Search results for "rippi"

showing 10 items of 74 documents

Determination of Cd, Cu, Pb and Zn content of infant formulas by differential pulse anodic stripping voltammetry (DPASV).

1994

The differential pulse anodic stripping voltammetry (DPASV) method described is based on the one reported by Hasse et al., but adapted to normal laboratory conditions. The values obtained in the estimation of the analytical parameters (linearity, detection and quantification limits, precision and accuracy) show that in the conditions described the method is sensitive enough, reliable and useful for determining these elements in infant formulas. A comparison between DPASV and atomic absorption spectroscopy (AAS) methods in the conditions described here shows that the former is less sensitive but that they are similar in precision. The cadmium, copper, lead and zinc contents of different type…

Accuracy and precisionAnalytical chemistrychemistry.chemical_elementZincNitric Acidlaw.inventionlawSpectrophotometryElectrochemistrymedicineHumansPolarographyCadmiummedicine.diagnostic_testSpectrophotometry AtomicInfantCopperAnodic stripping voltammetrychemistryMetalsSpainIndicators and ReagentsInfant FoodAtomic absorption spectroscopyPolarographyFood Science
researchProduct

Experimental and robust modeling approach for lead(II) uptake by alginate gel beads: influence of the ionic strength and medium composition.

2014

Abstract Systematic kinetic and equilibrium studies on the lead ions removal ability by Ca-alginate gel beads have been performed by varying several internal parameters, namely, number of gel beads, nature and composition of the ionic medium and pH, which allowed us to model a wastewater in order to closely reproduce the composition of a real sample. Moreover, the effects brought about the different ionic species present in the reacting medium have been evaluated. Differential Pulse Anodic Stripping Voltammetry (DP-ASV), has been systematically used to perform kinetic and equilibrium measurements over continuous time in a wide range of concentration. Kinetic and equilibrium data have been q…

Accuracy and precisionChemistryAnalytical chemistryIonic bondingKinetic energySurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsIonBiomaterialsAnodic stripping voltammetryColloid and Surface ChemistryIonic strengthAlginate gel beads Robust statistics Metal adsorption Wastewater treatment Ionic strength Differential Pulse Anodic Stripping Voltammetry Adsorption isotherms Adsorption kinetics Lead Heavy metalmedicineComposition (visual arts)Settore CHIM/01 - Chimica AnaliticaSwellingmedicine.symptomJournal of colloid and interface science
researchProduct

Effects of gait speed on stability of walking revealed by simulated response to tripping perturbation

2013

The objective of this work was to study stability of walking over a range of gait speeds by means of muscle-driven simulations. Fast walking has previously been related to high likelihood of falling due to tripping. Various measures of stability have shown different relationships between walking speed and stability. These measures may not be associated with tripping, so it is unclear whether the increase in likelihood of falling is explicable by an increase in instability. Here, stability with respect to a constant tripping perturbation was quantified as the immediate passive response of torso to the perturbation. Subject-specific muscle-driven simulations of eight young healthy subjects wa…

AdolescentAccelerationBiophysicsPerturbation (astronomy)Angular velocityModels BiologicalInstabilityControl theorymedicinePostural BalanceHumansComputer SimulationOrthopedics and Sports MedicineChildMuscle Skeletalta315GaitPostural BalanceMathematicsta114ElectromyographyRehabilitationMathematical analysisTorsoTorsoBiomechanical PhenomenaPreferred walking speedmedicine.anatomical_structureTrippingAccidental FallsMaximahuman activitiesGait and Posture
researchProduct

Chemical Properties of Element 105 in Aqueous Solution: Halide Complex Formation and Anion Exchange into Triisoctyl Amine

2017

Studies of the halide complexation of element 105 in aqueous solution were performed on 34-s 262Ha produced in the 249Bk(18-O,5n) reaction. The 262Ha was detected by measuring the fission and alpha activities associated with its decay and the alpha decays of its daughter, 4.3-s 258Lr. Time-correlated pairs of parent and daughter alpha particles provided a unique identification of the presence of 262Ha. About 1600 anion exchange separations of 262Ha from HCl and mixed HC1/HF solutions were performed on a one-minute time scale. Reversed-phase micro-chromatographic columns incorporating triisooctyl amine (TIOA) on an inert support were used in the computer-controlled liquid chromatography appa…

AdsorptionAqueous solutionIon exchangeStripping (chemistry)ChemistryOxohalide540 ChemistryInorganic chemistry570 Life sciences; biologyHalideAmine gas treatingAlpha particlePhysical and Theoretical Chemistryract
researchProduct

An assessment of the human nail plate pH.

2010

<i>Purpose of Study:</i> To measure the pH of the surface of healthy nail plates. <i>Procedures:</i> The surface pH of human fingernails and big toenails was measured in vivo using a skin pH meter. The influence of washing, anatomical site (fingers/toes), side (left/right), digit (digits 1–5) and gender was determined. The pH of the nail interior was also measured. <i>Results:</i> The pH of the nail plate surface was around 5, with toenails having a significantly higher pH than fingernails. Immediately after hand washing, the nail surface pH increased significantly, from pH 5.1 ± 0.4 to 5.3 ± 0.5. However, this was not sustained with time, and the pH retu…

AdultMaleWashingTape strippingPhysiologyNailDermatologyFingersYoung AdultmedicineHumansProspective Studiesskin and connective tissue diseasesAgedPharmacologyBaseline valuesChromatographyintegumentary systempHChemistryGenderGeneral MedicineAnatomyNail plateHydrogen-Ion ConcentrationMiddle AgedToesSurface phmedicine.anatomical_structureNailsSettore CHIM/09 - Farmaceutico Tecnologico ApplicativoNail (anatomy)FemaleSkin pharmacology and physiology
researchProduct

Comparison of DMEK and DSAEK in Eyes With Endothelial Decompensation After Previous Penetrating Keratoplasty.

2021

PURPOSE Posterior lamellar keratoplasty is increasingly applied in patients with endothelial decompensation after penetrating keratoplasty (PK). The aim of this study was to compare the results of Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) after PK. METHODS In this retrospective study, clinical data of 30 patients who received DMEK (n = 19) or DSAEK (n = 11) for endothelial decompensation after PK were evaluated. All lamellar keratoplasties were performed at the Department of Ophthalmology at University Hospital Mainz, Germany. Primary end point included best-corrected visual acuity, and secondary end points included e…

AdultMalemedicine.medical_specialtyVisual acuityDescemet membraneVisual AcuityCell CountCorneal DiseasesYoung AdultOphthalmologymedicineHumansDecompensationIn patientPostoperative PeriodAgedRetrospective StudiesAged 80 and overGraft rejectionbusiness.industryGraft SurvivalEndothelial CellsCorneal Endothelial Cell LossMiddle AgedUniversity hospitalDescemet stripping automated endothelial keratoplastyEndothelial cell densityOphthalmologyFemalemedicine.symptombusinessDescemet Stripping Endothelial KeratoplastyKeratoplasty PenetratingCornea
researchProduct

Digestion-free determination of heavy metals (Pb, Cd, Cu) in honey using anodic stripping differential pulse voltammetry and potentiometric stripping…

1995

Experiments have been carried out to assess the potential of differential pulse voltammetry and potential stripping analysis for determining Pb, Cu and Cd directly in dissolved honey samples using a flow-through cell. With the hanging mercury drop electrode Pb alone can be determined only if the electrode is first modified in-situ with Triton X 100 to increase the separation between the Pb peak and a broad, interfering adsorption peak which overlaps the Cu peak. If the (more sensitive) thin film mercury electrode is used the interference encountered is less so also Cu and Cd can be determined. With potentiometric stripping analysis Cu and Pb can be determined using normal procedures. The de…

Anodic stripping voltammetryAdsorptionStripping (chemistry)ChemistryHanging mercury drop electrodePotentiometric titrationOxidizing agentAnalytical chemistryfood and beveragesDifferential pulse voltammetryDropping mercury electrodeBiochemistryAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

Antibacterial PEGylated Solid Lipid Microparticles for Cosmeceutical Purpose: Formulation, Characterization, and Efficacy Evaluation

2020

The development of efficacious means of delivering antioxidant polyphenols from natural sources for the treatment of skin diseases is of great interest for many cosmetic and pharmaceutical companies. Resveratrol (RSV) and Limonene (LIM) have been shown to possess good anti-inflammatory and antibacterial properties against Staphylococcus aureus infections responsible for many skin disorders, such as acne vulgaris. In this study, solid lipid microparticles are designed as composite vehicles capable of encapsulating a high amount of trans-RSV and enhancing its absorption through the stratum corneum. A microparticulate system based on mixture of PEGylate lipids, long-chain alcohols and LIM is a…

Antioxidanttape-strippingmedicine.medical_treatment02 engineering and technologyResveratrolLabrasolSettore BIO/19 - Microbiologia Generale01 natural scienceslcsh:Technologyporcine earchemistry.chemical_compoundlipid microsphereGeneral Materials ScienceAcnemedia_commonlcsh:QC120-168.851-Hexadecanol021001 nanoscience & nanotechnologyAntimicrobialmedicine.anatomical_structure0210 nano-technologyCosmeceuticallcsh:TK1-9971Drugmedia_common.quotation_subjectAbsorption (skin)Staphylococcus aureus ATCC 25923Articlelipid microspheresmedicineStratum corneumlcsh:Microscopyantimicrobial activityporcine earslcsh:QH201-278.5010405 organic chemistrylcsh:Tmedicine.diseaseCombinatorial chemistry0104 chemical scienceschemistry<i>Staphylococcus aureus</i> ATCC 25923lcsh:TA1-2040Settore CHIM/09 - Farmaceutico Tecnologico ApplicativoResveratrolsolid lipid microparticlelcsh:Descriptive and experimental mechanicssolid lipid microparticleslcsh:Electrical engineering. Electronics. Nuclear engineeringlcsh:Engineering (General). Civil engineering (General)LimoneneMaterials
researchProduct

A novel thermodynamic approach for the complexation study of toxic metal cations by a landfill leachate

2018

Landfill leachates can contaminate nearby aquifers. The hazards deriving from this contamination also depend on the chemical speciation of various contaminants. A novel approach is proposed here to face this problem from a chemical thermodynamics point of view. The complexing ability of the soluble fraction of a landfill leachate (collected from Bellolampo, Palermo, Italy) towards Pb2+, Cd2+ and Cu2+ has been investigated at T = 298.15 K in NaClaq at I = 0.1 mol dm−3. The soluble fraction of the landfill leachate was first characterized by different analytical techniques. Then, its acid–base properties were studied by ISE-H+ potentiometric titrations and modelled by the so-called diprotic-l…

Aqueous solutionChemistryPotentiometric titrationInorganic chemistry02 engineering and technologyGeneral Chemistry010501 environmental sciences021001 nanoscience & nanotechnology01 natural sciencesCatalysisMetalAnodic stripping voltammetryLandfill leachate sequestering ability complexation toxic metalsChemical thermodynamicsSequestrantvisual_artMaterials Chemistryvisual_art.visual_art_mediumTitrationSettore CHIM/01 - Chimica AnaliticaLeachate0210 nano-technology0105 earth and related environmental sciences
researchProduct

Deteriorated stabilization of walking in individuals with spastic cerebral palsy revealed by a simulated tripping perturbation

2014

Abstract. The aim of this study was to make use of a pr eviously introduced method of a simulated tripping perturbation to examine stability of walking in individuals with and with out cerebral palsy. This tripping perturbation is a forward-dynamics analys is, and it works so that in a subjec t-specific muscle-driven simulation of walking, created from experimental gait data, a force is applied to the swin g-foot, and resulting changes in the kinematics are observed. Here, changes in the fore-aft position of the trunk were analyzed. Subjects were 10 children with spastic diplegic cerebral palsy and eight un impaired children walking at their self-sel ected speed. Several tripping perturbati…

CP-oireyhtymäEmbryologymedicine.medical_specialtyta114Perturbation (astronomy)Cell BiologyKinematicsSwingmedicine.diseaseTrunkGaitspastic cerebral palsyCerebral palsywalkingPhysical medicine and rehabilitationSpastic cerebral palsyTrippingmedicinePhysical therapyAnatomyta315human activitiesDevelopmental BiologyMathematics
researchProduct