Search results for "sage"
showing 10 items of 1373 documents
Influence of different CyA formulations and calcium channel blocker phenyhidine regimens on intracellular (erythrocyte) calcium levels after kidney t…
1997
Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning
2008
Purpose: According to the GYN GEC-ESTRO Recommendations, MRI is needed with the modality of T2 weighted. CT-MR compatible tandem Plus colpostats (T/C) (Nucletron) is widely used in cervical brachytherapy. The major challenge of MRI is the lack of dummy catheters. Therefore, an additional imaging modality is usually required. One disadvantage of sliced-based reconstruction is that resolution in longitudinal directions can be affected by the slice thickness. The aim of this study is to present a modified T/C applicator in which the catheter visibility is significantly improved. Methods and materials: A modification to the existing T/C applicator has been made available, increasing the cathete…
The value of high resolution CT in the diagnosis of meniscal lesions of the knee
1991
We report on 50 patients who had meniscal pathology and were given computed tomographic (CT) scans. Our diagnostic accuracy was approximately 92%. We believe that CT is a good method of screening these patients prior to using a much more expensive method, such as magnetic resonance imaging or diagnostic arthroscopy.
OP0090 THE OCCURRENCE OF SUBCLINICAL AND CLINICAL ATHEROSCLEROSIS IN RHEUMATOID ARTHRITIS, RESULTS FROM THE 3-YEAR, MULTICENTER, PROSPECTIVE, OBSERVA…
2019
Background The systemic inflammatory process and the “traditional” cardiovascular (CV) risk factors could synergize the enhancement of CV burden in rheumatoid arthritis (RA) [1]. Objectives To assess the occurrence and the predictive factors of subclinical and clinical atherosclerosis in patients with RA. Methods During 2015, consecutive patients, admitted to Italian Rheumatology Units, were assessed in GIRRCS (Gruppo Italiano di Ricerca in Reumatologia Clinica e Sperimentale) cohort [2]. After that, patients were followed-up in a 3-year, prospective, observational study, assessing the occurrence of subclinical (carotid and/or peripheral arteries atherosclerotic lesions detected by ultrasou…
A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model
2007
A computer-aided detection (CAD) system for the selection of lung nodules in computer tomography (CT) images is presented. The system is based on region growing (RG) algorithms and a new active contour model (ACM), implementing a local convex hull, able to draw the correct contour of the lung parenchyma and to include the pleural nodules. The CAD consists of three steps: (1) the lung parenchymal volume is segmented by means of a RG algorithm; the pleural nodules are included through the new ACM technique; (2) a RG algorithm is iteratively applied to the previously segmented volume in order to detect the candidate nodules; (3) a double-threshold cut and a neural network are applied to reduce…
The treatment of severe self-injurious behavior through sensory stimulation: A case report
2016
Self-injurious behavior of an institutionalized man with profound intellectual disability was treated with a daily 15-min sensory stimulation program, which consisted of moving the arms and hands of the participant, swinging his body, and massage. The frequency of self-injurious behavior was measured in 10-min sessions. Using a reversal design, it was shown that sensory stimulation decreased the participant’s self-hitting behavior significantly, both in intensity and in frequency. Sensory stimulation is recommended for use in those cases in which functional analysis has shown that self-injury may be reinforced by its sensory consequences.
Effects of Far Infrared Heat on Recovery in Power Athletes
2015
Effects of Far Infrared Heat on Recovery in Power Athletes Objective: The purpose of this study was to investigate the effects of the far infrared (FIR) heat on the recovery of the power athletes during the 5-day intensive training period. Methods: The experimental group acted also as its own control group and it consisted of ten national level male athletes (22.3 ± 4.5 years) from power events. Training consisted of strength-, power-, and technique sessions. Performance tests included isometric strength tests, a countermovement jump (CMJ) and a Wingate 30 s test. Serum concentration of testosterone, cortisol, sex hormone binding globulin, high-sensitivity C-reactive protein and creatinekin…
Broad-beam transmission data for new brachytherapy sources, Tm-170 and Yb-169
2005
The characteristics of the radionuclides (170)Tm and (169)Yb are highly interesting for their use as high dose-rate brachytherapy sources. The introduction of brachytherapy equipment containing these sources will lead to smaller required thicknesses of the materials used in radiation protection barriers compared with the use of conventional sources such as (192)Ir and (137)Cs. The purpose of this study is to determine the required thicknesses of protection material for the design of the protecting walls. Using the Monte Carlo method, transmission data were derived for broad-beam geometries through lead and concrete barriers, from which the first half value layer and tenth value layer are ob…
Effect of chest compressions only during experimental basic life support on alveolar collapse and recruitment
2007
Summary Aim The importance of ventilatory support during cardiac arrest and basic life support is controversial. This experimental study used dynamic computed tomography (CT) to assess the effects of chest compressions only during cardiopulmonary resuscitation (CCO-CPR) on alveolar recruitment and haemodynamic parameters in porcine model of ventricular fibrillation. Materials and methods Twelve anaesthetized pigs (26±1kg) were randomly assigned to one of the following groups: (1) intermittent positive pressure ventilation (IPPV) both during basic life support and advanced cardiac life support, or (2) CCO during basic life support and IPPV during advanced cardiac life support. Measurements w…
Verification of a commercial implementation of the Macro-Monte-Carlo electron dose calculation algorithm using the virtual accelerator approach.
2009
Abstract In this work, the accuracy of the implementation of the Macro Monte Carlo electron dose calculation algorithm into the radiation therapy treatment planning system Eclipse is evaluated. This implementation – called eMC – uses a particle source based on the Rotterdam Initial Phase-Space model. A three-dimensional comparison of eMC calculated dose to dose distributions resulting from full treatment head simulations with the Monte Carlo code package EGSnrc is performed using the ‘virtual accelerator’ approach. Calculated dose distributions are compared for a homogeneous tissue equivalent phantom and a water phantom with air and bone inhomogeneities. The performance of the eMC algorithm…