the application of statistical weights to the widely used linear or quadratic relationships between the logarithm of the retention factor (log k) and the organic solvent concentration in the mobile phase. The maximisation of the product of peak purities for each compound is shown as a competitive resolution strategy versus the worst value of a selectivity parameter. Peak purities allow one to associ…
Optimised procedures for the reversed-phase liquid chromatographic analysis of formulations containing tricyclic antidepressants.
2003
The chromatographic behaviour (retention, selectivity, peak shape and resolution) of seven tricyclic antidepressants (TCAs), amitryptiline, clomipramine, doxepin, imipramine, maprotiline, nortryptiline and trimipramine, was examined. Conventional unendcapped Cs and C18 columns and an endcapped XTerra MS C18 column recommended for the analysis of basic compounds were used together with acetonitrile-water and micellar sodium dodecylsulfate (SDS)-pentanol mobile phases. The two best combinations were XTerra C18/acetonitrile, which yielded the largest efficiencies and resolution, and C8/SDS-pentanol, which eliminated the peak tails that were still observed with the XTerra C18 column. Both the s…
Reversed phase liquid chromatography for the enantioseparation of local anaesthetics in polysaccharide-based stationary phases. Application to biodeg…
2020
[EN] A comprehensive study on the chiral separation of bupivacaine, mepivacaine, prilocaine and propanocaine with eight commercial polysaccharide-based chiral stationary phases (CSPs) in reversed phase conditions compatible with MS detection is performed. Methanol and acetonitrile are used as organic modifiers. Retention and resolution values obtained for each compound in the different CSPs and mobile phases are compared. The polysaccharide-based CSPs tested present different enantioselectivity towards the analytes. From the results, the experimental conditions for determining the enantiomers of bupivacaine, mepivacaine, prilocaine and propanocaine in saline aqueous samples using MS detecti…
Double Thermoresponsive Block Copolymers Featuring a Biotin End Group
2010
A poly(oligo(ethylene glycol) monomethyl ether methacrylate)-block-poly(N-isopropyl methacrylamide) (POEGMA-b-PNIPMAM) block copolymer with a biotin end group on the PNIPMAM block as a biotarget was synthesized as a model system for temperature-controlled polymer immobilization. The synthesis was based on RAFT polymerization followed by postpolymerization modification of an activated ester precursor block and an exchange of the dithioester end group within one step. NMR, differential scanning calorimetry (DSC), dynamic light scattering (DLS), and turbidimetry measurements were performed to investigate the stimulus-responsive properties. The double thermoresponsive POEGMA-b-PNIPMAM with biot…
Cast multibilayer films from polymerizable lipids
1987
The relation between neuronal chloride transporter activities, GABA inhibition, and neuronal activity
2020
Abstract The intracellular chloride concentration [Cl−]i in neurons is regulated by a set of transmembrane transporters, with the Cl−-loader NKCC1 and the Cl−-extruder KCC2 as most relevant members. The expression of these transporters is tightly regulated, with the general trend that KCC2 expression is low in immature neurons, which are thus characterized by a high [Cl−]i. As [Cl−]i is the main factor determining the polarity of GABAergic responses, such a high [Cl−]i is related to depolarizing GABAergic responses. However, depolarizing GABAergic responses are not per se excitatory, but can also contribute to shunting inhibition. The excitatory/inhibitory action of GABAergic responses is m…